Voltage stability analysis of wind farm integration into transmission network

被引:0
|
作者
Chi, Yongning [1 ]
Liu, Yanhua [2 ]
Wang, Weisheng [1 ]
Dai, Huizhu [1 ]
机构
[1] China Elect Power Res Inst, Beijing, Peoples R China
[2] North China Elect Power Univ, Beijing, Peoples R China
关键词
wind power integration; wind turbines; induction generator (IG); Doubly Fed Induction Generator (DFIG); dynamic model; load flow; voltage stability;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In some regional grids in China, wind power penetration will increase rapidly because of the abundant wind resources in those areas and the government policy impetus. However, the power system security and stability may be affected due to the higher wind power penetration. Because majority of the wind farms with higher installed capacity intends to be connected into the transmission network of 220kV voltage level, their impacts are becoming more widespread. In the grid impact studies of wind power integration, voltage stability is the mostly concerned problem that will affect the operation and security of wind farms and power grid. In this paper, the detailed wind turbines steady-state model and dynamic model are used to explore the wind power integration impact on voltage stability of the power system; the load flow calculation (P-V curve and V-Q curve) and dynamic contingency study are conducted; the different impacts on voltage stability of integrating wind farms based on different wind turbines technologies are illustrated and the following conclusions are presented: a. Wind turbines equipped with simple induction generator are not provided with reactive power regulation capability. Voltage stability deterioration is mainly due to the large amount of reactive power absorbed by the wind turbine generators during the continuous operation and system contingencies. b. Wind turbines equipped with doubly fed induction generator (DFIG) controlled by the PWM converters are provided with reactive power regulation capability; can absorb or supply reactive power during normal operation. The adverse affect on local network voltage stability is mitigated so that more wind power installed capacity can be incorporated into the grid. c. The transient voltage stability characteristics of wind turbines with DFIG are better than wind turbines with induction generator because of the voltage control capability of the DFIG based wind turbines; The DFIG based wind turbines have a better voltage recovery performance than the DFIG based wind turbines with same rating.
引用
收藏
页码:1133 / +
页数:2
相关论文
共 50 条
  • [1] Intelligent Integration of a Wind Farm to an Utility Power Network with Improved Voltage Stability
    Polisetty, Vamsi K.
    Jetti, Sandhya R.
    Venayagamoorthy, Ganesh K.
    Harley, Ronald G.
    [J]. CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 1128 - 1133
  • [2] Static compensator for maintaining voltage stability of wind farm integration to a distribution network
    Lahacani, N. Aouzellag
    Aouzellag, D.
    Mendil, B.
    [J]. RENEWABLE ENERGY, 2010, 35 (11) : 2476 - 2482
  • [3] Voltage Stability Analysis of Wind Farms Integration Connected to Distribution Network
    Chen, Zilai
    Zhao, Jie
    Zhen, Xiaochen
    Shen, Yang
    Liu, Jiefeng
    Zheng, Ce
    Li, Jiaqi
    Liu, Jingqing
    Ma, Yijie
    [J]. 2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,
  • [4] Coordinated planning of large-scale wind farm integration system and regional transmission network considering static voltage stability constraints
    Gan, Lei
    Li, Gengyin
    Zhou, Ming
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2016, 136 : 298 - 308
  • [5] Influence of a Wind Farm in the Dynamic Voltage Stability of a Power Network
    Monteiro Pereira, R. M.
    Machado Ferreira, C. M.
    Maciel Barbosa, F. P.
    [J]. UPEC: 2009 44TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, 2009, : 658 - +
  • [6] Wind Farm Optimal Grid Integration based on Voltage Stability Assessment
    Toma, Radu
    Gavrilas, Mihai
    [J]. 2019 11TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2019,
  • [7] Analysis of Capacitive Voltage Transformer Transients with Wind Farm Integration
    Mahadanaarachchi, Viraj Pradeep
    Ramakumar, Rama
    [J]. 2009 POWER SYSTEMS CONFERENCE, 2009, : 214 - 221
  • [8] Voltage Stability in Power Network when connected Wind Farm Generators
    Boonchiam, P. N.
    Sode-Yome, A.
    Mithulananthan, N.
    Aodsup, K.
    [J]. 2009 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, 2009, : 1474 - +
  • [9] Impact of Renewable energy control center on Voltage stability and transmission network efficiency in Wind farm integrated Grid
    Sekhar, K. Ramachandra
    Kumar, N. Vinoth
    Harada, Yasushi
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2014,
  • [10] Transmission support using Wind Farm controls during voltage stability emergencies
    Vournas, Costas
    Anagnostopoulos, Ioannis
    Souxes, Theodoros
    [J]. CONTROL ENGINEERING PRACTICE, 2017, 59 : 100 - 110