INSPECT: a New Approach for Fire Safety in Existing Premises

被引:8
|
作者
Grimaz, Stefano [1 ]
Dattilo, Fabio [2 ]
Maiolo, Alberto [2 ]
机构
[1] Univ Udine, Dipartimento Chim Fis & Ambiente, SPRINT Lab, I-33100 Udine, Italy
[2] Corpo Nazl Vigili Fuoco, Minist Interno, Rome, Italy
关键词
D O I
10.3303/CET1436011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Fire safety in existing premises is one of the major concerns for the Italian National Fire Corps, not only in terms of intervention in the case of fire, but also for determining specific preventive regulations and countermeasures. This concern is based on the fact that the deterministic regulations that are generally used in Italy for defining prescriptions for new premises are not always easily applicable to existing constructions, and because the use of Fire Safety Engineering simulations seems to be too difficult for widespread application. Alternatively, a vulnerability assessment could be more suitable since it aims to identify the strengths and weaknesses of the premises in terms of fire safety. Consequently, the countermeasures for obtaining predefined levels of safety can be determined and customized. The paper illustrates the INSPECT approach (INspection and Study of Potential Emergency-scenarios for Countermeasure Tailoring) designed by the SPRINT-Lab of the University of Udine, and recently used by the Italian Interior Ministry to write new fire safety regulations. In particular, its effectiveness for safety management and emergency planning is underlined.
引用
收藏
页码:61 / +
页数:2
相关论文
共 50 条
  • [1] A new approach to fire safety
    Martin, Chris
    [J]. TCE, 2006, (783): : 20 - 21
  • [2] A simulation approach for ranking of fire safety attributes of existing buildings
    Zhao, CM
    Lo, SM
    Lu, JA
    Fang, Z
    [J]. FIRE SAFETY JOURNAL, 2004, 39 (07) : 557 - 579
  • [3] SAFETY ANALYSIS APPROACH TO EXISTING AND NEW PLANT
    RUPPERT, KA
    [J]. CHEMIE INGENIEUR TECHNIK, 1990, 62 (11) : 916 - 927
  • [4] APPLYING NEW LAWS TO EXISTING BUILDINGS - RETROSPECTIVE FIRE SAFETY CODES
    BRANNIGAN, VM
    [J]. UNIVERSITY OF DETROIT JOURNAL OF URBAN LAW, 1983, 60 (03): : 447 - 472
  • [5] A risk-based approach for assessment and improvement of fire safety in existing buildings
    Bakhtiyari S.
    Khalili R.
    Hosseinpour M.A.
    [J]. Asian Journal of Civil Engineering, 2022, 23 (3) : 391 - 404
  • [6] The adoption of fire safety management for upgrading the fire safety level of existing hotel buildings
    Chen, Ying-Yueh
    Chuang, Ying-Ji
    Huang, Chin-Hsing
    Lin, Ching-Yuan
    Chien, Shen-Wen
    [J]. BUILDING AND ENVIRONMENT, 2012, 51 : 311 - 319
  • [7] A fire safety assessment system for existing buildings
    Lo, SM
    [J]. FIRE TECHNOLOGY, 1999, 35 (02) : 131 - 152
  • [8] A Fire Safety Assessment System for Existing Buildings
    Siu Ming Lo
    [J]. Fire Technology, 1999, 35 : 131 - 152
  • [9] Fire '94 - fire safety in large-scale single-storey retail premises
    Reid, Gerry
    Todd, Colin
    [J]. Fire Prevention, 1994,
  • [10] Applying ALARP in a fire safety analysis in an existing building
    Arnhus, A. H.