New Metrics Needed in the Evaluation of Hearing Hazard Associated With Industrial Noise Exposure

被引:29
|
作者
Zhang, Meibian [1 ]
Xie, Hongwei [1 ]
Zhou, Jiena [1 ]
Sun, Xin [2 ]
Hu, Weijiang [2 ]
Zou, Hua [1 ]
Zhou, Lifang [1 ]
Li, Jingsong [3 ]
Zhang, Ming [4 ]
Kardous, Chucri A. [5 ]
Morata, Thais C. [5 ]
Murphy, William J. [5 ]
Zhang, Jane Hongyuan [6 ]
Qiu, Wei [7 ]
机构
[1] Zhejiang Prov Ctr Dis Control & Prevent, Hangzhou 310051, Zhejiang, Peoples R China
[2] Natl Inst Occupat Hlth & Poison Control, Beijing, Peoples R China
[3] Zhejiang Univ, Coll Biomed Engn & Instrument Sci, Key Lab Biomed Engn, Minist Educ, Hangzhou, Peoples R China
[4] Tianjing Ctr Dis Control & Prevent, Tianjin, Peoples R China
[5] Natl Inst Occupat Safety & Hlth, Div Field Studies & Engn, Noise & Bioacoust Team, Cincinnati, OH 45226 USA
[6] Yale Univ, Yale Sch Publ Hlth, New Haven, CT USA
[7] SUNY Coll Plattsburgh, Auditory Res Lab, 101 Broad St, Plattsburgh, NY 12901 USA
来源
EAR AND HEARING | 2021年 / 42卷 / 02期
关键词
Occupational noise exposure; ISO; 1999; model; Gaussian noise; Non-Gaussian noise; Kurtosis; Noise-induced permanent threshold shift;
D O I
10.1097/AUD.0000000000000942
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: To evaluate (1) the accuracy of the International Organization for Standardization (ISO) standard ISO 1999 [(2013), International Organization for Standardization, Geneva, Switzerland] predictions of noise-induced permanent threshold shift (NIPTS) in workers exposed to various types of high-intensity noise levels, and (2) the role of the kurtosis metric in assessing noise-induced hearing loss (NIHL). Design: Audiometric and shift-long noise exposure data were acquired from a population (N = 2,333) of screened workers from 34 industries in China. The entire cohort was exclusively divided into subgroups based on four noise exposure levels (85 <= L-Aeq.8h < 88, 88 <= L-Aeq.8h < 91, 91 <= L-Aeq.8h < 94, and 94 <= L-Aeq.8h <= 100 dBA), two exposure durations (D <= 10 years and D > 10 years), and four kurtosis categories (Gaussian, low-, medium-, and high-kurtosis). Predicted NIPTS was calculated using the ISO 1999 model for each participant and the actual measured NIPTS was corrected for age and sex also using ISO 1999. The prediction accuracy of the ISO 1999 model was evaluated by comparing the NIPTS predicted by ISO 1999 with the actual NIPTS. The relation between kurtosis and NIPTS was also investigated. Results: Overall, using the average NIPTS value across the four audiometric test frequencies (2, 3, 4, and 6 kHz), the ISO 1999 predictions significantly (p < 0.001) underestimated the NIPTS by 7.5 dB on average in participants exposed to Gaussian noise and by 13.6 dB on average in participants exposed to non-Gaussian noise with high kurtosis. The extent of the underestimation of NIPTS by ISO 1999 increased with an increase in noise kurtosis value. For a fixed range of noise exposure level and duration, the actual measured NIPTS increased as the kurtosis of the noise increased. The noise with kurtosis greater than 75 produced the highest NIPTS. Conclusions: The applicability of the ISO 1999 prediction model to different types of noise exposures needs to be carefully reexamined. A better understanding of the role of the kurtosis metric in NIHL may lead to its incorporation into a new and more accurate model of hearing loss due to noise exposure.
引用
收藏
页码:290 / 300
页数:11
相关论文
共 50 条
  • [1] CONTRIBUTION TO STUDY OF EVALUATION OF HAZARD OF HEARING-LOSS ACCORDING TO INTENSITY OF NOISE AND LENGTH OF EXPOSURE IN WORKERS EXPOSED TO INDUSTRIAL NOISE
    CHEMIN, P
    DUFY, B
    CHEMIN, A
    ARCHIVES DES MALADIES PROFESSIONNELLES DE MEDECINE DU TRAVAIL ET DE SECURITE SOCIALE, 1974, 35 (10-1): : 893 - 900
  • [2] PROGRESSION OF HEARING LOSS AS A FUNCTION OF INDUSTRIAL NOISE EXPOSURE
    GLORIG, A
    SUMMERFIELD, A
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1959, 31 (01): : 124 - 124
  • [3] EVALUATION OF HEARING IMPAIRMENT DUE TO INDUSTRIAL NOISE
    VONSCHULTHESS, G
    ARCHIVES OF OTOLARYNGOLOGY, 1957, 65 (05): : 512 - 520
  • [4] The value of a kurtosis metric in estimating the hazard to hearing of complex industrial noise exposures
    Auditory Research Laboratory, State University of New York, 107 Beaumont Hall, Plattsburgh, NY 12901, United States
    J. Acoust. Soc. Am., 2013, 5 (2856-2866):
  • [5] The value of a kurtosis metric in estimating the hazard to hearing of complex industrial noise exposures
    Qiu, Wei
    Hamernik, Roger P.
    Davis, Robert I.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (05): : 2856 - 2866
  • [6] TRENDS IN HEARING LOSS ASSOCIATED WITH AGE OR EXPOSURE TO NOISE
    PEARSON, JCG
    SPRENT, P
    THE ROYAL STATISTICAL SOCIETY SERIES C-APPLIED STATISTICS, 1968, 17 (03): : 205 - &
  • [7] Noise exposure associated with hearing aid use in industry
    Dolan, TG
    Maurer, JF
    JOURNAL OF SPEECH AND HEARING RESEARCH, 1996, 39 (02): : 251 - 260
  • [8] Medicolegal significance of asymmetrical hearing loss in cases of industrial noise exposure
    Fernandes, S. V.
    Fernandes, C. M.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2010, 124 (10): : 1051 - 1055
  • [9] DISCUSSION OF TRENDS IN HEARING LOSS ASSOCIATED WITH AGE OR EXPOSURE TO NOISE
    WOOLF, B
    LAWLEY, DN
    HEALY, MJR
    LAWSON, H
    HARDING, EF
    PEARSON, JCG
    SPRENT, P
    THE ROYAL STATISTICAL SOCIETY SERIES C-APPLIED STATISTICS, 1968, 17 (03): : 213 - &
  • [10] Evaluation of the State of Hearing for Different Regimens of Exposure to Noise.
    Zvereva, G.S.
    Rather, M.V.
    Kolganov, A.V.
    Toporets, T.Ya.
    Mar'enko, L.V.
    Meditsina Truda I Promyshlennaya Ekologiya, 1979, (07): : 22 - 26