Lumped parameter heart model with valve dynamics

被引:7
|
作者
Simakov, Sergey S. [1 ,2 ]
机构
[1] Moscow Inst Phys & Technol, Dolgoprudnyi 141701, Russia
[2] Sechenov Univ, Moscow 119991, Russia
基金
俄罗斯基础研究基金会;
关键词
Lumped model; cardiac dynamics; ventricle; auricle; aortic valve; mitral valve; CARDIOVASCULAR-SYSTEM; NUMERICAL-SIMULATION; COMPUTATIONAL MODEL; CARDIAC-MUSCLE; BLOOD-FLOW; PRESSURE;
D O I
10.1515/rnam-2019-0025
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In this work, the lumped parameter model of the left heart is presented. It is based on the concept of the time-varying elastance of myocardium and includes the model of the heart valve dynamics. Comparison of the models with instant and smooth valve opening and closing is given, as well as simulations of pathologies such as mitral valve stenosis and aortic valve insufficiency are addressed.
引用
下载
收藏
页码:289 / 300
页数:12
相关论文
共 50 条
  • [1] Lumped parameter model for computing the minimum pressure during mechanical heart valve closure
    Maines, BH
    Brennen, CE
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (04): : 648 - 655
  • [2] Modeling of aortic valve dynamics in a lumped parameter model of left ventricular-arterial coupling
    Zdravko Virag
    Fabijan Lulić
    ANNALI DELL'UNIVERSITA' DI FERRARA, 2008, 54 (2) : 335 - 347
  • [4] A variable valve area, lumped parameter model of left ventricular filling
    Soans, D
    Szabo, G
    Bolind, C
    Waite, L
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 38, 2002, 38 : 483 - 488
  • [5] Lumped parameter model for hemodynamic simulation of congenital heart diseases
    Shuji Shimizu
    Dai Une
    Toru Kawada
    Yohsuke Hayama
    Atsunori Kamiya
    Toshiaki Shishido
    Masaru Sugimachi
    The Journal of Physiological Sciences, 2018, 68 : 103 - 111
  • [6] Lumped parameter model for hemodynamic simulation of congenital heart diseases
    Shimizu, Shuji
    Une, Dai
    Kawada, Toru
    Hayama, Yohsuke
    Kamiya, Atsunori
    Shishido, Toshiaki
    Sugimachi, Masaru
    JOURNAL OF PHYSIOLOGICAL SCIENCES, 2018, 68 (02): : 103 - 111
  • [7] A variable valve area lumped parameter model of left-ventricular filling
    Szabo, G
    Soans, D
    Graf, A
    Waite, L
    Vahl, CF
    Hagl, S
    EUROPEAN HEART JOURNAL, 2003, 24 : 142 - 142
  • [8] A LUMPED PARAMETER MODEL OF CARDIOVASCULAR SYSTEM WITH PULSATING HEART FOR DIAGNOSTIC STUDIES
    Frolov, S. V.
    Sindeev, S. V.
    Lischouk, V. A.
    Gazizova, D. Sh.
    Liepsch, D.
    Balasso, A.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (03)
  • [9] Sensitivity analysis of a nonlinear lumped parameter model of HIV infection dynamics
    D. M. Bortz
    P. W. Nelson
    Bulletin of Mathematical Biology, 2004, 66 : 1009 - 1026
  • [10] Sensitivity analysis of a nonlinear lumped parameter model of HIV infection dynamics
    Bortz, DM
    Nelson, PW
    BULLETIN OF MATHEMATICAL BIOLOGY, 2004, 66 (05) : 1009 - 1026