Vibration-Induced Errors in MEMS Tuning Fork Gyroscopes with Imbalance

被引:5
|
作者
Fang, Xiang [1 ]
Dong, Linxi [1 ,2 ]
Zhao, Wen-Sheng [1 ]
Yan, Haixia [3 ,4 ]
Teh, Kwok Siong [5 ]
Wang, Gaofeng [1 ]
机构
[1] Hangzhou Dianzi Univ, Coll Elect & Informat, Minist Educ, Key Lab RF Circuits & Syst, Hangzhou 310018, Zhejiang, Peoples R China
[2] Chinese Acad Sci, State Key Lab Funct Mat Informat, Shanghai 200050, Peoples R China
[3] Hangzhou Dianzi Univ, Sch Informat Engn, Dept Mech, Hangzhou 310018, Zhejiang, Peoples R China
[4] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian 710049, Shaanxi, Peoples R China
[5] San Francisco State Univ, Sch Engn, Dept Mech, San Francisco, CA 94132 USA
基金
中国国家自然科学基金;
关键词
vibration; TFG; simulation; imbalance; error output; coupling; FREQUENCY-RESPONSE;
D O I
10.3390/s18061755
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper discusses the vibration-induced error in non-ideal MEMS tuning fork gyroscopes (TFGs). Ideal TFGs which are thought to be immune to vibrations do not exist, and imbalance between two gyros of TFGs is an inevitable phenomenon. Three types of fabrication imperfections (i.e., stiffness imbalance, mass imbalance, and damping imbalance) are studied, considering different imbalance radios. We focus on the coupling types of two gyros of TFGs in both drive and sense directions, and the vibration sensitivities of four TFG designs with imbalance are simulated and compared. It is found that non-ideal TFGs with two gyros coupled both in drive and sense directions (type CC TFGs) are the most insensitive to vibrations with frequencies close to the TFG operating frequencies. However, sense-axis vibrations with in-phase resonant frequencies of a coupled gyros system result in severe error outputs to TFGs with two gyros coupled in the sense direction, which is mainly attributed to the sense capacitance nonlinearity. With increasing stiffness coupled ratio of the coupled gyros system, the sensitivity to vibrations with operating frequencies is cut down, yet sensitivity to vibrations with in-phase frequencies is amplified.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Vibration-induced errors in MEMS tuning fork gyroscopes
    Yoon, Sang Won
    Lee, Sangwoo
    Najafi, Khalil
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 180 : 32 - 44
  • [2] Vibration sensitivity of MEMS tuning fork gyroscopes
    Yoon, Sang Won
    Lee, Sang Woo
    Perkins, N. C.
    Najafi, Khalil
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 115 - 119
  • [3] Analysis of non-stochastic errors in comb-drive tuning fork MEMS gyroscopes
    Li, Rong-Bing
    Liu, Jian-Ye
    Lin, Xue-Yuan
    Hua, Bing
    Liu, Rui-Hua
    Dianzi Keji Daxue Xuebao/Journal of the University of Electronic Science and Technology of China, 2006, 35 (06): : 928 - 931
  • [4] Resilience to vibration of a tuning fork MEMS gyroscope
    Koumela, Alexandra
    Poulain, Christophe
    Le Goc, Carole
    Verdot, Thierry
    Joet, Loic
    Rey, Patrice
    Berthelot, Audrey
    Jourdan, Guillaume
    PROCEEDINGS OF THE 30TH ANNIVERSARY EUROSENSORS CONFERENCE - EUROSENSORS 2016, 2016, 168 : 1725 - 1730
  • [5] Elimination of mechanical and electrostatic coupling errors in quartz tuning fork gyroscopes
    Lu, Wen-Yi
    Cui, Fang
    Feng, Li-Hui
    Sun, Yu-Nan
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2009, 29 (05): : 420 - 422
  • [6] Error sources in in-plane silicon tuning-fork MEMS gyroscopes
    Weinberg, Marc S.
    Kourepenis, Anthony
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (03) : 479 - 491
  • [7] Vibration-induced error of a pendulous MEMS accelerometer
    Lestev, A.M.
    Fedorov, M.V.
    Gyroscopy and Navigation, 2012, 3 (01) : 47 - 50
  • [8] The Effect of Displacement Constraints on the Failure of MEMS Tuning Fork Gyroscopes under Shock Impact
    Lian, Jiangkai
    Li, Jianhua
    Xu, Lixin
    MICROMACHINES, 2019, 10 (05)
  • [9] Tuning vibration-induced emission through macrocyclization and catenation
    Xu, Wei-Tao
    Peng, Zhiyong
    Wu, Peicong
    Jiang, Yefei
    Li, Wei-Jian
    Wang, Xu-Qing
    Chen, Jinquan
    Yang, Hai-Bo
    Wang, Wei
    CHEMICAL SCIENCE, 2024, 15 (19) : 7178 - 7186
  • [10] Structural optimization of Z-axis tuning-fork MEMS gyroscopes for enhancing reliability and resolution
    Zhang, Lihong
    Masek, Vlastimil
    Sanatdoost, Nikoo Naeemi
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2015, 21 (06): : 1187 - 1201