Planning target volume margins for prostate radiotherapy using daily electronic portal imaging and implanted fiducial markers

被引:44
|
作者
Skarsgard, David [1 ,2 ]
Cadman, Pat [3 ]
El-Gayed, Ali [4 ]
Pearcey, Robert [5 ]
Tai, Patricia [6 ]
Pervez, Nadeem [5 ]
Wu, Jackson [1 ,2 ]
机构
[1] Tom Baker Canc Clin, Dept Radiat Oncol, Calgary, AB T2N 4N2, Canada
[2] Univ Calgary, Calgary, AB T2N 4N2, Canada
[3] Saskatoon Canc Ctr, Dept Med Phys, Saskatoon, SK S7N 4H4, Canada
[4] Saskatoon Canc Ctr, Dept Radiat Oncol, Saskatoon, SK S7N 4H4, Canada
[5] Cross Canc Inst, Dept Radiat Oncol, Edmonton, AB T6G 1Z2, Canada
[6] Allan Blair Canc Ctr, Dept Radiat Oncol, Regina, SK S4T 7T1, Canada
来源
RADIATION ONCOLOGY | 2010年 / 5卷
关键词
CONFORMAL RADIOTHERAPY; INTRAFRACTION MOTION; RADIATION-THERAPY; CANCER PATIENTS; DOSE-RESPONSE; INTERFRACTION; TRIAL; VERIFICATION; POSITION; ERROR;
D O I
10.1186/1748-717X-5-52
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Fiducial markers and daily electronic portal imaging (EPI) can reduce the risk of geographic miss in prostate cancer radiotherapy. The purpose of this study was to estimate CTV to PTV margin requirements, without and with the use of this image guidance strategy. Methods: 46 patients underwent placement of 3 radio-opaque fiducial markers prior to prostate RT. Daily pretreatment EPIs were taken, and isocenter placement errors were corrected if they were >= 3 mm along the left-right or superior-inferior axes, and/or >= 2 mm along the anterior-posterior axis. During-treatment EPIs were then obtained to estimate intra-fraction motion. Results: Without image guidance, margins of 0.57 cm, 0.79 cm and 0.77 cm, along the left-right, superior-inferior and anterior-posterior axes respectively, are required to give 95% probability of complete CTV coverage each day. With the above image guidance strategy, these margins can be reduced to 0.36 cm, 0.37 cm and 0.37 cm respectively. Correction of all isocenter placement errors, regardless of size, would permit minimal additional reduction in margins. Conclusions: Image guidance, using implanted fiducial markers and daily EPI, permits the use of narrower PTV margins without compromising coverage of the target, in the radiotherapy of prostate cancer.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Planning target volume margins for prostate radiotherapy using daily electronic portal imaging and implanted fiducial markers
    David Skarsgard
    Pat Cadman
    Ali El-Gayed
    Robert Pearcey
    Patricia Tai
    Nadeem Pervez
    Jackson Wu
    [J]. Radiation Oncology, 5
  • [2] Planning target volume margins for prostate radiotherapy using daily electronic portal imaging and implanted fiducial markers
    Skarsqard, D.
    Cadman, P.
    Wilkinson, M.
    Wu, J.
    Newcomb, C.
    Pearcey, R.
    Murray, B.
    [J]. EJC SUPPLEMENTS, 2005, 3 (02): : 239 - 239
  • [3] Evaluation of target volume margins for radiotherapy of prostate implanted with fiducial markers
    Radwa Fawzy
    Raafat Abdel-Malek
    Mohamed Metwaly
    Omar Abdelaziz
    Ahmed Seleem
    [J]. Radiological Physics and Technology, 2020, 13 : 152 - 159
  • [4] Evaluation of target volume margins for radiotherapy of prostate implanted with fiducial markers
    Fawzy, Radwa
    Abdel-Malek, Raafat
    Metwaly, Mohamed
    Abdelaziz, Omar
    Seleem, Ahmed
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (02) : 152 - 159
  • [5] Reduction of planning target volume margins for prostate cancer radiotherapy on helical tomotherapy using implanted fiducial markers and daily image-guidance
    Drozdz, S.
    Schwedas, M.
    Wendt, T. G.
    [J]. ONCOLOGY RESEARCH AND TREATMENT, 2014, 37 : 64 - 64
  • [6] CHARACTERIZATION OF TARGET VOLUME CHANGES DURING BREAST RADIOTHERAPY USING IMPLANTED FIDUCIAL MARKERS AND PORTAL IMAGING
    Harris, Emma J.
    Donovan, Ellen M.
    Yarnold, John R.
    Coles, Charlotte E.
    Evans, Philip M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (03): : 958 - 966
  • [7] Daily online localization using implanted fiducial markers and its impact on planning target volume for carcinoma prostate
    Khosa, Robin
    Nangia, Sapna
    Chufal, Kundan S.
    Ghosh, D.
    Kaul, Rakesh
    Sharma, Lalit
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2010, 6 (02) : 172 - 178
  • [8] Intensity-modulated radiotherapy using implanted fiducial markers with daily portal imaging: Assessment of prostate organ motion
    Chen, Jergin
    Lee, R. Jeffrey
    Handrahan, Diana
    Sause, William T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03): : 912 - 919
  • [9] Tracking target position variability using intraprostatic fiducial markers and electronic portal imaging in prostate cancer radiotherapy
    Munoz, F.
    Fiandra, C.
    Franco, P.
    Guarneri, A.
    Ciammella, P.
    De Stefanis, P.
    Rondi, N.
    Moretto, F.
    Badellino, S.
    Iftode, C.
    Ragona, R.
    Ricardi, U.
    [J]. RADIOLOGIA MEDICA, 2012, 117 (06): : 1057 - 1070
  • [10] Daily on-line target positioning of prostate external beam radiotherapy with implanted markers and an electronic portal imaging device
    Kruse, J
    Herman, M
    Prisciandaro, J
    Hagness, C
    Davis, B
    Pisansky, T
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1309 - 1309