The effect of flowable resin composite on microleakage and internal voids in Class II composite restorations

被引:1
|
作者
Ölmez, A [1 ]
Öztas, N [1 ]
Bodur, H [1 ]
机构
[1] Gazi Univ, Dept Pediat Dent, Ankara, Turkey
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This in vitro study evaluated the influence of two flowable resin composites on marginal microleakage and internal voids in Class II composite restorations with the margins below the cementoenamel junction (CEJ). Class II cavities randomly divided into four groups: Group I-Filtek with Filtek Flow lining; Group II-Filtek; Group III-Tetric Ceram with Tetric Flow lining; Group IV-Tetric Ceram. After thermocycling tests (5-60 x 1500) and dye soaking, the teeth were sectioned in a mesiodistal direction along their longitudinal axis. Gingival-marginal microleakage and internal voids in three separate portions of the restoration (interface, cervical and occlusal voids) were observed with a microscope. Statistical analyses indicated that the use of flowable resin composites (Groups I and III) provided a reduction in marginal microleakage and a reduction in some parts of the internal voids or total voids (p < 0.05). The condensable material (Filtek) in combination with the flowable liner showed fewer voids (interface, occlusal, total) than the hybrid resin (Tetric) (p < 0.05). There was a correlation between the number of internal voids or total voids and the marginal microleakage (p < 0.05). It was concluded that a composite lining in a Class II resin composite with margins below the cementoenamel junction may reduce marginal microleakage and voids in the interface and the total number of voids in the restoration.
引用
收藏
页码:713 / 719
页数:7
相关论文
共 50 条
  • [1] Effect of flowable composite lining on microleakage and internal voids in Class II composite restorations
    Korkmaz, Yonca
    Ozel, Emre
    Attar, Nuray
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2007, 9 (02): : 189 - 194
  • [2] Microleakage and internal voids in class II composite restorations with flowable composite linings
    Chuang, SF
    Liu, JK
    Jin, YT
    [J]. OPERATIVE DENTISTRY, 2001, 26 (02) : 193 - 200
  • [3] Effects of flowable composite lining and operator experience on microleakage and internal voids in class II composite restorations
    Chuang, SF
    Liu, JK
    Chao, CC
    Liao, FP
    Chen, YHM
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (02): : 177 - 183
  • [4] Microleakage of Class II resin-based composite restorations with flowable composite in the proximal box
    Jain, P
    Belcher, M
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2000, 13 (05): : 235 - 238
  • [5] Effects of lining materials on microleakage and internal voids of class II resin-based composite restorations
    Chuang, SF
    Jin, YT
    Lin, TS
    Chang, CH
    García-Godoy, F
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2003, 16 (02): : 84 - 90
  • [6] In-vitro microleakage around class II resin restorations lined with flowable composite.
    Duong, THX
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1324 - 1324
  • [7] Microleakage of class II restorations using a flowable composite as a liner.
    Russell, RR
    Mazer, RB
    [J]. JOURNAL OF DENTAL RESEARCH, 1998, 77 : 131 - 131
  • [8] Influence of flowable composite and restorative technique on microleakage of class II restorations
    Hernandes, Natalia M. A. P.
    Catelan, Anderson
    Soares, Giulliana P.
    Ambrosano, Glaucia M. B.
    Lima, Debora A. N. L.
    Marchi, Giselle M.
    Martins, Luis R. M.
    Aguiar, Flavio H. B.
    [J]. JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2014, 5 (04) : 283 - 288
  • [9] The use of flowable composite resin in Class V restorations: microleakage evaluation.
    Mazer, RB
    Russell, RR
    [J]. JOURNAL OF DENTAL RESEARCH, 1998, 77 : 131 - 131
  • [10] Compomer effect on microleakage in Class II composite resin restorations.
    Bahram, R
    Aboushala, A
    Kugel, G
    Perry, R
    [J]. JOURNAL OF DENTAL RESEARCH, 1997, 76 : 3236 - 3236