Coregistration of Preoperative Computed Tomography and Intraoperative Three-Dimensional Rotational X-Ray Images for Cochlear Implant Surgical Evaluation

被引:0
|
作者
Pearlman, Paul C. [1 ]
van Deurzen, Martinus H. W. [2 ,3 ]
Pluim, Josien P. W. [1 ]
Grolman, Wilko [2 ,3 ]
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Otorhinolaryngol & Head & Neck Surg, NL-3508 GA Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Brain Ctr Rudolf Magnus, NL-3508 GA Utrecht, Netherlands
关键词
3DRX; Cochlear implant; Deafness; Hearing loss; Intraoperative imaging; Surgery; ELECTRODE ARRAY; SPEECH-PERCEPTION; SURGERY; INSERTION; NAVIGATION; POSITION; ADULTS; COMPLICATIONS; PRESERVATION; STIMULATION;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: A registration procedure of intraoperative three-dimensional rotational x-ray (3DRX) imaging and preoperative computed tomography (CT) imaging so that intraoperative CT quality imaging is available during cochlear implant surgery, providing detailed information concerning electrode position in the cochlea and its relation to surrounding bony structures. Study Design: Retrospective case series Setting: Tertiary referral center Data: The imaging of five patients who had undergone cochlear implant surgery is used to develop a semiautomatic registration procedure to integrate intraoperative 3DRX and preoperative CT. The method is implemented in advanced medical imaging software to compute the transformations. The electrode is segmented from the registered 3DRX images using a semiautomated approach. The segmented electrode is superimposed onto the CT data. The methods are quantitatively validated based on expert-labeled anatomical landmarks. These landmarks are identified in the CT and 3DRX images by an expert. Main Outcome Measure: Mean error of the registration procedure for five anatomical landmarks in millimeters. Results: Quantitative analysis showed a mean error of between 0.5 and 1 mm for all anatomical landmarks, suggesting that the results are trustworthy. Conclusion: We developed a reliable procedure for the registration of intraoperative 3DRX imaging and preoperative CT imaging for cochlear implant surgery. This registration procedure provides the ENT surgeon intraoperative high-quality CT imaging during cochlear implant surgery.
引用
收藏
页码:1759 / 1764
页数:6
相关论文
共 50 条
  • [1] Ultrafast three-dimensional x-ray computed tomography
    Bieberle, Martina
    Barthel, Frank
    Menz, Hans-Juergen
    Mayer, Hans-Georg
    Hampel, Uwe
    APPLIED PHYSICS LETTERS, 2011, 98 (03)
  • [2] ALGORITHM OF RECONSTRUCTION OF THREE-DIMENSIONAL IMAGES IN X-RAY COMPUTED TOMOGRAPHY WITH A CONE BEAM
    Simonov, E.
    Prokhorov, A., V
    BULLETIN OF THE SOUTH URAL STATE UNIVERSITY SERIES-MATHEMATICAL MODELLING PROGRAMMING & COMPUTER SOFTWARE, 2021, 14 (01): : 104 - 117
  • [3] Three-dimensional shape estimation of wires from three-dimensional X-ray computed tomography images of electrical cables
    Ueda, Shiori
    Sato, Kanon
    Saito, Hideo
    Hoshina, Yutaka
    JOURNAL OF ELECTRONIC IMAGING, 2024, 33 (03)
  • [4] An algorithm for reconstruction of three-dimensional images in computed X-ray tomography with a cone irradiation beam
    Simonov, E. N.
    Vinogradov, K. M.
    BIOMEDICAL ENGINEERING, 2023, 57 (04) : 271 - 275
  • [5] Three-dimensional numerical schemes for the segmentation of the psoas muscle in X-ray computed tomography images
    Paolucci, Giulio
    Cama, Isabella
    Campi, Cristina
    Piana, Michele
    BMC MEDICAL IMAGING, 2024, 24 (01):
  • [6] Fast Three-Dimensional Focused X-ray Luminescence Computed Tomography
    Lun, Michael C.
    Fang, Yile
    Li, Changqing
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [7] Three-dimensional computed tomography angiography of the internal carotid artery for preoperative evaluation of sinonasal lesions and Intraoperative surgical navigation
    Leong, JL
    Batra, PS
    Citardi, MJ
    LARYNGOSCOPE, 2005, 115 (09): : 1618 - 1623
  • [8] Three-dimensional iterative multislice reconstruction for ptychographic X-ray computed tomography
    Shimomura, Kei
    Hirose, Makoto
    Higashino, Takaya
    Takahashi, Yukio
    OPTICS EXPRESS, 2018, 26 (24): : 31199 - 31208
  • [9] X-Ray Computed Tomography of Holographically Fabricated Three-Dimensional Photonic Crystals
    Chen, Ying-Chieh
    Geddes, Joseph B., III
    Yin, Leilei
    Wiltzius, Pierre
    Braun, Paul V.
    ADVANCED MATERIALS, 2012, 24 (21) : 2863 - 2868
  • [10] Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation
    Saito, T
    Kudo, H
    Takeda, T
    Itai, Y
    Tokumori, K
    Toyofuku, F
    Hyodo, K
    Ando, M
    Nishimura, K
    Uyama, C
    OPTICAL ENGINEERING, 1998, 37 (08) : 2258 - 2268