Determination of Hydrogen Peroxide on Modified Glassy Carbon Electrode by Polytetrakis(2-aminophenyl)porphyrin Nanowire

被引:6
|
作者
Jeong, Haesang [3 ]
Kim, Songmi [1 ,2 ]
Seol, Heejin [1 ,2 ]
You, Jung-Min [1 ,2 ]
Jeong, Eun Seon [1 ,2 ]
Kim, Seul Ki [1 ,2 ]
Seo, Kyung-Sik [3 ]
Jeon, Seungwon [1 ,2 ]
机构
[1] Chonnam Natl Univ, Dept Chem, Kwangju 500757, South Korea
[2] Chonnam Natl Univ, Inst Basic Sci, Kwangju 500757, South Korea
[3] Momed Co, Nano Bio Applicat Lab, Kwangju 500480, South Korea
来源
BULLETIN OF THE KOREAN CHEMICAL SOCIETY | 2009年 / 30卷 / 12期
关键词
Porphyrin nanowire; Single-walled carbon nanotubes; Hydrogen peroxide; Electrochemical sensor; Amperometry; POLY(NEUTRAL RED); ELECTROCATALYTIC OXIDATION; ASCORBIC-ACID; NANOTUBES; DOPAMINE; ARRAYS; FILM; FABRICATION; ELECTROPOLYMERIZATION; NOREPINEPHRINE;
D O I
10.5012/bkcs.2009.30.12.2979
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Nanowires of polytetrakis(o-aminophenyl)porphyrin (PTAPPNW) were fabricated by electrochemical polymerization with the cyclic voltammetric method in anodic aluminum oxide (AAO) membranes. The glassy carbon electrode (GCE) modified by PTAPPNW, single-walled carbon nanotubes (SWNT) and Nafion as a binder was investigated with voltammetric methods in a phosphate buffer saline (PBS) solution at pH 7.4. The PTAPPNW + SWNT + Nafion/GCE exhibited strongly enhanced voltammetric and amperometric sensitivity towards hydrogen peroxide (H2O2), which shortened the response time and enhanced the sensitivity far H2O2 determination at an applied potential of 0.0 V by amperometric method. The PTAPPNW + SWNT + Nafion/GCE can be used to monitor H2O2 at very low concentrations in biological pH as an efficient electrochemical H2O2 sensor.
引用
收藏
页码:2979 / 2983
页数:5
相关论文
共 50 条
  • [1] Determination of Serotonin on a Glassy Carbon Electrode Modified by Electropolymerization of Meso-Tetrakis(2-aminophenyl)porphyrin and Single Walled Carbon Nanotubes
    Kim, Seul Ki
    Ahmed, Mohammad Shamsuddin
    Jeong, Haesang
    You, Jung-Min
    Jeon, Seungwon
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2011, 11 (03) : 2407 - 2412
  • [2] Preparation and characterization of diethylene glycol bis(2-aminophenyl) ether-modified glassy carbon electrode
    Isbir, Aybuke A.
    Solak, Ali Osman
    Ustundag, Zafer
    Bilge, Selen
    Kilic, Zeynel
    ANALYTICA CHIMICA ACTA, 2006, 573 : 26 - 33
  • [3] Electrochemical determination of hydrogen peroxide at a glassy carbon electrode modified with palladium nanoparticles
    Kitte, Shimeles Addisu
    Assresahegn, Birhanu Desalegn
    Soreta, Tesfaye Refera
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (05) : 701 - 711
  • [4] A modified glassy carbon electrode for hydrogen peroxide sensing
    Zheng, Cai-yun
    Chen, Shui-hong
    Shang, Yong-jia
    Li, Mao-guo
    ANNALI DI CHIMICA, 2007, 97 (11-12) : 1227 - 1235
  • [5] Reductive determination of hydrogen peroxide with MWCNTs-Pd nanoparticles on a modified glassy carbon electrode
    You, Jung-Min
    Jeong, Yu Na
    Ahmed, Mohammad Shamsuddin
    Kim, Seul Ki
    Choi, Hyun Chul
    Jeon, Seungwon
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2287 - 2291
  • [6] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [7] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    Microchimica Acta, 2016, 183 : 911 - 916
  • [8] Zn(II)-selective membrane electrode based on tetra(2-aminophenyl) porphyrin
    Fakhari, AR
    Shamsipur, M
    Ghanbari, K
    ANALYTICA CHIMICA ACTA, 2002, 460 (02) : 177 - 183
  • [9] TiO2/MWCNT/Nafion-Modified Glassy Carbon Electrode as a Sensitive Voltammetric Sensor for the Determination of Hydrogen Peroxide
    de Oliveira, Rafael Henrique
    Goncalves, Daniel A.
    dos Reis, Diogo Duarte
    SENSORS, 2023, 23 (18)
  • [10] Immobilization of enzymes on the nano-Au film modified glassy carbon electrode for the determination of hydrogen peroxide and glucose
    Lei, CX
    Wang, H
    Shen, GL
    Yu, RQ
    ELECTROANALYSIS, 2004, 16 (09) : 736 - 740