Clinical outcomes among low-titer group O whole blood recipients compared to recipients of conventional components in civilian trauma resuscitation

被引:97
|
作者
Seheult, Jansen N. [1 ]
Anto, Vincent [2 ]
Alarcon, Louis H. [3 ,4 ]
Sperry, Jason L. [3 ,4 ]
Triulzi, Darrell J. [1 ,5 ]
Yazer, Mark H. [1 ,5 ]
机构
[1] Univ Pittsburgh, Dept Pathol, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Sch Med, Pittsburgh, PA 15260 USA
[3] Univ Pittsburgh, Dept Surg, Pittsburgh, PA 15260 USA
[4] Univ Pittsburgh, Dept Crit Care Med, Pittsburgh, PA 15260 USA
[5] Inst Transfus Med, 3636 Blvd Allies, Pittsburgh, PA 15220 USA
关键词
ANTI-D; TRANSFUSION; PLASMA; SAFETY;
D O I
10.1111/trf.14779
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The serological safety of transfusing = 4 units of low titer group O whole blood (LTOWB) in civilian trauma patients has been demonstrated. This study investigated clinical outcomes of LTOWB recipients compared to patients who received only conventional blood components during their resuscitation. STUDY DESIGN AND METHODS: A retrospective analysis of trauma patients' medical records who received LTOWB during the first 24 hours of their admission was performed. Using a 12- parameter propensity matching strategy, LTOWB recipients were matched to other patients who received at least one red blood cell (RBC) unit during their first 24 hours of admission but not LTOWB. The primary outcomes were mortality and blood use. RESULTS: A total of 135 patients who received LTOWB (median 2 units) were matched to 135 patients who received conventional components. There were no significant differences in the matching parameters between the groups. There were no significant differences in outcomes between the conventional component and LTOWB groups: median (interquartile range) in- hospital mortality, 24.4% vs. 18.5% (respectively, p = 0.24); 24- hour mortality, 12.6% vs. 8.9% (respectively, p = 0.33). The hospital and intensive care unit lengths of stay were not significantly different between groups. The median number of RBC units transfused, including the contribution from the LTOWB, was not significantly different between the groups. The time to normalization of elevated plasma lactate levels tended to be shorter among the LTOWB recipients compared to the conventional component recipients (median 8.1 [ 3.7- 15.4] hr vs. 13.2 [ 4.4- 26.8] hr, respectively, p = 0.05). CONCLUSION: The LTOWB recipients had similar clinical outcomes compared to recipients of conventional component therapy.
引用
收藏
页码:1838 / 1845
页数:8
相关论文
共 50 条
  • [1] The use of low-titer group O whole blood for the resuscitation of civilian trauma patients in 2018
    Yazer, Mark H.
    Spinella, Philip C.
    TRANSFUSION, 2018, 58 (11) : 2744 - 2746
  • [2] The rebirth of the cool: a narrative review of the clinical outcomes of cold stored low titer group O whole blood recipients compared to conventional component recipients in trauma
    Dishong, Devin
    Cap, Andrew P.
    Holcomb, John B.
    Triulzi, Darrell J.
    Yazer, Mark H.
    HEMATOLOGY, 2021, 26 (01) : 601 - 611
  • [3] Injured recipients of low-titer group O whole blood have similar clinical outcomes compared to recipients of conventional component therapy: A single-center, retrospective study
    Yazer, Mark H.
    Freeman, Andrew
    Harrold, Ian M.
    Anto, Vincent
    Neal, Matthew D.
    Triulzi, Darrell J.
    Sperry, Jason L.
    Seheult, Jansen N.
    TRANSFUSION, 2021, 61 (06) : 1710 - 1720
  • [4] Safety and efficacy of low-titer O whole blood resuscitation in a civilian level I trauma center
    Bohan, Phillip M. Kemp
    Mccarthy, Patrick M.
    Wall, Morgan E.
    Adams, Alexandra M.
    Chick, Robert C.
    Forcum, Jason E.
    Radowsky, Jason S.
    How, Remealle A.
    Sams, Valerie G.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2021, 91 (2S): : S162 - S168
  • [5] Survey of group A plasma and low-titer group O whole blood use in trauma resuscitation at adult civilian level 1 trauma centers in the US
    Yazer, Mark H.
    Spinella, Philip C.
    Anto, Vincent
    M. Dunbar, Nancy
    TRANSFUSION, 2021, 61 (06) : 1757 - 1763
  • [6] The Efficacy of Low-Titer Group O Whole Blood Compared With Component Therapy in Civilian Trauma Patients: A Meta-Analysis
    Morgan, Katrina M.
    Abou Khalil, Elissa
    Feeney, Erin V.
    Spinella, Philip C.
    Lucisano, Amelia C.
    Gaines, Barbara A.
    Leeper, Christine M.
    CRITICAL CARE MEDICINE, 2024, 52 (07) : e390 - e404
  • [7] An evaluation of methods for producing low-titer group O whole blood to support military trauma resuscitation
    Belin, Tamara R.
    Yazer, Mark H.
    Meledeo, Michael A.
    Fahie, Roland L.
    Malloy, Wilbur W.
    Stubbs, James R.
    Cap, Andrew P.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2017, 82 (06): : S79 - S86
  • [8] Survey to inform trial of low-titer group O whole-blood compared to conventional blood components for children with severe traumatic bleeding
    Kolodziej, Julia
    Leonard, Julie C.
    Josephson, Cassandra D.
    Gaines, Barbara A.
    Wisniewski, Stephen R.
    Yazer, Mark H.
    Spinella, Philip C.
    TRANSFUSION, 2021, 61 : S43 - S48
  • [9] An international survey on the use of low titer group O whole blood for the resuscitation of civilian trauma patients in 2020
    Yazer, Mark H.
    Spinella, Philip C.
    TRANSFUSION, 2020, 60 : S176 - S179
  • [10] Resuscitative practices and the use of low-titer group O whole blood in pediatric trauma
    Morgan, Katrina M.
    Leeper, Christine M.
    Yazer, Mark H.
    Spinella, Philip C.
    Gaines, Barbara A.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2023, 94 (1S): : S29 - S35