PURPOSE: To determine the accuracy of glaucoma detection by frequency-doubling perimetry. METHODS: Stereoview optic nerve photographs, visual field examination, intraocular pressure measurements, medical and ocular history, and a screening and full threshold frequency-doubling perimetry examination were performed in a prospective study of consecutive subjects, Inclusion criteria included age of 45 years or older, absence of ocular disease other than glaucoma, cataract, or mild drusen, and Snellen visual acuity of 20/60 or better. A total of 125 eyes in 102 glaucoma subjects and 95 eyes of 95 normal subjects were included. Each eye was classified as "normal," "glaucoma," Or "uncertain" by each of three ophthalmologists on the basis of all available clinical information with the exception of frequency-doubling perimetry results. Those in the glaucoma group were subclassified as having early (n = 51), moderate (n = 42), or severe (n = 32) glaucoma on the basis of automated Humphrey visual field criteria. In the glaucoma group, two eyes from a subject were allowed to be included (23 of 102 subjects) if they differed in level of damage because they were never analyzed within the same statistical analysis. RESULTS: Several diagnostic algorithms were evaluated. Algorithms based on the most depressed single point, pair of adjacent points, and cluster of three points performed nearly identically. For the screening test, if any abnormality was identified, specificity was 95%, whereas sensitivity was 39%, 86%, and 100% for early, moderate, and severe glaucoma, respectively. For the full threshold test, with at least one point depressed to the P < 0.5% level, specificity measured 91%, whereas sensitivity was 35%, 88%, and 100% for early, moderate, and severe glaucoma, respectively, The two global indices, mean deviation and pattern standard deviation, were also evaluated and were generally less accurate. CONCLUSION: Frequency-doubling perimetry, which is rapid and easily administered, is effective at detecting moderate and severe disease and appears well suited for glaucoma screening. (C) 2000 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:740 / 745
页数:6
相关论文
共 50 条
  • [1] Frequency-doubling perimetry: Comparison with standard automated perimetry to detect glaucoma
    Leeprechanon, Narakorn
    Giangiacomo, Annette
    Fontana, Hector
    Hoffman, Douglas
    Caprioli, Joseph
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (02) : 263 - 271
  • [2] Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma
    Fogagnolo, Paolo
    Rossetti, Luca
    Ranno, Stefano
    Ferreras, Antonio
    Orzalesi, Nicola
    [J]. GLAUCOMA: AN OPEN WINDOW TO NEURODEGENERATION AND NEUROPROTECTION, 2008, 173 : 101 - 124
  • [3] Impact of diabetes on glaucoma screening using frequency-doubling perimetry
    Realini, T
    Lai, MQ
    Barber, L
    [J]. OPHTHALMOLOGY, 2004, 111 (11) : 2133 - 2136
  • [4] Insights for mfVEPs from perimetry using large spatial frequency-doubling and near frequency-doubling stimuli in glaucoma
    Abdullah, Siti Nurliyana
    Sanderson, Gordon F.
    Husni, Mohd Aziz
    Maddess, Ted
    [J]. DOCUMENTA OPHTHALMOLOGICA, 2020, 141 (01) : 45 - 55
  • [5] Comparison of Standard Automated Perimetry, Frequency-Doubling Technology Perimetry, and Short-Wavelength Automated Perimetry for Detection of Glaucoma
    Liu, Shu
    Lam, Shi
    Weinreb, Robert N.
    Ye, Cong
    Cheung, Carol Y.
    Lai, Gilda
    Lam, Dennis Shun-Chiu
    Leung, Christopher Kai-Shun
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7325 - 7331
  • [6] Insights for mfVEPs from perimetry using large spatial frequency-doubling and near frequency-doubling stimuli in glaucoma
    Siti Nurliyana Abdullah
    Gordon F. Sanderson
    Mohd Aziz Husni
    Ted Maddess
    [J]. Documenta Ophthalmologica, 2020, 141 : 45 - 55
  • [7] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Folkert K. Horn
    Nina Wakili
    Anselm M. Jünemann
    Matthias Korth
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 658 - 665
  • [8] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Horn, FK
    Wakili, N
    Jünemann, AM
    Korth, M
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (08) : 658 - 665
  • [9] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Seong Ah Kim
    Chan Kee Park
    Hae-Young Lopilly Park
    [J]. Scientific Reports, 12
  • [10] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Kim, Seong Ah
    Park, Chan Kee
    Park, Hae-Young Lopilly
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)