Stator voltage harmonics and unbalance compensation of the sensorless standalone doubly fed induction generator

被引:1
|
作者
Iwanski, Grzegorz [1 ]
Pura, Piotr [1 ]
Luszczyk, Tomasz [1 ]
Szypulski, Mateusz [1 ]
机构
[1] Warsaw Univ Technol, Inst Control & Ind Elect, Warsaw, Poland
关键词
Renewable energy; Doubly fed induction machine; Nonlinear load; Standalone generator; Unbalanced load; Voltage control; DIRECT POWER-CONTROL; WIND TURBINES; MACHINE; PERFORMANCE; SYSTEM;
D O I
10.1108/COMPEL-04-2014-0083
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Purpose - Doubly fed induction generator (DFIG) is widely used in wind energy conversion systems and it can operate with other primary movers. The purpose of this paper is to focus on the standalone operation of DFIG which may expand the area of possible applications and increase capabilities of the generation system in terms of power quality. Design/methodology/approach - Synthesis of the control method was preceded by analysis of mathematical model of the machine. The control method based on the negative sequence and high harmonics extraction has been developed and verified in the laboratory unit. Control of the fundamental frequency component uses neither rotor speed nor position sensors. Findings - The original method allows to compensate negative sequence and high harmonics of the generated voltage. At the same time, due to the active filtering capability of the grid side converter, the stator phase current shape is close to sine wave. Thus, it is seen by the machine as a linear load, what eliminates the electromagnetic torque ripples. Practical implications - The system and control method can be applied in variable speed generation systems, e. g. wind turbines or diesel engines operating in the standalone mode. Originality/value - Although the selective compensation of negative sequence and harmonics are known in the literature, until now the methods have been verified for the system with a rotor position sensor. Moreover, the stator current feed-forward improving the transient properties, as well as results of transient states caused by the load step change, have not been proposed in publications.
引用
收藏
页码:1741 / 1760
页数:20
相关论文
共 50 条
  • [1] A Novel Sensorless Control Strategy of Doubly Fed Induction Generator Based on Stator Voltage
    Hao, Xin
    Zhang, Chong Wei
    Zhang, Xing
    Yu, Yong
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [2] Enhanced compensation strategy of voltage harmonics for Doubly-Fed induction generator
    Liao, Kai
    Pang, Bo
    Yang, Jianwei
    Jin, Xiao
    Chen, Bo
    He, Zhengyou
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 148
  • [3] Compensation Strategy of Wideband Voltage Harmonics for Doubly-Fed Induction Generator
    Liao, Kai
    Pang, Bo
    Yang, Jianwei
    He, Zhengyou
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2023, 38 (01) : 674 - 684
  • [4] Model Predictive Sensorless Control of Standalone Doubly Fed Induction Generator
    Bayhan, Sertac
    Abu-Rub, Haitham
    [J]. IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 2166 - 2172
  • [5] Robust Observer Design for Sensorless Voltage and Frequency Control of a Doubly Fed Induction Generator in Standalone Mode
    Mondal, Prosenjit
    Malakar, Mridul Kanti
    Tripathy, Praveen
    Krishnaswamy, S.
    Saha, Ujjwal K.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (02) : 844 - 854
  • [6] Harmonics and Unbalance Compensation of the Generated Voltage in a Standalone DFIG
    Iwanski, Grzegorz
    Pura, Piotr
    Luszczyk, Tomasz
    Szypulski, Mateusz
    [J]. 2013 8TH INTERNATIONAL CONFERENCE AND EXHIBITION ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2013,
  • [7] Analysis of stator voltage observers for a Doubly Fed Induction Generator
    Thomsen, Soenke
    Rothenhagen, Kai
    Fuchs, Friedrich W.
    [J]. 2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 1861 - 1869
  • [8] An Autonomous Frequency and Voltage Controller for Standalone Doubly Fed Induction Generator
    Bayhan, Sertac
    Abu-Rub, Haitham
    [J]. 2015 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2015, : 138 - 142
  • [9] Compensation of network voltage unbalance using doubly fed induction generator-based wind farms
    Wang, Y.
    Xu, L.
    Williams, B. W.
    [J]. IET RENEWABLE POWER GENERATION, 2009, 3 (01) : 12 - 22
  • [10] Improved Sensorless Direct Voltage Control of Standalone Doubly-Fed Induction Generator Feeding Nonlinear loads
    Yu, Kailiang
    Xu, Wei
    Liu, Yi
    Zhang, Songyang
    [J]. 2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 1674 - 1679