A new strategy to design label-free electrochemical biosensor for ultrasensitive diagnosis of CYFRA 21-1 as a biomarker for detection of non-small cell lung cancer

被引:50
|
作者
Jafari-Kashi, Abbas [1 ]
Rafiee-Pour, Hossain-Ali [2 ]
Shabani-Nooshabadi, Mehdi [1 ,3 ]
机构
[1] Univ Kashan, Fac Chem, Dept Analyt Chem, Kashan, Iran
[2] Univ Kashan, Fac Chem, Dept Cell & Mol Biol, Kashan, Iran
[3] Univ Kashan, Inst Nano Sci & Nano Technol, Kashan, Iran
关键词
CYFRA21-1; Electrochemical biosensor; Lung cancer; Guanine oxidation; Label-free; COMPOSITE THIN-FILM; GRAPHENE OXIDE; DNA BIOSENSOR; NANOPARTICLES; FABRICATION; MARKER; ASSAY;
D O I
10.1016/j.chemosphere.2022.134636
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Lung cancer is one of the most dangerous cancers with high mortality rate among other cancers therefore, early detection of this cancer is very important. Many studies have been reported in ways of diagnostic lung cancer early. According to reports, one of the most important biomarkers to detect lung cancer is Cytokeratin 19 fragment 21-1 (CYFRA21-1), which is significantly related to non-small cell lung cancer, in particular, squamous cell carcinoma. Thus, finding a new method for the early diagnosis of CYFRA 21-1 (DNA target probe) is essential. In the present report, we design a novel label-free electrochemical DNA-biosensor related to the signal of guanine oxidation. The proposed DNA biosensor is fabricated by a modified glassy carbon electrode (GCE) with reduced-graphene oxide (rGO), poly pyrrole (PPy), silver nanoparticles (AgNPs) and single-strand DNA (ssDNA as capture probe) GCE/rGO/PPy/AgNPs/ssDNA. The differential pulse voltammetry (DPV) and cyclic voltammetry (CV) techniques are used to verify the hybridization process between capture and target probes. Electrochemical impedance spectroscopy (EIS), energy diffraction X-ray (EDX) and field-emission scanning microscopy (FE-SEM) techniques are applied to the characterization of different modified GCE surfaces as well as Xray diffraction (XRD) for graphene oxide synthesis. The XRD pattern of the synthesized GO that its diffraction peak appears at 10.2. The applied CV and DPV for the guanine oxidation are determined under optimal conditions. The label-free DNA biosensor showed a great result for the determination of CYFRA21-1 with a wide linear range from two consecutive linear relationships of peak current and CYFRA21-1 concentration were found(1.0 x 10(-14) -1.0 x 10(-10) M, R-2 = 0.9936 and 1.0 x 10(-9) -1.0 x 10(-6) M, R-2 = 0.9955). Proposed electrochemical biosensor displayed low detection limit (2.4 fM).
引用
收藏
页数:8
相关论文
共 50 条
  • [1] CYFRA 21-1 is a suitable marker in the diagnosis of non-small cell lung cancer
    Oremek, GM
    Seiffert, UB
    MEDIZINISCHE WELT, 1996, 47 (08): : 335 - 338
  • [2] Ultrasensitive label-free detection for lung cancer CYFRA 21-1 DNA based on ring-opening polymerization
    Li, Xiaofei
    Zhang, Yawen
    Hao, Lulu
    Liu, Yanju
    Wang, Xia
    Yang, Huaixia
    Kong, Jinming
    TALANTA, 2021, 223
  • [3] A sandwich-type electrochemical immunoassay for ultrasensitive detection of non-small cell lung cancer biomarker CYFRA21-1
    Zeng, Yan
    Bao, Jing
    Zhao, Yanan
    Huo, Danqun
    Chen, Mei
    Qi, Yanli
    Yang, Mei
    Fa, Huanbao
    Hou, Changjun
    BIOELECTROCHEMISTRY, 2018, 120 : 183 - 189
  • [4] CYFRA 21-1 in non-small cell lung cancer - Standardisation and application during diagnosis
    Pavicevic, Radomir
    Bubanovic, Gordana
    Franjevic, Ana
    Stancic-Rokotov, Dinko
    Samarzija, Miroslav
    COLLEGIUM ANTROPOLOGICUM, 2008, 32 (02) : 485 - 498
  • [5] Prognostic significance of CYFRA 21-1 in non-small cell lung cancer
    Hirashima, T
    Takada, M
    Komiya, T
    Nitta, T
    Masashi, K
    Masuda, N
    Matui, K
    Kikui, M
    Yasumitsu, T
    Kawase, I
    ANTICANCER RESEARCH, 1998, 18 (6B) : 4713 - 4716
  • [6] Metal-free Photochemically Mediated ATRP for Ultrasensitive Quantification of CYFRA 21-1 for Detection of Early Stage Non-Small Cell Lung Cancer
    Si, Fuchun
    Sun, Yuzhi
    Ba, Yanyan
    Guo, Liang
    Liu, Yanju
    Kong, Jinming
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (09)
  • [7] Serum CYFRA 21-1 as a biomarker of pemetrexed plus cisplatin treatment in nonsquamous non-small cell lung cancer
    Sakatani, Toshio
    Ohyanagi, Fumiyoshi
    Tanimoto, Azusa
    Kawano, Yuko
    Saito, Ryota
    Kaburaki, Kyohei
    Yanagitani, Noriko
    Kudo, Keita
    Horiike, Atsushi
    Hagiwara, Sachiko
    Horai, Takeshi
    Nishio, Makoto
    JOURNAL OF CLINICAL ONCOLOGY, 2012, 30 (15)
  • [8] CYFRA 21-1 is the most sensitive tumor marker in non-small cell lung cancer
    Yasasever, V
    Dincer, M
    Camlyca, H
    Karaloolu, D
    Kizir, A
    Topuz, E
    Dalay, N
    JOURNAL OF TUMOR MARKER ONCOLOGY, 1997, 12 (02): : 135 - 140
  • [9] Multifunctional substrate of label-free electrochemical immunosensor for ultrasensitive detection of cytokeratins antigen 21-1
    Wang, Huiqiang
    Gao, Xin
    Ma, Zhanfang
    SCIENTIFIC REPORTS, 2017, 7
  • [10] Multifunctional substrate of label-free electrochemical immunosensor for ultrasensitive detection of cytokeratins antigen 21-1
    Huiqiang Wang
    Xin Gao
    Zhanfang Ma
    Scientific Reports, 7