Development of a cost-effective modular SPECT/CT scanner

被引:40
|
作者
Bailey, Dale L. [1 ]
Roach, Paul J.
Bailey, Elizabeth A.
Hewlett, James
Keijzers, Ronnie
机构
[1] Royal N Shore Hosp, Dept Nucl Med, Sydney, NSW, Australia
[2] Univ Sydney, Sch Phys & Med Radiat Sci, Sydney, NSW 2006, Australia
[3] Insight Oceania, Sydney, NSW, Australia
[4] Nucl Fields Aust Pty Ltd, Sydney, NSW, Australia
关键词
tomography; emission computed; SPECT; radionuclide imaging; X-ray CT;
D O I
10.1007/s00259-006-0364-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop a combined SPECT/CT based on a conventional gamma camera with the following design goals: (i) the subject is scanned on the same bed without moving between SPECT and CT scans, (ii) maintenance of full diagnostic utility of both scanners, (iii) a minimal equipment footprint which is adaptable to different site configurations, (iv) a modular design so that either scanner can be upgraded without impacting the other scanner and (v) cost-effectiveness. Methods A Philips SKYLight gamma camera was combined with a single-slice helical CT. The CT bed has been modified by mounting on wheels and is attached to a track in the floor when required. The CT bed is used for both the CT and the SPECT scans. The CT bed is parked outside the SKYLight's active area when not required. The CT data are used for anatomical localisation, attenuation correction and definition of anatomical boundaries (e.g. lobar boundaries in the lungs). Results The combined SPECT/CT system is installed in a 6.2 m x 4.6 m room. The CT can scan up to 1.3 m of the subject, which is usually sufficient for registration with the SPECT scan. More than 200 subjects have had SPECT/CT scans in the first year of operation. Initially, the main outcome has been improved confidence of localisation of abnormalities. Attenuation correction for all relevant radionuclides has been implemented. Conclusion We have developed a combined SPECT/CT using a novel approach based on a low-cost CT scanner. The design is compact, is readily upgradeable and does not compromise either machine's diagnostic or functional capabilities.
引用
收藏
页码:1415 / 1426
页数:12
相关论文
共 50 条
  • [1] Development of a cost-effective modular SPECT/CT scanner
    Dale L. Bailey
    Paul J. Roach
    Elizabeth A. Bailey
    James Hewlett
    Ronnie Keijzers
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 1415 - 1426
  • [2] Development and preliminary results of Xtrim-PET, a modular cost-effective preclinical scanner
    Sajedi, Salar
    Zeraatkar, Navid
    Taheri, Mohsen
    Kaviani, Sanaz
    Khanmohammadi, Hadi
    Sarkar, Saeed
    Sabet, Hamid
    Ay, Mohammad Reza
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 940 : 288 - 295
  • [3] Development of a Cost-Effective Modular Pixelated NaI(Tl) Detector for Clinical SPECT Applications
    Rozler, Mike
    Liang, Haoning
    Chang, Wei
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1831 - 1840
  • [4] Modular drive is cost-effective
    不详
    PROFESSIONAL ENGINEERING, 2005, 18 (17) : 43 - 43
  • [5] A Cost-Effective Modular Phased Array
    Mayo, Richard
    Harmer, Stuart
    2013 IEEE INTERNATIONAL SYMPOSIUM ON PHASED ARRAY SYSTEMS AND TECHNOLOGY, 2013, : 93 - 96
  • [6] A Modular Car Body for Sustainable, Cost-Effective, and Versatile Vehicle Development
    Hartmann, Christoph
    Welm, Markus
    Schreyer, Sven
    Hartmann, Christoph
    Volk, Wolfram
    TECHNOLOGIES, 2021, 9 (01)
  • [7] Development and performance evaluation of cost-effective micro-CT
    Heo, Sung Kyn
    Yun, Seung Man
    Cho, Min Kook
    Kim, Ho Kyung
    Graeve, Thorsten
    Cho, Hyosung
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3729 - +
  • [8] Modular and Cost-Effective Computed Tomography Design
    Bieberle, Andre
    Hoffmann, Rainer
    Doess, Alexander
    Schleicher, Eckhard
    Hampel, Uwe
    SENSORS, 2024, 24 (08)
  • [9] A Cost-effective Approach to evaluating Security Vulnerability Scanner
    Tung, Yuan-Hsin
    Tseng, Shian-Shyong
    Shih, Jen-Feng
    Shan, Hwai-Ling
    2013 15TH ASIA-PACIFIC NETWORK OPERATIONS AND MANAGEMENT SYMPOSIUM (APNOMS), 2013,
  • [10] Cost-effective laboratory development
    Farach, JM
    AMERICAN LABORATORY, 2004, 36 (02) : 20 - +