Influence of intraoral conditions on the accuracy of full-arch scans by Cerec Primescan AC: an in vitro and in vivo comparison

被引:0
|
作者
Keul, Christine [1 ]
Guth, Jan-Frederik [2 ]
机构
[1] Ludwig Maximilians Univ LMU, Univ Hosp, Dept Prosthet Dent, Munich, Germany
[2] Goethe Univ, Ctr Dent & Oral Med Carolinum, Dept Prosthet Dent, Frankfurt, Germany
关键词
digital impression; full-arch accuracy; in vitro digitalization; in vivo digitalization; SCANNING SYSTEMS; IMPLANT IMPRESSION; DIGITAL METHODS; SCANNERS; PRECISION; STRATEGIES; TRUENESS; IMPACT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: To determine the effect of intraoral conditions on the accuracy of digital full-arch scans. Materials and methods: A reference bar was used for the in vivo and in vitro parts of the present study. For the in vitro part (PAT-vitro), the bar was fixed to connect the maxillary second molars on the patient's resin model. The same reference bar was fixed in a similar position intraorally for the in vivo testing (PAT-vivo). Model and patient were digitized using an intraoral scanner (Cerec Primescan AC, N = 40, n [PAT-vitro] = 20, n [PAT-vivo] = 20). Datasets were exported and metrically analyzed (Geomagic Control 2015) to determine the 3D linear and angular distortions in all three coordinate axes of the datasets with reference to the bar. Normality of the data distribution was tested using the Kolmogorov-Smirnov and Shapiro-Wilk tests. Homogeneity of the variances was tested using the Levene test. Statistically significant differences for all measured parameters in view of trueness were determined using the two-sample t test, and in view of precision using the two-sample Kolmogorov-Smirnov test. Results: The PAT-vivo group showed significantly higher trueness for most of the measured linear and angular distortion parameters than the PAT-vitro group. Regarding precision, the PAT-vitro group showed significantly better values for most of the measured linear and angular distortion parameters than the PAT-vivo group. Conclusions: Within the limitations of the present study, Cerec Primescan AC leads to comparable accuracy parameters when applied in vivo and in vitro. The reproducibility (precision) was higher when scans were performed in vitro. Due to the high trueness, the system seems to be a valid tool to obtain digital full-arch datasets in vivo with comparable accuracy to in vitro tests.
引用
收藏
页码:17 / 25
页数:9
相关论文
共 50 条
  • [1] Accuracy of full-arch scans using intraoral scanners
    Patzelt, Sebastian B. M.
    Emmanouilidi, Archontia
    Stampf, Susanne
    Strub, Joerg R.
    Att, Wael
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1687 - 1694
  • [2] Accuracy of full-arch scans using intraoral scanners
    Sebastian B. M. Patzelt
    Archontia Emmanouilidi
    Susanne Stampf
    Joerg R. Strub
    Wael Att
    [J]. Clinical Oral Investigations, 2014, 18 : 1687 - 1694
  • [3] Accuracy of full-arch digital impressions: an in vitro and in vivo comparison
    Keul, Christine
    Gueth, Jan-Frederik
    [J]. CLINICAL ORAL INVESTIGATIONS, 2020, 24 (02) : 735 - 745
  • [4] Accuracy of full-arch digital impressions: an in vitro and in vivo comparison
    Christine Keul
    Jan-Frederik Güth
    [J]. Clinical Oral Investigations, 2020, 24 : 735 - 745
  • [5] In vivo full-arch accuracy of intraoral scanners: a narrative review
    Jennes, Marie-Elise
    Soetebeer, Maren
    Beuer, Florian
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2022, 25 (01) : 9 - 16
  • [6] Accuracy of full-arch scans using intraoral and extraoral scanners: an in vitro study using a new method of evaluation
    Muallah, J.
    Wesemann, C.
    Nowak, R.
    Robben, J.
    Mah, J.
    Pospiech, P.
    Bumann, A.
    [J]. INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (02) : 151 - 164
  • [7] Full-arch accuracy of five intraoral scanners: In vivo analysis of trueness and precision
    Kwon, Miran
    Cho, Youngmok
    Kim, Dong-Wook
    Kim, MyungSu
    Kim, Yoon-Ji
    Chang, Minho
    [J]. KOREAN JOURNAL OF ORTHODONTICS, 2021, 51 (02) : 95 - 104
  • [8] Comparison of the accuracy between full-arch digital scans and scannable impression materials: an in vitro study
    Grande, Francesco
    Celeghin, Giordano
    Gallinaro, Federica
    Mobilio, Nicola
    Catapano, Santo
    [J]. MINERVA DENTAL AND ORAL SCIENCE, 2023, 72 (04) : 168 - 175
  • [9] In vitro and in vivo accuracy of full-arch digital implant impressions
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Akulauskas, Mykolas
    Fehmer, Vincent
    Sailer, Irena
    Jegelevicius, Darius
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (12) : 1444 - 1454
  • [10] Effect of auxiliary geometric devices on the accuracy of intraoral scans in full-arch implant-supported rehabilitations: An in vitro study
    Canullo, Luigi
    Pesce, Paolo
    Caponio, Vito Carlo Alberto
    Iacono, Roberta
    Raffone, Carlo
    Luciani, Francesco Saverio
    Menini, Maria
    [J]. JOURNAL OF DENTISTRY, 2024, 145