Microwave Vibrometry: Noncontact Vibration and Deformation Measurement Using Radio Signals

被引:9
|
作者
Li, Songxu [1 ]
Xiang, Yuyong [1 ]
Wu, Gaoyang [2 ]
Ren, Zesheng [2 ]
Meng, Guang [3 ,4 ,5 ,6 ,7 ,8 ,9 ]
Peng, Zhike [3 ,10 ,11 ,12 ,13 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Mech Engn, State Key Lab Mech Syst & Vibrat, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, State Key Lab Mech Syst & Vibrat, Mech Engn, Shanghai, Peoples R China
[3] Shanghai Jiao Tong Univ, State Key Lab Mech Syst & Vibrat, Shanghai, Peoples R China
[4] Northwestern Polytech Univ, Vibrat Engn Inst, Xian, Peoples R China
[5] Texas A&M Univ, College Stn, TX USA
[6] Tech Univ Berlin, Berlin, Germany
[7] New South Wales Univ, Sydney, NSW, Australia
[8] Shanghai Jiao Tong Univ, Shanghai, Peoples R China
[9] Sch Mech Engn, Shanghai, Peoples R China
[10] Ningxia Univ, Sch Mech Engn, Yinchuan, Ningxia, Peoples R China
[11] City Univ Hong Kong, Hong Kong, Peoples R China
[12] Cranfield Univ, Cranfield, Beds, England
[13] Univ Sheffield, Sheffield, S Yorkshire, England
关键词
Condition monitoring; Microwave measurement; Accelerometers; Fault diagnosis; Instruments; Vibration measurement; Maintenance engineering;
D O I
10.1109/MIM.2022.9756393
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Vibration and deformation monitoring is essential for condition monitoring and fault diagnosis in various fields, such as structural health monitoring (SHM) and equipment maintenance, in which effective vibration and deformation measurement is highly desired. The accelerometer is one of the most widely used vibration measurement instruments in a contact manner. However, the accelerometer has poor performance due to low-frequency response and low displacement measurement accuracy. What is more, for SHM of large structures, in which a great number of measuring points need to be arranged, the sensor networking is high-cost and time-consuming. Meanwhile, the added mass may affect the inherent characteristics of light structures.
引用
收藏
页码:16 / 26
页数:11
相关论文
共 50 条
  • [1] Noncontact measurement of vibration using airborne ultrasound
    Matar, OB
    Remenieras, JP
    Bruneel, C
    Roncin, A
    Patat, F
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) : 626 - 633
  • [2] Analysis of Vibration and Acoustic Signals for Noncontact Measurement of Engine Rotation Speed
    Shan, Xuansheng
    Tang, Lu
    Wen, He
    Martinek, Radek
    Smulko, Janusz
    SENSORS, 2020, 20 (03)
  • [3] Corneal Deformation Measurement Using Scheimpflug Noncontact Tonometry
    Hon, Ying
    Lam, Andrew K. C.
    OPTOMETRY AND VISION SCIENCE, 2013, 90 (01) : E1 - E8
  • [4] Noncontact sensor for vibration measurement
    Branzalov, PP
    Ivanov, LM
    Pavlov, LI
    NINTH INTERNATIONAL SCHOOL ON QUANTUM ELECTRONICS: LASERS-PHYSICS AND APPLICATIONS, 1996, 3052 : 386 - 389
  • [5] Facial Muscle Activity: High-Sensitivity Noncontact Measurement Using Laser Doppler Vibrometry
    Casaccia, Sara
    Sirevaag, Erik J.
    Frank, Mark G.
    O'Sullivan, Joseph A.
    Scalise, Lorenzo
    Rohrbaugh, John W.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [6] Bending vibration measurement on rotors by laser vibrometry
    Miles, T
    Lucas, M
    Rothberg, S
    OPTICS LETTERS, 1996, 21 (04) : 296 - 298
  • [8] A radio navigation angle measurement method with entangled microwave signals
    Li, X.
    Wu, D. W.
    Wei, T. L.
    Miao, Q.
    Zhu, H. N.
    Yang, Ch. Y.
    AIP ADVANCES, 2018, 8 (06):
  • [9] Noncontact measurement of sub-micrometer ultrasonic vibration by near-field microwave
    Peng, Cuiling
    Chen, Xiaolong
    Huan, Huiting
    Huang, Liping
    Zhan, Jinsong
    Liu, Lixian
    JOURNAL OF APPLIED PHYSICS, 2022, 131 (17)
  • [10] DEVICE FOR OPTICAL NONCONTACT MEASUREMENT OF DEFORMATION
    VOLOVETS, LD
    PUGACHEV, GS
    INDUSTRIAL LABORATORY, 1970, 36 (01): : 135 - &