Effect of environmental thermal disturbance on effective thermal conductivity of ground source heat pump system

被引:11
|
作者
Zhou, Kun [1 ]
Mao, Jinfeng [1 ]
Li, Yong [1 ]
Zhang, Hua [1 ]
Li, Chaofeng [2 ]
Wang, Lijun [3 ]
机构
[1] Army Engn Univ PLA, Nanjing 210007, Peoples R China
[2] Acad Mil Sci PLA China, Beijing 100091, Peoples R China
[3] 32085 PLA, Beijing 100082, Peoples R China
基金
中国国家自然科学基金;
关键词
Ground source heat pump; Thermal response test; Ground thermal conductivity; Numerical simulation; Environmental thermal disturbance; RESPONSE TEST; ENERGY PILES; PERFORMANCE; TEMPERATURE; SOIL; PIPE; EXCHANGER; DESIGN; MODEL; SENSITIVITY;
D O I
10.1016/j.enconman.2021.114149
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ground thermal conductivity, As, is one of the important design factors for the ground source heat pump system. This study aimed to investigate the effect of environmental thermal disturbance on the As estimation during the thermal response test (TRT), which is interpreted by the infinite line source model. For this purpose, a detailed numerical model considering the heat exchange between the circulating fluid inside the above-ground pipe of TRT rig and the outdoor environment in two representative seasons was developed. The numerical model was compared with the model with the adiabatic boundary assigned to the outer surface of above-ground pipe to evaluate the fluctuations of As on account of the atmospheric disturbance. The parametric and sensitivity analyses were carried out to quantify the impacts of TRT seasons and above-ground pipe parameters including the surface absorptivity, thickness, and thermal conductivity of insulation material, and the length of the above-ground pipe on the As and corresponding design borehole length. An approach of prolonging the TRT duration was proposed to impair the disturbance when the pipe is not insulated. Results show that As fluctuates strongly and is largely misestimated considering the atmospheric disturbance, especially when TRT duration is limited. The As varies widely as the length of above-ground pipe, insulation surface absorptivity, and insulation thermal conductivity increase, insulation thickness decreases, and TRT starts in summer. The pipe length is the most significant factor to the uncertainty of As. The test time is recommended to last at least 3 days in summer and 3.6 days in winter when the pipe is not wrapped by a layer of insulation material. This study quantitatively assesses the impacts of environmental thermal disturbance during the TRT and gives guidance to carry out TRT properly.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Hybrid Solar Thermal and Ground Source Heat Pump System
    Rad, Farzin M.
    Fung, Alan S.
    Leong, Wey H.
    [J]. ASHRAE TRANSACTIONS 2012, VOL 118, PT 2, 2012, 118 : 253 - 260
  • [2] Enhanced Ground Source Heat Pump System With Thermal Storage System
    Taira, Hirotoshi
    Sato, Takashi
    Kakizaki, Takao
    Oguma, Masahito
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2019, 141 (06):
  • [3] ENHANCED GROUND SOURCE HEAT PUMP SYSTEM WITH THERMAL STORAGE SYSTEM
    Taira, Hirotoshi
    Sato, Takashi
    Kakizaki, Takao
    Oguma, Masahito
    [J]. PROCEEDINGS OF THE ASME 12TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2018, 2018,
  • [4] The Experimental Thermal Performance Analysis of the Ground Source Heat Pump System Dependent on Environmental Conditions
    Karabacak, R.
    Acar, S. Gueven
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2010, 32 (12) : 1142 - 1158
  • [5] A Study on the Calculation Model of Rock Soil Thermal Conductivity in the Design of the Ground Source Heat Pump System
    Jin Hongwen
    Fang Qingshen
    [J]. ENGINEERING SOLUTIONS FOR MANUFACTURING PROCESSES IV, PTS 1 AND 2, 2014, 889-890 : 1347 - +
  • [6] Simulations of a photovoltaic-thermal ground source heat pump system
    Varney, Kevin E.
    Vahdati, Maria M.
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING SUSTAINABILITY, 2015, 168 (01) : 28 - 37
  • [7] Optimization of thermal performance of a building with ground source heat pump system
    Zogou, Olympia
    Stamatelos, Anastassios
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (11) : 2853 - 2863
  • [8] Testing and Analysis of Thermal Performance of Ground Source Heat Pump System
    Qu Shilin
    Xu, Ge
    Liu Yimin
    Yu Qian
    [J]. 2011 2ND INTERNATIONAL CONFERENCE ON CHALLENGES IN ENVIRONMENTAL SCIENCE AND COMPUTER ENGINEERING (CESCE 2011), VOL 11, PT B, 2011, 11 : 566 - 572
  • [9] Study on Heat Transfer of Soil Thermal Recovery of Ground Source Heat Pump System
    Zhou, Ping
    Chen, Chao
    Wu, Jinshun
    Hu, Guixia
    Guo, Yang
    Li, Kang
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 449 - 460
  • [10] Effect of degree of saturation on thermal conductivity of CLSM used for a horizontal ground coupled heat pump system
    Do, T. M.
    Kim, Y. S.
    Lee, C. H.
    Dang, M. Q.