Differences in articular track area of posterior-stabilized and cruciate-retaining retrieved total knee implants

被引:0
|
作者
Bradley, MP
Mayor, MB
Collier, JP
机构
[1] Brown Univ, Rhode Isl Hosp, Sch Med, Dept Orthoped, Providence, RI 02903 USA
[2] Dartmouth Hitchcock Med Ctr, Dept Orthoped, Lebanon, NH 03766 USA
[3] Dartmouth Coll, Thayer Sch Engn, Dartmouth Biomed Engn Ctr, Hanover, NH 03755 USA
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Press-fit condylar total knee arthroplasties removed at revision surgery from 27 knees were examined. Fourteen of the implants: were posterior stabilized press-fit condylar systems and 13 were cruciate-retaining press-fit condylar systems. The articular track areas were examined using a digital; camera and manual measurements. Findings revealed the track area in posterior-stabilized implants (93%) was larger than in cruciate-retaining implants (59%). Mean posterior distance ratio of the articular track from the posterior limit of the polyethylene was 2% (.08.cm) for posterior-stabilized implants versus 23% (:97 cm) for cruciate-retaining implants: No differences in wear rating were noted. The pattern of. articular contact in cruciate-retaining knees demonstrated little migration of the femoral contact surface across the tibial polyethylene plateau.
引用
收藏
页码:1273 / 1278
页数:6
相关论文
共 50 条
  • [1] Outcomes of Posterior-Stabilized Compared with Cruciate-Retaining Total Knee Arthroplasty
    Longo, Umile Giuseppe
    Ciuffreda, Mauro
    Mannering, Nicholas
    D'Andrea, Valerio
    Locher, Joel
    Salvatore, Giuseppe
    Denaro, Vincenzo
    JOURNAL OF KNEE SURGERY, 2018, 31 (04) : 321 - 340
  • [2] Posterior-stabilized and cruciate-retaining total knee replacement - A randomized study
    Clark, CR
    Rorabeck, CH
    MacDonald, S
    MacDonald, D
    Swafford, J
    Cleland, D
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 208 - 212
  • [3] Cruciate-retaining versus posterior-stabilized total knee arthroplasty: The argument for posterior cruciate substitution
    Tria, AJ
    ARTHROPLASTY 2000: RECENT ADVANCES IN TOTAL JOINT REPLACEMENT, 2001, : 205 - 209
  • [4] What to Know for Selecting Cruciate-Retaining or Posterior-Stabilized Total Knee Arthroplasty
    Song, Sang Jun
    Park, Cheol Hee
    Bae, Dae Kyung
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (02) : 142 - 150
  • [5] Soft Tissue Tension in Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty
    Matsumoto, Tomoyuki
    Muratsu, Hirotsugu
    Kubo, Seiji
    Matsushita, Takehiko
    Kurosaka, Masahiro
    Kuroda, Ryosuke
    JOURNAL OF ARTHROPLASTY, 2011, 26 (05): : 788 - 795
  • [6] Posterior-stabilized versus cruciate-retaining total knee arthroplasty - Balancing the gap
    Tanzer, M
    Smith, K
    Burnett, S
    JOURNAL OF ARTHROPLASTY, 2002, 17 (07): : 813 - 819
  • [7] Kinematic analysis of kneeling in cruciate-retaining and posterior-stabilized total knee arthroplasties
    Hamai, Satoshi
    Miura, Hiromasa
    Higaki, Hidehiko
    Matsuda, Shuichi
    Shimoto, Takeshi
    Sasaki, Kousuke
    Yoshizumi, Masaaki
    Okazaki, Ken
    Tsukamoto, Nobuaki
    Iwamoto, Yukihide
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (04) : 435 - 442
  • [8] Posterior Cruciate-Retaining Versus Posterior-Stabilized Total Knee Arthroplasty: A Meta-Analysis
    Bercik, Michael J.
    Joshi, Ashish
    Parvizi, Javad
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03): : 439 - 444
  • [9] Effect of posterior-stabilized and cruciate-retaining implants on three-dimensional kinematic characteristics after total knee arthroplasty
    Gu, Cheng
    Luo, Xuming
    Liu, Hailong
    Yu, Baoxi
    Fu, Ming
    Luo, Weiliang
    JOINT DISEASES AND RELATED SURGERY, 2025, 36 (01): : 3 - 14
  • [10] Posterior cruciate-retaining versus posterior-stabilized total knee arthroplasty for osteoarthritis with severe varus deformity
    Unkar, Ethem Ayhan
    Ozturkmen, Yusuf
    Sukur, Erhan
    Carkci, Engin
    Mert, Murat
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (02) : 95 - 99