Repeatability of 3D gait kinematics obtained from an electromagnetic tracking system during treadmill locomotion

被引:56
|
作者
Mills, Peter M. [1 ]
Morrison, Steven
Lloyd, David G.
Barrett, Rod S.
机构
[1] Univ Western Australia, Sch Human Movement & Exercise Sci, Nedlands, WA 6009, Australia
[2] Griffith Univ, Sch Physiotherapy & Exercise Sci, Nathan, Qld 9726, Australia
[3] Griffith Univ, Appl Cognit Neurosci Res Ctr, Nathan, Qld 9726, Australia
关键词
kinematics; electromagnetic tracking system; gait; repeatability; treadmill locomotion;
D O I
10.1016/j.jbiomech.2006.06.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this paper was to describe a technique that enables three-dimensional (31)) gait kinematics to be obtained using an electromagnetic tracking system, and to report the intra-trial, intra-day/inter-tester and inter-day/intra-tester repeatability of kinematic gait data obtained using this technique. Ten able-bodied adults underwent four gait assessments; the same two testers tested each subject independently on two different days. Gait assessments were conducted on a custom-built long-bed treadmill with no metal components between the rollers. Each gait assessment involved familiarisation to treadmill walking, subject anatomical and functional calibration, and a period of steady-state treadmill walking at a self-selected speed. Following data collection, 3D joint kinematics were calculated using the joint coordinate system approach. 3D joint angle waveforms for 10 left and right strides were extracted and temporally normalised for each trial. Intra-trial, intra-day/inter-tester and inter-day/intra-tester repeatability of the temporally normalised kinematic waveforms were quantified using the coefficient of multiple determination (CMD). CMDs for joint kinematics averaged 0.942 intra-trial, 0.849 intra-day/inter-tester and 0.773 inter-day/intra-tester. In general, sagittal plane kinematics were more repeatable than frontal or transverse plane kinematics, and kinematics at the hip were more repeatable than at the knee or ankle. The level of repeatability of kinematic gait data obtained during treadmill walking using this protocol was equal or superior to that reported previously for overground walking using image-based protocols. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1504 / 1511
页数:8
相关论文
共 50 条
  • [1] Repeatability of back kinematics in horses during treadmill locomotion
    Faber, M
    Johnston, C
    van Weeren, PR
    Barneveld, A
    [J]. EQUINE VETERINARY JOURNAL, 2002, 34 (03) : 235 - 241
  • [2] Validation of 3D Knee Kinematics during Gait on Treadmill with an Instrumented Knee Brace
    Reneaud, Nicolas
    Zory, Raphael
    Guerin, Olivier
    Thomas, Luc
    Colson, Serge S. S.
    Gerus, Pauline
    Chorin, Frederic
    [J]. SENSORS, 2023, 23 (04)
  • [3] 3D analysis of limbs kinematics during treadmill locomotion before and after a striatal lesion in rats
    Perrot, O.
    Laroche, D.
    Pozzo, T.
    Marie, C.
    [J]. FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2008, 22 : 2 - 2
  • [4] The Effect of Gait Speed on Three-Dimensional Analysis of Hindlimb Kinematics during Treadmill Locomotion in Rats
    Costa, Luis M.
    Pereira, Jose E.
    Filipe, Vitor M.
    Couto, Pedro A.
    Magalhaes, Luis G.
    Bulas-Cruz, Jose
    Mauricio, Ana C.
    Geuna, Stefano
    Varejao, Artur S. P.
    [J]. REVIEWS IN THE NEUROSCIENCES, 2010, 21 (06) : 487 - 497
  • [5] Calibration of 3D ultrasound to an electromagnetic tracking system
    Lang, Andrew
    Parthasarathy, Vijay
    Jain, Ameet
    [J]. MEDICAL IMAGING 2011: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2011, 7968
  • [6] Bird terrestrial locomotion as revealed by 3D kinematics
    Abourachid, Anick
    Hackert, Remi
    Herbin, Marc
    Libourel, Paul A.
    Lambert, Francois
    Gioanni, Henri
    Provini, Pauline
    Blazevic, Pierre
    Hugel, Vincent
    [J]. ZOOLOGY, 2011, 114 (06) : 360 - 368
  • [7] Effect of local modulation of a real-time self-avatar on 3D gait kinematics during natural walking on a treadmill
    Cote, S. Saint-Pierre
    Charbonneau, P.
    Aissaoui, R.
    Nadeau, S.
    Duclos, C.
    Mezghani, N.
    Labbe, D. R.
    [J]. 2017 INTERNATIONAL CONFERENCE ON VIRTUAL REHABILITATION (ICVR), 2017,
  • [8] Pattern Comparison of 3D Lower Limb Kinematics During Overground and Treadmill Running
    Fellin, Rebecca E.
    Davis, Irene S.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S58 - S59
  • [9] Neuropathic gait shows only trends towards increased variability of sagittal plane kinematics during treadmill locomotion
    Dingwell, JB
    Ulbrecht, JS
    Boch, J
    Becker, MB
    O'Gorman, JT
    Cavanagh, PR
    [J]. GAIT & POSTURE, 1999, 10 (01) : 21 - 29
  • [10] Analysis of 3-D Kinematics Using H-Gait System during Walking on a Lower Body Positive Pressure Treadmill
    Kataoka, Yoshiaki
    Takeda, Ryo
    Tadano, Shigeru
    Ishida, Tomoya
    Saito, Yuki
    Osuka, Satoshi
    Samukawa, Mina
    Tohyama, Harukazu
    [J]. SENSORS, 2021, 21 (08)