Magnetic resonance imaging perfusion is associated with disease severity and activity in multiple sclerosis

被引:7
|
作者
Sowa, Piotr [1 ,2 ]
Nygaard, Gro Owren [3 ]
Bjornerud, Atle [4 ,5 ]
Celius, Elisabeth Gulowsen [3 ,6 ]
Harbo, Hanne Flinstad [2 ,3 ]
Beyer, Mona Kristiansen [1 ,7 ]
机构
[1] Oslo Univ Hosp, Dept Radiol & Nucl Med, Kirkeveien 166,POB 4956 Nydalen, N-0424 Oslo, Norway
[2] Univ Oslo, Inst Clin Med, Fac Med, Oslo, Norway
[3] Oslo Univ Hosp, Dept Neurol, Oslo, Norway
[4] Oslo Univ Hosp, Intervent Ctr, Oslo, Norway
[5] Univ Oslo, Dept Phys, Oslo, Norway
[6] Univ Oslo, Inst Hlth & Soc, Fac Med, Oslo, Norway
[7] Oslo & Akershus Univ Coll Appl Sci, Dept Life Sci & Hlth, Oslo, Norway
关键词
Disease activity; Disease severity; Magnetic resonance imaging; Mean transit time; Multiple sclerosis; Perfusion-weighted imaging; MAGNIMS CONSENSUS GUIDELINES; NATURAL-HISTORY; FOLLOW-UP; DISABILITY; BRAIN; MRI; IMPAIRMENT; LESIONS; INJURY; DEMYELINATION;
D O I
10.1007/s00234-017-1849-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The utility of perfusion-weighted imaging in multiple sclerosis (MS) is not well investigated. The purpose of this study was to compare baseline normalized perfusion measures in subgroups of newly diagnosed MS patients. We wanted to test the hypothesis that this method can differentiate between groups defined according to disease severity and disease activity at 1 year follow-up. Baseline magnetic resonance imaging (MRI) including a dynamic susceptibility contrast perfusion sequence was performed on a 1.5-T scanner in 66 patients newly diagnosed with relapsing-remitting MS. From the baseline MRI, cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) maps were generated. Normalized (n) perfusion values were calculated by dividing each perfusion parameter obtained in white matter lesions by the same parameter obtained in normal-appearing white matter. Neurological examination was performed at baseline and at follow-up approximately 1 year later to establish the multiple sclerosis severity score (MSSS) and evidence of disease activity (EDA). Baseline normalized mean transit time (nMTT) was lower in patients with MSSS > 3.79 (p = 0.016), in patients with EDA (p = 0.041), and in patients with both MSSS > 3.79 and EDA (p = 0.032) at 1-year follow-up. Baseline normalized cerebral blood flow and normalized cerebral blood volume did not differ between these groups. Lower baseline nMTT was associated with higher disease severity and with presence of disease activity 1 year later in newly diagnosed MS patients. Further longitudinal studies are needed to confirm whether baseline-normalized perfusion measures can differentiate between disease severity and disease activity subgroups over time.
引用
收藏
页码:655 / 664
页数:10
相关论文
共 50 条
  • [1] Magnetic resonance imaging perfusion is associated with disease severity and activity in multiple sclerosis
    Piotr Sowa
    Gro Owren Nygaard
    Atle Bjørnerud
    Elisabeth Gulowsen Celius
    Hanne Flinstad Harbo
    Mona Kristiansen Beyer
    [J]. Neuroradiology, 2017, 59 : 655 - 664
  • [2] Markers of disease activity in multiple sclerosis: magnetic resonance imaging
    Paty, DW
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 1998, 5 : S15 - S16
  • [3] Magnetic resonance perfusion weighted imaging - a marker of inflammatory activity in multiple sclerosis?
    Sowa, P.
    Nygaard, G. O.
    Bjornerud, A.
    Damangir, S.
    Spulber, G.
    Celius, E. G.
    Due-Tonnessen, P.
    Harbo, H. F.
    Beyer, M. K.
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2014, 20 : 296 - 296
  • [4] Magnetic resonance perfusion imaging in patients with multiple sclerosis (MS)
    Papadaki, E
    Papanikolaou, N
    Karampekios, S
    Spilioti, M
    Maris, T
    Gourtsoyiannis, NC
    [J]. RADIOLOGY, 2002, 225 : 430 - 430
  • [5] Magnetic resonance perfusion-weighted imaging in multiple sclerosis
    Sabatini, M
    Placidi, G
    Sotgiu, A
    D'Emidio, E
    Splendiani, A
    Masciocchi, C
    Gallucci, M
    [J]. RIVISTA DI NEURORADIOLOGIA, 2003, 16 (06): : 1058 - 1060
  • [6] Reliability of Classifying Multiple Sclerosis Disease Activity Using Magnetic Resonance Imaging in a Multiple Sclerosis Clinic
    Altay, Ebru Erbayat
    Fisher, Elizabeth
    Jones, Stephen E.
    Hara-Cleaver, Claire
    Lee, Jar-Chi
    Rudick, Richard A.
    [J]. JAMA NEUROLOGY, 2013, 70 (03) : 338 - 344
  • [7] Magnetic Resonance Imaging in Multiple Sclerosis associated Seizures
    Yarraguntla, Kalyan
    Sriwastava, Shitiz
    Marawar, Rohit
    Basha, Maysaa
    Zutshi, Deepti
    Bernitsas, Evanthia
    [J]. NEUROLOGY, 2018, 90
  • [8] Correlating immunological and magnetic resonance imaging markers of disease activity in multiple sclerosis
    Giovannoni, G
    Kieseier, B
    Hartung, HP
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1998, 64 : S31 - S36
  • [9] Fatigue and magnetic resonance imaging activity in multiple sclerosis
    Mainero, C
    Faroni, J
    Gasperini, C
    Filippi, M
    Giugni, E
    Ciccarelli, O
    Rovaris, M
    Batianello, S
    Comi, G
    Pozzilli, C
    [J]. JOURNAL OF NEUROLOGY, 1999, 246 (06) : 454 - 458
  • [10] Fatigue and magnetic resonance imaging activity in multiple sclerosis
    C. Mainero
    J. Faroni
    C. Gasperini
    M. Filippi
    E. Giugni
    O. Ciccarelli
    M. Rovaris
    S. Bastianello
    G. Comi
    C. Pozzilli
    [J]. Journal of Neurology, 1999, 246 : 454 - 458