摘要
In recent years, the popularity of intramedullary humeral nailing is on the rise in spite of its handicaps. There are many problems in intramedullary humeral. stabilization because of the anatomic structure of the bone. We performed various methods and measurements to determine shape, length and diameter and curvature of the medullary canal of the humerus in 57 human dry cadaver bones. Anterior angulation with an average of 21 cm apart from greater tubercle was found at 1/3 distal part. Mean degree of angulation was 9degrees (max: 15, minutes: 5, S.D.: 2.84). Humerus bones with septal aperture (supratrochlear foramen) at the fossa coronoidea were observed to have very narrow medullary canal. The best point for nail insertion was found to be an area on the line from greater tubercle anteromedially to caput humeri. This study revealed that carefully evaluated structure of humeral medullary canal and various congenital constructions such as septal aperture, and correct selection of a nail with proper length and diameter are essential for successful nailing.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 50 条
  • [1] SEQUELA TO INTRAMEDULLARY FIXATION OF HUMERUS IN AN OSPREY
    CHAFFEE, VW
    VETERINARY MEDICINE & SMALL ANIMAL CLINICIAN, 1973, 68 (08): : 892 - 894
  • [2] Comparative Study of the Fractured Humerus Fixation by Intramedullary Nailing and Compression Plate
    Keddar, Ibrahim
    Aour, Benaoumeur
    Zahaf, Samir
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2022, 22 (05) : 1905 - 1923
  • [3] INTRAMEDULLARY FIXATION OF FRACTURES OF THE HUMERUS BY THE LONGITUDINAL PIN
    RUSH, LV
    RUSH, HL
    SURGERY, 1950, 27 (02) : 268 - 275
  • [4] INTRAMEDULLARY FIXATION OF A FRACTURED HUMERUS IN A WILD OWL
    SCOTT, CD
    CANADIAN VETERINARY JOURNAL, 1968, 9 (04): : 98 - &
  • [5] Fixation of a Proximal Humerus Fracture With an Intramedullary Nail
    Sobel, Andrew D.
    Shah, Kalpit N.
    Paxton, E. Scott
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 : S47 - S49
  • [6] Comparative Study of the Fractured Humerus Fixation by Intramedullary Nailing and Compression Plate
    Ibrahim Keddar
    Benaoumeur Aour
    Samir Zahaf
    Journal of Failure Analysis and Prevention, 2022, 22 : 1905 - 1923
  • [7] KUNTSCHER INTRAMEDULLARY REAMING AND NAIL FIXATION FOR NONUNION OF HUMERUS
    CHRISTENSEN, NO
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1976, (116) : 222 - 226
  • [8] RUSH PIN INTRAMEDULLARY FIXATION FOR FRACTURES OF PROXIMAL HUMERUS
    WESELEY, MS
    BARENFELD, PA
    EISENSTEIN, AL
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1977, 17 (01): : 29 - 37
  • [9] Intramedullary plate fixation of a distal humerus fracture: A case report
    Russell, GV
    Pearsall, AW
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) : 353 - 356
  • [10] Midterm Treatment Outcomes of Proximal Humerus Fractures by Intramedullary Fixation
    Egiazaryan, K. A.
    Ratyev, A. P.
    Gordienko, D., I
    Grigoriev, A., V
    Ovcharenko, N., V
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2018, 24 (04): : 81 - 88