摘要
The removal of power line interference (PLI) and baseline wander (BW) is an essential task for the analysis of the ECG signal. This paper presents a new method to suppress PLI and BW from electrocardiogram (ECG) signals using a hybrid approach of empirical mode decomposition (EMD) and empirical wavelet transform (EWT). The proposed method consists of four stages: EMD-based ECG signal decomposition, construction of high and lowfrequency sub-signals based on the ratio of the zero crossing numbers (RZCN), estimation of PLI and BW through using EWT, and the interference subtraction. The proposed method is tested and validated through experiments performed over a wide variety of real ECG signals which are available on the MIT-BIH arrhythmia database. The results show that the proposed method can effectively remove PLI and BW without distorting the ECG signal components. The efficacy of the proposed method is compared with some of the state-of-the-art methods in terms of output signal-to-noise ratio (SNRo), cross-correlation coefficient (rho), percent root mean square difference (PRD), and weighted diagnostic distortion (WDD) at a different input signal-to-noise ratio (SNRi). The qualitative and quantitative results show that the proposed method outperforms the existing methods.
引用
收藏
页数:34
相关论文
共 50 条
  • [1] A new method for removal of baseline wander and power line interference in ECG signals
    Zhao, Zhi-Dong
    Chen, Yu-Quan
    [J]. PROCEEDINGS OF 2006 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2006, : 4342 - +
  • [2] Power-line interference and baseline wander elimination in ECG using VMD and EWT
    Mir, Haroon Yousuf
    Singh, Omkar
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023,
  • [3] Baseline Wander and Power-Line Interference Removal from ECG Signals Using Fourier Decomposition Method
    Singh, Pushpendra
    Srivastava, Ishita
    Singhal, Amit
    Gupta, Anubha
    [J]. MACHINE INTELLIGENCE AND SIGNAL ANALYSIS, 2019, 748 : 25 - 36
  • [4] Baseline wander and power line interference removal from ECG signals using eigenvalue decomposition
    Sharma, Rishi Raj
    Pachori, Ram Bilas
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 45 : 33 - 49
  • [5] Power line interference and baseline wander removal from ECG signals using local characteristic decomposition
    Dorostghol, A.
    Maghsoudpour, A.
    Ghaffari, A.
    Nikkhah-Bahrami, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2022, 17 (06)
  • [6] Fractal and EMD based removal of baseline wander and powerline interference from ECG signals
    Agrawal, Sakshi
    Gupta, Anubha
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (11) : 1889 - 1899
  • [7] Baseline Wander Removal for ECG Signals Based on Improved EMD
    Li, Guoquan
    Ullah, S. M. Wali
    Li, Bilu
    Lin, Jinzhao
    Wang, Huiqian
    [J]. PROCEEDINGS OF 2020 IEEE 15TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP 2020), 2020, : 484 - 487
  • [8] Removal of the baseline wander and the power line interference from ECG signals using the Median-Kalman filter
    Nandi, Kiron
    Lahiri, Abhijit
    [J]. FOUNDATIONS AND FRONTIERS IN COMPUTER, COMMUNICATION AND ELECTRICAL ENGINEERING, 2016, : 415 - 419
  • [9] A new method based CEEMDAN for removal of baseline wander and powerline interference in ECG signals
    Yao, Liping
    Pan, Zhongliang
    [J]. OPTIK, 2020, 223
  • [10] An efficient removal of power-line interference and baseline wander from ECG signals by employing Fourier decomposition technique
    Singhal, Amit
    Singh, Pushpendra
    Fatimah, Binish
    Pachori, Ram Bilas
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57