Minimum local analgesic concentration of extradural bupivacaine increases with progression of labour

被引:85
|
作者
Capogna, G
Celleno, D
Lyons, G
Columb, M
Fusco, P
机构
[1] Fatebenefratelli Gen Hosp, Dept Anaesthesiol, I-00186 Rome, Italy
[2] Fatebenefratelli Gen Hosp, Dept Obstet & Gynaecol, I-00186 Rome, Italy
[3] St James Univ Hosp, Leeds LS9 7TF, W Yorkshire, England
[4] Withington Hosp, Intens Care Unit, Manchester M20 2LR, Lancs, England
关键词
pregnancy; analgesia; obstetric; analgesic techniques; extradural; anaesthetics local; bupivacaine;
D O I
10.1093/bja/80.1.11
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have used the technique of double-blind sequential allocation to quantify the minimum local analgesic concentration (MLAC) of extradural bupivacaine for women in early (median cervical dilatation 2 cm) and late (median cervical dilatation 5 cm) labour. The first bolus was 20 mi of the bupivacaine test solution. The concentration was determined by the response of the previous woman to a higher or lower concentration of bupivacaine according to up and down sequential allocation. Efficacy was assessed using a 100-mm visual analogue pain score (VAPS). The test solution had to achieve a VAPS of 10 mm or less to be judged effective. In early labour, the MLAC of bupivacaine was 0.048% w/v (95% confidence intervals (CI) 0.037-0.058% w/v), and 0.140% w/v (95% CI 0.132-0.150% w/v) in the late group. The MLAC of bupivacaine in late labour was greater by a factor of 2.9 (95% CI 2.7-3.2) compared with the MLAC in early labour (P < 0.0001, 95% CI difference 0.08-0.11). We conclude that advancing labour requires an increased concentration of extradural bupivacaine for pain relief.
引用
收藏
页码:11 / 13
页数:3
相关论文
共 50 条
  • [1] Effect of epidural epinephrine on the minimum local analgesic concentration of epidural bupivacaine in labor
    Polley, LS
    Columb, MO
    Naughton, NN
    Wagner, DS
    van de Ven, CJM
    [J]. ANESTHESIOLOGY, 2002, 96 (05) : 1123 - 1128
  • [2] Effect of epidural sufentanil on the minimum local analgesic concentration (MLAC) of epidural bupivacaine in labor
    Polley, LS
    Columb, MO
    Wagner, DS
    Benedict, PE
    Balachandran, KA
    Kaczynski, DA
    [J]. ANESTHESIA AND ANALGESIA, 1997, 84 : S402 - S402
  • [3] Does intrathecal analgesia reduce the subsequent minimum local analgesic concentration of epidural bupivacaine?
    Carvalho, B.
    Landau, R.
    [J]. ANAESTHESIA, 2012, 67 (09) : 1054 - 1055
  • [4] Optimal concentration for an initial bolus of bupivacaine for extradural analgesia during labour
    Siegemund, M
    Harms, C
    Hampl, KF
    Marsch, SC
    Schneider, MC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 : A330 - A330
  • [5] Effect of sufentanil on minimum local analgesic concentrations of epidural bupivacaine, ropivacaine and levobupivacaine in nullipara in early labour
    Buyse, I.
    Stockman, W.
    Columb, M.
    Vandermeersch, E.
    de Velde, M. Van
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2007, 16 (01) : 22 - 28
  • [6] Minimum local analgesic concentration of local anaesthetics
    Columb, Malachy
    Gall, Iain
    [J]. BJA EDUCATION, 2010, 10 (04) : 114 - 116
  • [7] Effect of intravenous versus epidural fentanyl on the minimum local analgesic concentration of epidural bupivacaine in labor
    Polley, LS
    Columb, MO
    Naughton, NN
    Wagner, DS
    Dorantes, DM
    van de Ven, CJM
    [J]. ANESTHESIOLOGY, 2000, 93 (01) : 122 - 128
  • [8] Does intrathecal analgesia reduce the subsequent minimum local analgesic concentration of epidural bupivacaine? Reply
    Armstrong, S.
    Fernando, R.
    Columb, M.
    [J]. ANAESTHESIA, 2012, 67 (09) : 1055 - 1056
  • [9] The effects of adding fentanyl and epinephrine on the minimum local analgesic concentration of bupivacaine for labor analgesia.
    Shue, SS
    Tirado, C
    Grinberg, A
    Kraemer, JJ
    Hess, PE
    [J]. ANESTHESIOLOGY, 2006, 104 (04) : B29 - B29
  • [10] Combined spinal epidural vs epidural labour analgesia: does initial intrathecal analgesia reduce the subsequent minimum local analgesic concentration of epidural bupivacaine?
    Patel, N. P.
    Armstrong, S. L.
    Fernando, R.
    Columb, M. O.
    Bray, J. K.
    Sodhi, V.
    Lyons, G. R.
    [J]. ANAESTHESIA, 2012, 67 (06) : 584 - 593