Use of Contact Lenses to Optimize OCT Scans of the Optic Nerve in Glaucoma Suspects or Patients with Glaucoma with High Myopia

被引:4
|
作者
Berkenstock, Meghan K. [1 ,2 ]
Parikh, Ruby A. [2 ]
Collins, Melissa D. [1 ]
Ricard, Denise A. [1 ]
Rozar, Sandra R. [1 ]
Castoro, Charles J. [1 ]
Scott, Adrienne W. [1 ,3 ]
机构
[1] Johns Hopkins Univ, Wilmer Lye Inst, Sch Med, Bel Air, MD USA
[2] Johns Hopkins Univ, Ocular Immunol Div, Wilmer Eye Inst, Sch Med, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ, Wilmer Eye Inst, Retina Div, Sch Med, Baltimore, MD 21287 USA
来源
OPHTHALMOLOGY GLAUCOMA | 2020年 / 3卷 / 03期
关键词
FIBER LAYER THICKNESS; COHERENCE TOMOGRAPHY; FUNDUS; POWER; SIZE;
D O I
10.1016/j.ogla.2020.01.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Patients with myopia are at increased risk for the development of glaucoma. The inability to correct for axial length on spectral-domain (SD) OCT translates into lower signal strength and scan reliability in patients with high axial myopia. We evaluated the effectiveness of a contact lens to increase the signal strength and to assess optic nerve dimensions and nerve fiber layer (NFL) thickness using SD OCT in patients with glaucoma or who are glaucoma suspects with high axial myopia. Design: Single-center, prospective, interventional study. Participants: Patients with axial lengths of more than 25.5 mm with a diagnosis of glaucoma or glaucoma suspect. Methods: The optic nerve cube 200x200 scan using the Cirrus SD OCT 400 (Carl Zeiss Meditec, Inc., Dublin, CA) was carried out first without the use of a contact lens and then repeated with placement of the contact lens to correct for the spherical equivalent of the refractive error. Main Outcome Measures: The primary outcome measure was the change in the average NFL thickness before and after use of the contact lens. Secondary outcome measures included the changes in cup volume, disc area, and rim area on OCT. Results: Twelve patients were recruited (20 eyes); the average axial length was 27.06 mm, and the average signal strength interval increased by 1.73 (P = 0.001). With the use of a contact lens, the average NFL thickness was significantly thicker. None of the changes in the secondary outcome measures were significant: rim area, cup volume, or disc area. Conclusions: Based on our data, the use of a contact lens statistically improved the signal strength and average NFL thickness of the SD OCT scan. The ability to capture the perimeter of the optic disc accurately can be limited in the setting of peripapillary atrophy, which was present in all but 2 participants. Future studies with a larger number of participants and a wider range of axial myopia to discern if contact lens correction has a greater effect on the highest axial lengths are needed. (C) 2020 by the American Academy of Ophthalmology
引用
收藏
页码:196 / 201
页数:6
相关论文
共 50 条
  • [1] OCT Angiography of the Glaucoma Optic Nerve
    Lommatzsch, C.
    Koch, J. M.
    Claussnitzer, H.
    Heinz, C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2018, 235 (02) : 205 - 211
  • [2] Hypodense Regions (Holes) in the Retinal Nerve Fiber Layer in Frequency-Domain OCT Scans of Glaucoma Patients and Suspects
    Xin, Daiyan
    Talamini, Christine L.
    Raza, Ali S.
    de Moraes, Carlos Gustavo V.
    Greenstein, Vivienne C.
    Liebmann, Jeffrey M.
    Ritch, Robert
    Hood, Donald C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (10) : 7180 - 7186
  • [3] Glaucoma and optic nerve drusen: Limitations of optic nerve head OCT
    Poli, M.
    Colange, J.
    Goutagny, B.
    Sellem, E.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2017, 40 (07): : 542 - 546
  • [4] High myopia and glaucoma: color Doppler imaging of the optic nerve vasculature
    Montanari, P
    Marangoni, P
    Pinotti, D
    Sinigaglia, L
    Ratiglia, R
    Raiteri, M
    Berardinelli, L
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1999, 77 : 42 - 43
  • [5] Optic neuropathy in high myopia: Glaucoma or high myopia or both?
    Zhang, Xiulan
    Jiang, Jingwen
    Kong, Kangjie
    Li, Fei
    Chen, Shida
    Wang, Peiyuan
    Song, Yunhe
    Lin, Fengbin
    Lin, Timothy P. H.
    Zangwill, Linda M.
    Ohno-Matsui, Kyoko
    Jonas, Jost B.
    Weinreb, Robert N.
    Lam, Dennis S. C.
    PROGRESS IN RETINAL AND EYE RESEARCH, 2024, 99
  • [6] Standardization of High Myopia Optic Nerve Head Abnormalities May Help Diagnose Glaucoma in High Myopia
    Lin, Timothy P. H.
    Radke, Nishant V.
    Chan, Poemen P.
    Tham, Clement C.
    Lam, Dennis S. C.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2023, 12 (05): : 425 - 426
  • [7] Diagnostic Accuracy of Optic Nerve Head and Macula OCT Parameters for Detecting Glaucoma in Eyes With and Without High Axial Myopia
    Rezapour, Jasmin
    Walker, Evan
    Belghith, Akram
    Bowd, Christopher
    Fazio, Massimo A.
    Jiravarnsirikul, Anuwat
    Hyman, Leslie
    Jonas, Jost B.
    Weinreb, Robert N.
    Zangwill, Linda M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 266 : 77 - 91
  • [8] Combining Structural OCT and OCT-Angiography to Discriminate among Glaucoma Patients, Glaucoma Suspects, and Healthy Subjects
    Rabiolo, Alessandro
    Fantaguzzi, Federico
    Gelormini, Francesco
    Sacconi, Riccardo
    Triolo, Giacinto
    Bettin, Paolo
    Anand, Nitin
    McNaught, Andrew
    Querques, Giuseppe
    Bandello, Francesco
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [9] Nerve fiber layer assessment with scanning laser polarimetry in glaucoma patients and glaucoma suspects
    Özdek, SC
    Önol, M
    Hasanreisoglu, B
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2001, 11 (02) : 139 - 144
  • [10] Variability in Optic Nerve Head Morphology in High Axial Myopia and Its Association with Glaucoma
    Seo, Jeong Hyun
    Lee, Seung Hyen
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2024, 65 (10): : 665 - 674