A corneal topographic analysis of astigmatism after excimer laser photorefractive keratectomy

被引:0
|
作者
Li, Y
Pang, GX
Jin, YM
Sun, YM
Wang, ZW
Li, WY
机构
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To identify the astigmatism changes after excimer laser photorefractive keratectomy (PRK) and the visual influence of astigmatism. Methods 109 myopic eyes followed up for more than 1 year were analyzed by videokeratography, and their visual acuities were examined, Before the operation, the astigmatic errors with cycloplegic refractive examination were -1.00 similar to-2.00 D. Results The position of astigmatism axis was basically consistent with that in corneal topography, but in astigmatism diopter there were some differences between the cycloplegic examination and topographic analysis. A stigmatism was found in 62% of the eyes, asymmetrical in 33% and against-the-rule in 5% by using topographic analysis. There was little change observed in the position of astigmatism axis after PRK observed. Some changes of postoperative astigmatism diopter were seen in different periods. It increased in the postoperative 10 days or 1 month, and afterwards gradually decreased and became stable in 6 months to 1 year. The postoperative residual astigmatism was low in degree, and did not affect the visual acuity. The actually corrected diopter was within the anticipated corrected diopter range of +/-1.00 D, accounting for 97.4%. Conclusion By using spherical equivalent method of calculation in PRK, the refractive correction of the operation in cases with myopia and low degree of astigmatism (<-2.00 D) was satisfactory.
引用
下载
收藏
页码:670 / 672
页数:3
相关论文
共 50 条
  • [1] A corneal topographic analysis of astigmatism after excimer laser photorefractive keratectomy
    李莹
    庞国祥
    金玉梅
    孙玉敏
    王造文
    李维业
    Chinese Medical Journal, 1997, (09)
  • [2] A corneal topographic analysis of astigmatism after excimer laser photorefractive keratectomy
    李莹
    庞国祥
    金玉梅
    孙玉敏
    王造文
    李维业
    中华医学杂志(英文版), 1997, (09) : 14 - 16
  • [3] Corneal topographic analysis after excimer photorefractive keratectomy
    Zhou, YH
    Li, ZH
    An, WL
    Qi, Y
    Zhang, K
    Lu, WX
    Hu, YJ
    CHINESE MEDICAL JOURNAL, 1999, 112 (03) : 214 - 216
  • [4] Corneal topographic analysis after excimer photorefractive keratectomy
    周跃华
    李志辉
    安伟丽
    齐颍
    张葵
    陆文秀
    胡雅娇
    中华医学杂志(英文版), 1999, (03) : 22 - 24
  • [5] Corneal topographic analysis after excimer photorefractive keratectomy
    周跃华
    李志辉
    安伟丽
    齐颍
    张葵
    陆文秀
    胡雅娇
    ChineseMedicalJournal, 1999, (03)
  • [6] CORNEAL TOPOGRAPHIC ANALYSIS AFTER EXCIMER PHOTOREFRACTIVE KERATECTOMY
    LIN, DTC
    OPHTHALMOLOGY, 1994, 101 (08) : 1432 - 1439
  • [7] MULTIFOCAL CORNEAL TOPOGRAPHIC CHANGES WITH EXCIMER - LASER PHOTOREFRACTIVE KERATECTOMY
    MOREIRA, H
    GARBUS, JJ
    FASANO, A
    LEE, M
    CLAPHAM, TN
    MCDONNELL, PJ
    ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (07) : 994 - 999
  • [8] Analysis of corneal topography after excimer laser photorefractive keratectomy
    Hu, FR
    Tan, CY
    Chang, SW
    Chang, HW
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 1998, 97 (03) : 159 - 164
  • [9] Surgically induced astigmatism after photorefractive keratectomy with the excimer laser
    Kapadia, MS
    Krishna, R
    Shah, S
    Wilson, SE
    CORNEA, 2000, 19 (02) : 174 - 179
  • [10] EXCIMER LASER PHOTOREFRACTIVE KERATECTOMY FOR THE TREATMENT OF ASTIGMATISM
    CHU, DF
    GIBRALTER, RP
    BELMONT, SC
    MANDELBAUM, SH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 799 - 799