Effects of demineralization on quantitative ultrasound measurements in human cancellous bone.

被引:0
|
作者
Salisbury, KT
Nicholson, PHF
Bouxsein, ML
机构
[1] Beth Israel Deaconess Med Ctr, Dept Orthoped, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
M297
引用
收藏
页码:S527 / S527
页数:1
相关论文
共 50 条
  • [1] Bone marrow influences quantitative ultrasound measurements in human cancellous bone
    Nicholson, PHF
    Bouxsein, ML
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (03): : 369 - 375
  • [2] Do quantitative ultrasound measurements reflect structure independently of density in human vertebral cancellous bone?
    Nicholson, PHF
    Müller, R
    Lowet, G
    Cheng, XG
    Hildebrand, T
    Rüegsegger, P
    Van der Perre, G
    Dequeker, J
    Boonen, S
    BONE, 1998, 23 (05) : 425 - 431
  • [3] Optimized demineralization of human cancellous bone by application of a vacuum
    Eagle, Mark J.
    Rooney, Paul
    Kearney, John N.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (05) : 1023 - 1029
  • [4] Effect of implant fixture length on RFA measurements in cancellous bone.
    Min, K. K.
    Kim, W. B.
    Kim, D. K.
    Sul, Y. T.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B312 - B312
  • [5] Fluoride content, mechanical properties and hardness of human cancellous bone.
    Chachra, D
    Limeback, H
    Gross, AE
    Hutchison, C
    Grynpas, MD
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 904 - 904
  • [6] Quantitative ultrasound does not reflect mechanically induced damage in human cancellous bone
    Nicholson, PHF
    Bouxsein, ML
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (12) : 2467 - 2472
  • [7] Relationships of quantitative ultrasound parameters with cancellous bone microstructure in human calcaneus in vitro
    Wear, Keith A.
    Nagaraja, Srinidhi
    Dreher, Maureen L.
    Gibson, Sheng L.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 131 (02): : 1605 - 1612
  • [8] Frequency domain imaging of cancellous bone.
    Abel, EW
    Wigderowitz, CA
    Rowley, DI
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1182 - 1184
  • [9] Quantitative ultrasound is not sensitive to mechanical damage in cancellous bone
    Nicholson, PHF
    Bouxsein, ML
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 7 - 7
  • [10] Osteodensitometry and ultrasound measurements of bone. Methods, indications, and efficacy
    Kann, PH
    ORTHOPADE, 2001, 30 (07): : 437 - 443