Retention time prediction in temperature-programmed, comprehensive two-dimensional gas chromatography: Modeling and error assessment

被引:17
|
作者
Barcaru, Andrei [1 ]
Anroedh-Sampat, Andjoe [1 ]
Janssen, Hans-Gerd [1 ,2 ]
Vivo-Truyols, Gabriel [1 ]
机构
[1] Univ Amsterdam, Vant Hoff Inst Mol Sci, Analyt Chem Grp, NL-1098 XH Amsterdam, Netherlands
[2] Unilever Res Labs, Adv Measurements & Imaging, NL-3133 AT Vlaardingen, Netherlands
关键词
Retention time prediction; Gas chromatography; Modeling; Error assessment; K-fold cross-validation; MATHEMATICAL-MODELS; THERMODYNAMIC DATA; SOLUTE RETENTION; VISCOSITIES; INDEXES;
D O I
10.1016/j.chroma.2014.09.055
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper we present a model relating experimental factors (column lengths, diameters and thickness, modulation times, pressures and temperature programs) with retention times. Unfortunately, an analytical solution to calculate the retention in temperature programmed GCxGC is impossible, making thus necessary to perform a numerical integration. In this paper we present a computational physical model of GCxGC, capable of predicting with a high accuracy retention times in both dimensions. Once fitted (e.g., calibrated), the model is used to make predictions, which are always subject to error. In this way, the prediction can result rather in a probability distribution of (predicted) retention times than in a fixed (most likely) value. One of the most common problems that can occur when fitting unknown parameters using experimental data is overfitting. In order to detect overfitting situations and assess the error, the K-fold cross-validation technique was applied. Another technique of error assessment proposed in this article is the use of error propagation using jacobians. This method is based on estimation of the accuracy of the model by the partial derivatives of the retention time prediction with respect to the fitted parameters (in this case entropy and enthalpy for each component) in a set of given conditions. By treating the predictions of the model in terms of intervals rather than as precise values, it is possible to considerably increase the robustness of any optimization algorithm. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:190 / 198
页数:9
相关论文
共 50 条
  • [1] Separation orthogonality in temperature-programmed comprehensive two-dimensional gas chromatography
    Venkatramani, CJ
    Xu, JZ
    Phillips, JB
    ANALYTICAL CHEMISTRY, 1996, 68 (09) : 1486 - 1492
  • [2] Retention time prediction in thermally modulated comprehensive two-dimensional gas chromatography: Correcting second dimension retention time modeling error
    Jaramillo, Roman
    Dorman, Frank L.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1581 : 116 - 124
  • [3] Calculation of retention time for temperature-programmed gas chromatography
    Amasaki, I
    Gao, ZM
    Kaneko, T
    Nakada, M
    ANALYTICAL SCIENCES, 2000, 16 (11) : 1229 - 1231
  • [4] Calculation of Retention Time for Temperature-Programmed Gas Chromatography
    Iwao Amasaki
    Zhiming Gao
    Tsuyoshi Kaneko
    Masahiro Nakada
    Analytical Sciences, 2000, 16 : 1229 - 1231
  • [5] A fast temperature-programmed second-dimension column for comprehensive two-dimensional gas chromatography
    Cai, Huamin
    Stearns, Stanley D. D.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (13) : 2435 - 2446
  • [6] A fast temperature-programmed second-dimension column for comprehensive two-dimensional gas chromatography
    Huamin Cai
    Stanley D. Stearns
    Analytical and Bioanalytical Chemistry, 2023, 415 : 2435 - 2446
  • [7] Retention index in temperature-programmed gas chromatography
    Gonzalez, FR
    Nardillo, AM
    JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) : 29 - 49
  • [8] Retention modeling and retention time prediction in gas chromatography and flow-modulation comprehensive two-dimensional gas chromatography: The contribution of pressure on solute partition
    Burel, Antoine
    Vaccaro, Marie
    Cartigny, Yohann
    Tisse, Severine
    Coquerel, Gerard
    Cardinael, Pascal
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1485 : 101 - 119
  • [9] PREDICTION OF RETENTION TIMES IN TEMPERATURE-PROGRAMMED GAS SOLID AND GAS-LIQUID-CHROMATOGRAPHY
    SHROTRI, PY
    MOKASHI, A
    MUKESH, D
    JOURNAL OF CHROMATOGRAPHY, 1987, 387 : 399 - 403
  • [10] Retention time locking procedure for comprehensive two-dimensional gas chromatography
    Mommers, John
    Knooren, Jeroen
    Mengerink, Ynze
    Wilbers, Arno
    Vreuls, Rene
    van der Wal, Sjoerd
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (21) : 3159 - 3165