Monte Carlo Simulation Studies of Three-Dimensional Dose Distribution for Polymer Gel Dosimeter and Radiochromic Gel Dosimeter in a Proton Beam

被引:0
|
作者
Park, M.
Kim, G.
Jung, H.
Park, S.
Park, S.
Ji, Y.
Yun, J.
机构
关键词
D O I
10.1118/1.4956295
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-F-T-159
引用
收藏
页码:3498 / 3498
页数:1
相关论文
共 50 条
  • [1] Three-Dimensional Dose Distributions of Incident Proton Particle in the Polymer Gel Dosimeter and the Radiochromic Gel Dosimeter: A Simulation Study with MCNP Code
    Park, M.
    Kim, G.
    Ji, Y.
    Kim, K.
    Park, S.
    Jung, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3510 - 3510
  • [2] Inclusion type radiochromic gel dosimeter for three-dimensional dose verification
    Usui, Shuji
    Yoshioka, Munenori
    Hayashi, Shin-ichiro
    Tominaga, Takahiro
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [3] MonteCarlo Simulation Study of Polymer and Radiochromic Gel for Three-Dimensional Proton Dose Distribution
    Park, M.
    Jung, H.
    Kim, G.
    Ji, Y.
    Kim, K.
    Park, S.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 279 - 279
  • [4] On the development of the VIPAR polymer gel dosimeter for three-dimensional dose measurements
    Kozicki, Marek
    Maras, Piotr
    Rybka, Krzysztof
    Biegafiski, Tadeitsz
    Kadlubowski, Slawomir
    Petrokokkinos, Loukas
    [J]. MACROMOLECULAR SYMPOSIA, 2007, 254 : 345 - 352
  • [5] Three-dimensional dose distributions in a heterogeneous phantom measured by polymer gel dosimeter
    Watanabe, Y
    Perera, G
    Mooij, R
    Maryanski, M
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1371 - 1371
  • [6] Verification of three-dimensional IMRT dose distribution in the inhomogeneous media using a polymer-gel dosimeter
    Dvorak, P
    Spevacek, V
    Novotny, J
    Hrbacek, J
    Bogner, J
    Kroupa, B
    Georg, D
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S339 - S340
  • [7] Enhanced dose measurement of zinc oxide nanoparticles by radiochromic polymer dosimeter and Monte Carlo simulation
    Banaee, Nooshin
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (04) : 515 - 520
  • [8] Three-Dimensional Winston-Lutz Test Using a Reusable Radiochromic Gel Dosimeter
    Ono, K.
    Fujino, K.
    Kinoshita, K.
    Hayashi, S.
    Akagi, Y.
    Hirokawa, Y.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E413 - E414
  • [9] Dose evaluation of a blood irradiator using Monte Carlo simulation and MAGAT gel dosimeter
    Shih, Tian-Yu
    Liu, Yan-Lin
    Chen, Ho-Hsing
    Wu, Jay
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [10] Three-dimensional polymer gel dosimetry:: basic physical properties of the dosimeter
    Novotny, J
    Spevácek, V
    Dvorák, P
    Novotny, J
    Cechák, T
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 255 - 258