High-Precision Ion Beam Figuring of X-Ray Plane Mirrors for the Bendable KB Focusing System

被引:7
|
作者
Zhang, Yunyang [1 ]
Huang, Qiushi [1 ]
Yan, Shuai [2 ]
Yu, Jun [1 ]
Huang, Handan [1 ]
He, Yumei [2 ]
Luo, Hongxin [2 ]
Liu, Zhi [3 ]
Zhang, Zhong [1 ]
Wang, Zhanshan [1 ]
机构
[1] Tongji Univ, Inst Precis Opt Engn IPOE, Sch Phys Sci & Engn, Key Lab Adv Microstruct Mat, Shanghai, Peoples R China
[2] Chinese Acad Sci, Shanghai Adv Res Inst, Pudong, Peoples R China
[3] ShanghaiTech Univ, Ctr Transformat Sci, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
ion beam figuring; X-Ray mirror; height error; slope error; focusing;
D O I
10.3389/fphy.2022.865411
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Two trapezoidal plane mirrors of 240 mm in length were fabricated by ion beam figuring (IBF) technology for application in a bendable KB focusing system. The correction of surface height and slope errors in different spatial frequency ranges of the mirrors was studied systematically. After one to two iterations of IBF, the figure height errors of the vertical focusing mirror (VFM) and horizontal focusing mirror (HFM) were improved from 32.4 and 65.4 nm to 2.7 and 7.2 nm (RMS), respectively. If the best-fit sphere of the surface profile was subtracted, the residual two-dimensional height errors were only 1.1 and 1.2 nm (RMS). The slope errors in the low spatial frequency range were corrected much faster than the middle frequency ones (f = similar to 1 mm(-1)), which make the low-frequency slope error much smaller. After IBF, the two-dimensional slope errors of the two mirrors calculated with a spatial interval of 1 and 10 mm were reduced to approximately 0.29 and 0.08 mu rad, respectively. Full spatial frequency characterization of the VFM before and after IBF showed that the low-frequency figure errors (f < 1 mm(-1)) were significantly reduced while the middle- and high-frequency morphologies (f > 1-2 mm(-1)) remain almost the same as before figuring. The fabricated plane mirrors were applied in the hard X-ray micro-focusing beamline in the Shanghai Synchrotron Radiation Facility (SSRF), which realized a focal spot of 2.4 mu m x 2.8 mu m at 10 keV.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Ion Beam Figuring of X-Ray Mirrors
    Schulze, Carsten
    Nestler, Matthias
    Zeuner, Michael
    ASTRONOMICAL OPTICS: DESIGN, MANUFACTURE, AND TEST OF SPACE AND GROUND SYSTEMS II, 2019, 11116
  • [2] High-precision CGH substrate figuring by ion beam
    Ma Zhan-long
    Peng Li-rong
    Wang Gao-wen
    Gu Yong-qiang
    CHINESE OPTICS, 2016, 9 (02): : 270 - 276
  • [3] Corrective capability analysis and machining error control in ion beam figuring of high-precision optical mirrors
    Liao, Wenlin
    Dai, Yifan
    Xie, Xuhui
    Zhou, Lin
    Yuan, Zheng
    OPTICAL ENGINEERING, 2012, 51 (03)
  • [4] Ion beam figuring for X-ray mirrors: history, state-of-the-art and future prospects
    Shurvinton, Riley
    Wang, Hongchang
    Pradhan, Paresh
    Nistea, Ioana-Theodora
    Alcock, Simon
    Da Silva, Murilo Bazan
    Majhi, Arindam
    Sawhney, Kawal
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 : 655 - 669
  • [5] Sub-nanometre quality X-ray mirrors created using ion beam figuring
    Majhi, Arindam
    Shurvinton, Riley
    Pradhan, Paresh Chandra
    Hand, Matthew
    Gu, Weichen
    Da Silva, Murilo Bazan
    Moriconi, Simone
    Nistea, Ioana
    Alcock, Simon G.
    Wang, Hongchang
    Sawhney, Kawal
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 : 706 - 715
  • [6] Ion Beam Figuring and Optical Metrology System for Synchrotron X-ray Optics
    Hand, Matthew
    Alcock, Simon G.
    Hillman, Michael
    Littlewood, Richard
    Moriconi, Simone
    Wang, Hongchang
    Sawhney, Kawal
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS VIII, 2019, 11109
  • [7] High-Precision X-Ray Polarimetry
    Marx, B.
    Schulze, K. S.
    Uschmann, I.
    Kaempfer, T.
    Loetzsch, R.
    Wehrhan, O.
    Wagner, W.
    Detlefs, C.
    Roth, T.
    Haertwig, J.
    Foerster, E.
    Stoehlker, T.
    Paulus, G. G.
    PHYSICAL REVIEW LETTERS, 2013, 110 (25)
  • [8] HIGH-PRECISION X-RAY METROLOGY
    SEYFRIED, P
    BECKER, P
    WINDISCH, D
    PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1988, 10 (01): : 35 - 42
  • [9] Surface evaluation of high-precision monolithic mirror for soft X-ray focusing
    Kume, T.
    Matsuzawa, Y.
    Hiraguri, K.
    Takeo, Y.
    Kimura, T.
    Kishimoto, H.
    Senba, Y.
    Ohashi, H.
    Hashizume, H.
    Mimura, H.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS XVII, 2022, 12240
  • [10] High-precision free-form optics and application to soft x-ray mirrors
    Kume, T.
    Hiraguri, K.
    Imamura, Y.
    Miyashita, H.
    Mukoda, T.
    Matsuzawa, Y.
    Takeo, Y.
    Senba, Y.
    Kishimoto, H.
    Ohashi, H.
    Mimura, H.
    Hashizume, H.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS XV, 2020, 11491