Variability in Reading Low-Dose Chest CT: Individual Readers vs. Central Review in a Nationwide Lung Cancer Screening Project

被引:0
|
作者
Hwang, E. J. [1 ]
Goo, J. M. [2 ]
Yoon, S. H. [1 ]
Kim, H. Y. [3 ]
Kim, Y. [3 ]
Yi, J. [4 ]
机构
[1] Seoul Natl Univ Hosp, Seoul, South Korea
[2] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul, South Korea
[3] Natl Canc Ctr, Goyang Si, Gyeonggi Do, South Korea
[4] Coreline Soft Co, Seoul, South Korea
关键词
Variability; lung cancer screening; Low dose chest CT;
D O I
10.1016/j.jtho.2019.08.1716
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
P2.11-16
引用
收藏
页码:S798 / S799
页数:2
相关论文
共 50 条
  • [1] Variability in interpretation of low-dose chest CT using computerized assessment in a nationwide lung cancer screening program: comparison of prospective reading at individual institutions and retrospective central reading
    Hwang, Eui Jin
    Goo, Jin Mo
    Kim, Hyae Young
    Yoon, Soon Ho
    Jin, Gong Yong
    Yi, Jaeyoun
    Kim, Yeol
    EUROPEAN RADIOLOGY, 2021, 31 (05) : 2845 - 2855
  • [2] Variability in interpretation of low-dose chest CT using computerized assessment in a nationwide lung cancer screening program: comparison of prospective reading at individual institutions and retrospective central reading
    Eui Jin Hwang
    Jin Mo Goo
    Hyae Young Kim
    Soon Ho Yoon
    Gong Yong Jin
    Jaeyoun Yi
    Yeol Kim
    European Radiology, 2021, 31 : 2845 - 2855
  • [3] Lung Cancer Screening With Low-Dose CT
    Gjermundson, Hali J.
    Clark, Kevin R.
    RADIOLOGIC TECHNOLOGY, 2019, 90 (04) : 336 - 343
  • [4] SCREENING FOR LUNG CANCER WITH LOW-DOSE CT
    Coche, E.
    JBR-BTR, 2008, 91 (01): : 1 - 5
  • [5] Lung cancer screening with low-dose CT
    Diederich, S
    Wormanns, D
    Heindel, W
    EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (01) : 2 - 7
  • [6] Low-dose CT for lung cancer screening
    Bach, Peter B.
    Brawley, Otis W.
    Silvestri, Gerard A.
    LANCET ONCOLOGY, 2018, 19 (03): : E133 - E134
  • [7] Low-Dose CT for Lung Cancer Screening
    Kalra, Mannudeep K.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (05) : 719 - 720
  • [8] Systematic review of baseline low-dose CT lung cancer screening
    Yau, Gary
    Lock, Michael
    Rodrigues, George
    LUNG CANCER, 2007, 58 (02) : 161 - 170
  • [9] Optimum diameter threshold for lung nodules at baseline lung cancer screening with low-dose chest CT: exploration of results from the Korean Lung Cancer Screening Project
    Eui Jin Hwang
    Jin Mo Goo
    Hyae Young Kim
    Jaeyoun Yi
    Yeol Kim
    European Radiology, 2021, 31 : 7202 - 7212
  • [10] Optimum diameter threshold for lung nodules at baseline lung cancer screening with low-dose chest CT: exploration of results from the Korean Lung Cancer Screening Project
    Hwang, Eui Jin
    Goo, Jin Mo
    Kim, Hyae Young
    Yi, Jaeyoun
    Kim, Yeol
    EUROPEAN RADIOLOGY, 2021, 31 (09) : 7202 - 7212