Biaxial Strain Control Fatigue Testing Strategies for Composite Materials

被引:5
|
作者
Moncy, A. [1 ]
Waldbjorn, J. P. [1 ]
Berggreen, C. [1 ]
机构
[1] Tech Univ Denmark, Dept Mech Engn, Nils Koppels Alle,Bldg 404, DK-2800 Lyngby, Denmark
关键词
Biaxial strain control; Real time digital image point tracking; Composite materials; Cruciform specimen; Fatigue testing; FAILURE; EVOLUTION; PRESSURE; SPECIMEN; CRACKING; TENSION; DESIGN; TUBES;
D O I
10.1007/s11340-021-00725-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background Efficient biaxial strain control to study fatigue damage growth in composite materials at the coupon scale level under realistic multi-axial stress states observed in structures is needed. Objective Two biaxial cyclic strain control algorithms, referred to here as the active and the passive control method, are presented as a fatigue testing strategy for composite materials. Method The strain is measured at a sampling frequency of 116 Hz through a real-time digital image point tracking system. The active control method utilizes a cascade control algorithm to accommodate the low sampling rate of the digital image point tracking system relative to the servo-hydraulic PID controller. The passive control method is a conditional control algorithm where the force command is adjusted when the measured peak-valley strain violates the predefined strain tolerance. The performance of these control techniques are initially evaluated on uniaxial coupon specimens to investigate the effect of testing frequency, strain magnitude, accuracy of the stiffness parameter and the tolerance band. Subsequently, the two control methods are verified on cruciform specimens under different biaxial strain states. Results Under biaxial loading, the peak feedback strains had a maximum error of 6.4% and 9.0% for the active and the passive control method respectively, depending on the required biaxial strain state. Conclusions The active control method was found to offer a better accuracy relative to the passive control method. However, it suffered from a lower fidelity as the test stopped whenever the real-time digital image point tracking system lost track of the point markers.
引用
收藏
页码:1193 / 1208
页数:16
相关论文
共 50 条
  • [1] Biaxial Strain Control Fatigue Testing Strategies for Composite Materials
    A. Moncy
    J. P. Waldbjørn
    C. Berggreen
    Experimental Mechanics, 2021, 61 : 1193 - 1208
  • [2] Strain measurements on specimens subjected to biaxial ultrasonic fatigue testing
    Vieira, M.
    Reis, L.
    Freitas, M.
    Ribeiro, A.
    THEORETICAL AND APPLIED FRACTURE MECHANICS, 2016, 85 : 2 - 8
  • [3] Design of a cylindrical specimen for biaxial testing of composite materials
    Smith, LV
    Swanson, SR
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 1997, 16 (06) : 550 - 565
  • [4] Biaxial thermal fatigue testing with non-uniform strain distributions
    Tretyachenko, GN
    Karpinos, BS
    Barilo, VG
    Solovyova, NG
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 1996, 19 (10) : 1239 - 1253
  • [5] Biaxial thermal fatigue testing with non-uniform strain distributions
    Tretyachenko, G.N.
    Karpinos, B.S.
    Barilo, V.G.
    Solovyova, N.G.
    Fatigue and Fracture of Engineering Materials and Structures, 1996, 19 (10): : 1239 - 1253
  • [6] Biaxial materials testing
    Biaxiale werkstoffprüfungu
    2001, Carl Hanser Verlag (43):
  • [7] FATIGUE TESTING OF PULTRUDED COMPOSITE-MATERIALS
    DONTI, RP
    VAUGHAN, JG
    EXPERIMENTAL TECHNIQUES, 1994, 18 (03) : 27 - 29
  • [8] Biaxial materials testing
    Biaxiale Werkstoffprüfung: Eine neue Methode zur Beschreibung des Werkstoffverhaltens von Stahlfeinblechgüten
    2001, Walter de Gruyter GmbH (43):
  • [9] BIAXIAL TESTING OF COMPOSITE TUBES
    TOOMBES, GR
    SWANSON, SR
    CAIRNS, DS
    EXPERIMENTAL MECHANICS, 1985, 25 (02) : 186 - 192
  • [10] Development of a Delamination Fatigue Testing Machine for Composite Materials
    Pereira, Antonio B.
    Fernandes, Fabio A. O.
    de Morais, Alfredo B.
    Carvalhoso, Pedro
    MACHINES, 2019, 7 (02)