Two-body wear rate of PEEK, CAD/CAM resin composite and PMMA: Effect of specimen geometries, antagonist materials and test set-up configuration

被引:79
|
作者
Wimmer, Timea [1 ]
Huffmann, Anne Mildred Sophie [1 ]
Eichberger, Marlis [1 ]
Schmidlin, Patrick R. [2 ]
Stawarczyk, Bogna [1 ]
机构
[1] Univ Munich, Dept Prosthodont, Sch Dent, Goethestr 70, D-80336 Munich, Germany
[2] Univ Zurich, Clin Prevent Dent Periodontol & Cariol, Ctr Dent Med, Plattenstr 11, CH-8032 Zurich, Switzerland
关键词
PEEK; Composite; CAD/CAM; Two-body wear; Enamel; Crown; Flat specimens; FIXED DENTAL PROSTHESES; TENSILE BOND STRENGTH; LOAD-BEARING CAPACITY; IN-VITRO; PROSTHODONTIC MATERIALS; RESTORATIVE MATERIALS; VENEERING RESINS; MARTENS HARDNESS; DENTURE TEETH; CROWNS;
D O I
10.1016/j.dental.2016.03.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To test and compare the two-body wear rate of three CAD/CAM polymer materials and the influence of specimen geometry, antagonist material and test set-up configuration. Methods. Three CAD/CAM polymeric materials were assessed: a thermoplastic polyetheretherketone (PEEK), an experimental nanohybrid composite (COMP) and a PMMA-based material (PMMA). Crown-shaped and flat specimens were prepared from each material. The specimens underwent thermo-mechanical loading (50 N, 5/55 degrees C; 600,000 chewing cycles) opposed to human enamel and stainless steel antagonists. Half of the specimens of each group were loaded with a sliding movement of 0.7 mm, the remaining half without. Thereby, 24 different test set-ups were investigated (n=12). Wear of the materials and antagonists was evaluated with a match-3D procedure. The topography of all surfaces was examined with scanning electron microscopy (SEM). Data were statistically evaluated with four-/one-way ANOVA followed by Scheffe post hoc test and unpaired t-test (p < 0.05). Results. All PEEK specimens showed significantly less material loss than COMP and PMMA specimens when loaded laterally. Within the axial loaded groups this was only true for the flat specimens tested with enamel antagonists. Crown specimens of these groups exhibited lower loss values than flat ones. Lateral force application led mostly to significantly higher material loss than the axial load application. On the antagonist side, no impact of CAD/CAM polymer material, antagonist material, force application and specimen geometry was found. Significance. Wear of PEEK was lower than that of the resin-based materials when lateral forces were applied, but showed comparable antagonist wear rates at the same time. (C) 2016 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E127 / E136
页数:10
相关论文
共 2 条
  • [1] TWO-BODY WEAR RATE OF CAD/CAM RESIN BLOCKS AND THEIR ENAMEL ANTAGONISTS
    Stawarczyk, Bogna
    Oezcan, Mutlu
    Trottmann, Albert
    Schmutz, Felix
    Roos, Malgorzata
    Haemmerle, Christoph
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (05): : 325 - 332
  • [2] Wear characteristics of esthetic resin matrix and zirconia reinforced lithium disilicate CAD/CAM materials: two-body wear and surface topography analysis
    Radwan, Mohamed M.
    Abdou, Ahmed
    Nagi, Nermeen
    Younes, Dina H.
    Mahrous, Aliaa
    MINERVA DENTAL AND ORAL SCIENCE, 2023, 72 (06) : 280 - 290