Gas hold-up in a reactor with dual system of impellers

被引:0
|
作者
Karcz, J [1 ]
Siciarz, R [1 ]
Bielka, I [1 ]
机构
[1] Tech Univ Szczecin, Fac Chem Engn, Dept Chem Engn, PL-71065 Szczecin, Poland
来源
CHEMICAL PAPERS | 2004年 / 58卷 / 06期
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Results of experimental studies of gas hold-up in a liquid stirred mechanically in a reactor, which was equipped with double stirrers on a common shaft, are presented. Coalescing and noncoalescing gas-liquid systems were tested. The measurements were carried out for aqueous solutions of glucose and glucose sirup, as well as for different configurations of dual high-speed impellers. Stirred tank with inner diameter D = 0.288 m was filled with a liquid up to the height H = 2D. Experimental studies of gas hold-up in the coalescing and noncoalescing gas-liquid systems stirred using dual system of high-speed impellers show that gas hold-up W for the noncoalescing systems is considerably higher than that for the coalescing ones. The configuration of dual system of impellers used in the study slightly affects only gas hold-up and this effect can be neglected. The dependence of gas hold-up W on the specific power consumption P-g/V-L and superficial gas velocity w(og) for coalescing and noncoalescing systems can be described by means of eqns (2) and (3), respectively.
引用
收藏
页码:404 / 409
页数:6
相关论文
共 50 条
  • [1] Gas Hold-Up in Vessel with Dual Impellers and Different Baffles
    Major-Godlewska, Marta
    Cudak, Magdalena
    [J]. ENERGIES, 2022, 15 (22)
  • [2] Gas hold-up in stirredd vessels with two impellers
    Kamienski, J
    Niznik, J
    [J]. INZYNIERIA CHEMICZNA I PROCESOWA, 2001, 22 (3C): : 591 - 596
  • [3] GAS HOLD-UP IN A BUBBLE COLUMN WITH CONE TURBINE IMPELLERS
    ZIELINSKI, M
    [J]. CHEMISCHE TECHNIK, 1988, 40 (04): : 160 - 163
  • [4] Hold-up and gas-liquid mass transfer performance of modified Rushton turbine impellers
    Orvalho, SCP
    Vasconcelos, JMT
    Alves, SS
    [J]. 10TH EUROPEAN CONFERENCE ON MIXING, 2000, : 461 - 468
  • [5] Experimental analysis of gas hold-up for gas-liquid system agitated in a vessel equipped with two impellers and vertical tubular baffles
    Major-Godlewska, Marta
    Radecki, Dawid
    [J]. POLISH JOURNAL OF CHEMICAL TECHNOLOGY, 2018, 20 (01) : 7 - 12
  • [6] Consistency of gas hold-up determinations
    Gonzalez, FR
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) : 165 - 172
  • [7] Ways of Estimating the Hold-up Time of a Gas Chromatographic System
    V. E. Shiryaeva
    T. P. Popova
    A. Yu. Kanat’eva
    A. A. Korolev
    A. A. Kurganov
    [J]. Russian Journal of Physical Chemistry A, 2019, 93 : 2291 - 2296
  • [8] GAS HOLD-UP MEASUREMENTS IN BIOREACTORS
    HOFMEESTER, JJM
    [J]. TRENDS IN BIOTECHNOLOGY, 1988, 6 (01) : 19 - 22
  • [9] GAS HOLD-UP IN AERATED REACTORS
    STPETROV, P
    PETKOV, AA
    PANAYOTOVA, EN
    DIMITROV, DI
    POPANGELOVA, MP
    [J]. CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1979, 17 (03): : 169 - 171
  • [10] Particle hold-up in two fluidized reactor system with two loopseals
    Yi, CK
    Cho, SH
    Bae, DH
    Shun, D
    Jin, GT
    Son, JE
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2001, 34 (02) : 269 - 273