LIAISON® Treponema assay:: a new automated chemiluminescence immunoassay for syphilis screening.

被引:0
|
作者
Bobba, G.
DuBois, D.
Edinger, J. T.
机构
[1] DiaSorin, Stillwater, OK USA
[2] Univ Pittsburgh, Med Ctr, Pittsburgh, PA USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
B-31
引用
收藏
页码:A62 / A62
页数:1
相关论文
共 50 条
  • [1] Evaluation of LIAISON® Treponema Assay, a new recombinant chemiluminescence immunoassay for the diagnosis of syphilis.
    Bobba, G.
    Marangoni, A.
    Pallavicini, L.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A38 - A39
  • [2] Evaluation of the LIAISON chemiluminescence immunoassay for diagnosis of syphilis
    Knight, Carrie S.
    Crum, Mary A.
    Hardy, Robert W.
    CLINICAL AND VACCINE IMMUNOLOGY, 2007, 14 (06) : 710 - 713
  • [3] Evaluation of LIAISON treponema screen, a novel recombinant antigen-based chemiluminescence immunoassay for laboratory diagnosis of syphilis
    Marangoni, A
    Sambri, V
    Accardo, S
    Cavrini, F
    D'Antuono, A
    Moroni, A
    Storni, E
    Cevenini, R
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2005, 12 (10) : 1231 - 1234
  • [4] The Architect Syphilis assay for antibodies to Treponema pallidum: an automated screening assay with high sensitivity in primary syphilis
    Young, H.
    Pryde, J.
    Duncan, L.
    Dave, J.
    SEXUALLY TRANSMITTED INFECTIONS, 2009, 85 (01) : 19 - 23
  • [5] Evaluation of two automated chemiluminescence immunoassays, the LIAISON Treponema Screen and the ARCHITECT Syphilis TP, and the Treponema pallidum particle agglutination test for laboratory diagnosis of syphilis
    Wellinghausen, Nele
    Dietenberger, Hanna
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (08) : 1375 - 1377
  • [6] Clinical evaluation of the LIAISON® Borrelia burgdorferi assay, a new automated chemiluminescence immunoassay for the diagnosis of lyme disease.
    Bobba, G.
    Terhaar, P. J.
    Blocki, F. A.
    Schmidt, J. A.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A64 - A64
  • [7] LIAISON® ACTH, an automated chemiluminescence immunoassay for the use on the fully automated LIAISON random access immunoassay analyzer.
    Schlett, R
    Ivankovic, B
    Gehrke, W
    Mack, M
    CLINICAL CHEMISTRY, 2003, 49 (06) : A43 - A44
  • [8] Analytical Comparison of the Architect Syphilis TP and Liaison Treponema Automated Chemiluminescent Immunoassays and Their Performance in a Reverse Syphilis Screening Algorithm
    Sanfilippo, Alan M.
    Freeman, Kristie
    Schmitz, John L.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (08)
  • [9] Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method
    Chen, Qixia
    An, Jingna
    Rao, Chenli
    Wang, Tingting
    Li, Dongdong
    Feng, Shu
    Tao, Chuanmin
    CLINICAL LABORATORY, 2016, 62 (04) : 519 - 526
  • [10] Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various stages of syphilis
    Ebel, A
    Bachelart, L
    Alonso, JM
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (02) : 358 - 361