Measurements of serum S-100B protein: Effects of storage time and temperature on pre-analytical stability

被引:35
|
作者
Raabe, A [1 ]
Kopetsch, O [1 ]
Gross, U [1 ]
Zimmermann, M [1 ]
Gebhart, P [1 ]
机构
[1] Univ Frankfurt, Dept Neurosurg, Neuroctr, D-60528 Frankfurt, Germany
关键词
S-100B protein; storage; pre-analytical stability;
D O I
10.1515/CCLM.2003.106
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Measurement of S-100B protein in serum or cerebrospinal fluid is increasingly used as a molecular marker of brain damage. However, there is no information about the pre-analytical in vitro stability of S-100B. We have investigated whether storing blood samples at different time periods and conditions affected the measured levels of S-100B protein. Blood samples were taken from 29 neurosurgical patients with normal serum S-100B values and from seven patients with increased serum S-100B values. Blood samples were immediately divided into nine aliquots for measuring S-100B immediately and after 4, 8, 12, and 24 hours, stored at room temperature or at 4 degreesC. Measurement of S-100B was performed using the LIAISON(R) assay (Byk-Sangtec Diagnostica, Dietzenbach, Germany). Moreover, in 10 additional patients the effect of freezing the serum and thawing the sample after 24 hours was investigated. There were no differences between the results of S-100B measurements after storing the sample at different temperatures and time periods. There was no trend towards higher or lower values in all three groups. Therefore, blood samples may be collected as part of the daily clinical routine without time constraint and even stored overnight without affecting S-100B serum levels when measured with the LIAISON(R) Sangtec(R) 100 assay.
引用
收藏
页码:700 / 703
页数:4
相关论文
共 50 条
  • [1] Effects of temperature on pre-analytical stability of S100B protein concentrations in urine of healthy full-term infants
    Gazzolo, D
    Lituania, M
    Michetti, F
    CLINICA CHIMICA ACTA, 2004, 350 (1-2) : 231 - 232
  • [2] Pre-analytical stability of the plasma proteomes based on the storage temperature
    Pasella, Sara
    Baralla, Angela
    Canu, Elisabetta
    Pinna, Sara
    Vaupel, James
    Deiana, Marta
    Franceschi, Claudio
    Baggio, Giovannella
    Zinellu, Angelo
    Sotgia, Salvatore
    Castaldo, Giuseppe
    Carru, Ciriaco
    Deiana, Luca
    PROTEOME SCIENCE, 2013, 11
  • [3] Pre-analytical stability of the plasma proteomes based on the storage temperature
    Sara Pasella
    Angela Baralla
    Elisabetta Canu
    Sara Pinna
    James Vaupel
    Marta Deiana
    Claudio Franceschi
    Giovannella Baggio
    Angelo Zinellu
    Salvatore Sotgia
    Giuseppe Castaldo
    Ciriaco Carru
    Luca Deiana
    Proteome Science, 11
  • [4] Influence of pre-analytical time and temperature conditions on serum thromboxane B2 levels
    van Diemen, J. J. K.
    Fuijkschot, W. W.
    Spit, K.
    van Reuler, A. V. R.
    Bonten, T. N.
    Numans, M. E.
    van der Bom, J. G.
    Smulders, Y. M.
    Thijs, A.
    THROMBOSIS RESEARCH, 2018, 163 : 1 - 5
  • [5] Analysis of protein S-100B in serum:: a methodological study
    Muller, Kay
    Elverland, Astrid
    Romner, Bertil
    Waterloo, Knut
    Langbakk, Bodil
    Unden, Johan
    Ingebrigtsen, Tor
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (09) : 1111 - 1114
  • [6] Serum S-100B protein in severe head injury
    Raabe, A
    Grolms, C
    Sorge, O
    Zimmermann, M
    Seifert, V
    NEUROSURGERY, 1999, 45 (03) : 477 - 483
  • [7] Serum S-100B protein in severe head injury
    Woertgen, C
    Rothoerl, RD
    NEUROSURGERY, 2000, 46 (04) : 1026 - 1027
  • [8] Serum levels of neural protein S-100B in phenylketonuria
    Schulpis, KH
    Kariyannis, C
    Papassotiriou, I
    CLINICAL BIOCHEMISTRY, 2004, 37 (01) : 76 - 79
  • [9] Serum S-100b protein as a biomarker for the assessment of neuroprotectants
    Shirasaki, Y
    Edo, N
    Sato, T
    BRAIN RESEARCH, 2004, 1021 (02) : 159 - 166
  • [10] The pre-analytical stability of 25-hydroxyvitamin D: Storage and mixing effects
    Borai, Anwar
    Khalil, Haitham
    Alghamdi, Basma
    Alhamdi, Raghad
    Ali, Najwa
    Bahijri, Suhad
    Ferns, Gordon
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2020, 34 (02)