Air flow distribution in and around a single-sided naturally ventilated room

被引:26
|
作者
Eftekhari, MM [1 ]
Marjanovic, LD [1 ]
Pinnock, DJ [1 ]
机构
[1] Univ Loughborough, Dept Civil & Bldg Engn, Loughborough LE11 3TU, Leics, England
关键词
natural ventilation; air flow distributions; wind flow measuring;
D O I
10.1016/S0360-1323(02)00016-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this research is to compare calculated and measured air flow distributions inside a test room which is naturally ventilated. The test room is situated in a relatively sheltered location and to visualise the resultant local wind pattern around the room for all prevailing wind directions wind tunnel trials were carried out. Both the wind tunnel and full-scale measurements show that the wind direction at the test cell was generally restricted to either a westerly or an easterly direction. To investigate air flow inside the room, the air pressures and velocities across the openings together with indoor air temperature and velocity at four locations and six different levels are measured. The experimental results demonstrate that for both winter and summer the air was entering the test room at bottom and leaving at the top louvre. Separate air flow and thermal modelling programs are used to predict the spatial distribution of the air flow and thermal comfort. The air flow distribution was predicted using a network air flow program. The predicted flow showed similar trends and the simulation results were in an agreement with the measured data. An explicit finite-difference thermal modelling simulation package was used to predict the thermal comfort indices. (C) 2003 Published by Elsevier Science Ltd.
引用
收藏
页码:389 / 397
页数:9
相关论文
共 50 条
  • [1] THE IMPACT OF VERANDA ON A SINGLE-SIDED NATURALLY VENTILATED BUILDING
    Mohamed, M. F.
    Prasad, D.
    King, S.
    [J]. ENVIRONMENT DESIGN GUIDE, 2010, (63) : 1 - 7
  • [2] Numerical simulation of air flow field in single-sided ventilated buildings
    Papakonstantinou, KA
    Kiranoudis, CT
    Markatos, NC
    [J]. ENERGY AND BUILDINGS, 2000, 33 (01) : 41 - 48
  • [3] Potential model for single-sided naturally ventilated buildings in China
    Yin Wei
    Zhang Guo-qiang
    Wang Xiao
    Liu Jing
    Xia San-xian
    [J]. SOLAR ENERGY, 2010, 84 (09) : 1595 - 1600
  • [4] LARGE EDDY SIMULATION OF SINGLE-SIDED VENTILATED ROOM WITH DIFFERENT LOCATION OF WINDOWS
    Idris, A.
    Huynh, B. P.
    [J]. ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 6B, 2015,
  • [5] An evolutionary approach to single-sided ventilated facade design
    Marzban, Samin
    Ding, Lan
    Fiorito, Francesco
    [J]. INTERNATIONAL HIGH-PERFORMANCE BUILT ENVIRONMENT CONFERENCE - A SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2016 SERIES (SBE16), IHBE 2016, 2017, 180 : 582 - 590
  • [6] The effect of wind on the convective heat transfer from the floor of single-sided naturally ventilated cubical enclosures
    Pokhrel, M. K.
    Anderson, T. N.
    Lie, T. T.
    [J]. ARCHITECTURAL SCIENCE REVIEW, 2020, 63 (05) : 417 - 424
  • [7] Effective depth of fresh air distribution in rooms with single-sided natural ventilation
    Gan, GH
    [J]. ENERGY AND BUILDINGS, 2000, 31 (01) : 65 - 73
  • [8] THE POTENTIAL OF NATURAL VENTILATION IN SINGLE-SIDED VENTILATED APARTMENT TO IMPROVE INDOOR THERMAL COMFORT AND AIR QUALITY
    Mohamed, M. F.
    Behnia, M.
    King, S.
    Prasad, D.
    [J]. PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, 2012, : 71 - 78
  • [9] SINGLE-SIDED VENTILATION .1. THE FLOW BETWEEN A CAVITY AND EXTERNAL AIR STREAM
    ELTELBANY, MMM
    MOKHTARZADEHDEHGHAN, MR
    REYNOLDS, AJ
    [J]. BUILDING AND ENVIRONMENT, 1985, 20 (01) : 15 - 24
  • [10] Prediction of airflow rate of single-sided room in cross wind
    Institute of Industrial Science, University of Tokyo, Japan
    [J]. Journal of Environmental Engineering, 2008, 73 (626) : 437 - 443