Ion mobility mass spectrometry of in situ generated biomass pyrolysis products

被引:5
|
作者
Castilla, Clement [1 ]
Ruger, Christopher P. [1 ,2 ,3 ]
Lavanant, Helene [1 ]
Afonso, Carlos [1 ,3 ]
机构
[1] Normandie Univ, CNRS, INSA Rouen, UNIROUEN,COBRA, F-76000 Rouen, France
[2] Univ Rostock, Abt Analyt & Tech Chem, Inst Chem, Dr Lorenz Weg 2, DE-18059 Rostock, Germany
[3] Int Joint Lab iC2MC Complex Matrices Mol Characte, TRTG, BP 27, F-76700 Harfleur, France
关键词
Ambient ionization; Lignocellulosic biomass; Ion mobility; Ultra high resolution mass spectrometry; Biomass pellets; Multivariate data analysis; ATMOSPHERIC SOLIDS ANALYSIS; CHEMICAL-COMPOSITION; CURIE-POINT; GAS; LIGNIN; IDENTIFICATION; IONIZATION; CONVERSION; PRESSURE; MATTER;
D O I
10.1016/j.jaap.2021.105164
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lignocellulosic biomass is an abundant and renewable energy source that can be used as biofuel after physicochemical conversion, e.g. by fast pyrolysis. However, the chemical variations from wood and other biomass species affect this conversion. Chemical characterization is needed to obtain more information on the pyrolysis products depending on the biomass type and pyrolysis conditions. Here, we compared the fast pyrolysis molecular pattern of five lignocellulosic biomasses (beech, hickory, miscanthus and two brands of resinous wood pellets) obtained from a direct analysis method of solid samples coupled to ion mobility and time of flight mass spectrometry (IM-TOF MS). Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) with its ultra-high resolving power was used, with a similar solid analysis introduction approach, to probe for the presence of possible unresolved isobaric compounds in the IM-TOF MS analysis. Isobaric interferences were found to be negligible and molecular formulas determined using IM-TOF MS were confirmed as reliable. Principal component analysis on the molecular formulas allowed the extraction of marker ions preferentially found in hardwood and miscanthus or softwood species. Ion mobility drift time values from these biomass markers were converted into collision-cross sections (CCS), a direct measure of structure and shape of a molecule. No significant CCS differences were observed between the markers of the five wood samples, showing isomeric similarities between the samples. In order to move forward on the structural elucidation and characterization of the pyrolysis products, IM-TOF MS and tandem mass spectrometry (MS/MS) were performed on standard molecules and compared to the biomass pyrolysis products, highlighting the presence of isomers in the wood pyrolysis products.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] In situ analysis of intact proteins by ion mobility mass spectrometry
    Sisley, Emma K.
    Illes-Toth, Eva
    Cooper, Helen J.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 124
  • [2] Real-time analysis of pyrolysis products by ambient ionization combined with ion mobility and tandem mass spectrometry
    Spencer, Sandra E.
    Isenberg, Samantha L.
    Le, Molly
    Glish, Gary L.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [3] Ion Mobility Mass Spectrometry
    Barran, Perdita
    Ruotolo, Brandon
    ANALYST, 2015, 14 (20) : 6772 - 6774
  • [4] Fast Online Separation and Identification of Electrochemically Generated Isomeric Oxidation Products by Trapped Ion Mobility-Mass Spectrometry
    Fangmeyer, Jens
    Scheeren, Simon G.
    Schmid, Robin
    Karst, Uwe
    ANALYTICAL CHEMISTRY, 2020, 92 (01) : 1205 - 1210
  • [5] Investigating the Potential of Ion Mobility-Mass Spectrometry for Microalgae Biomass Characterization
    Fasciotti, Maira
    Souza, Gustavo H. M. F.
    Astarita, Giuseppe
    Costa, Ingrid C. R.
    Monteiro, Thays. V. C.
    Teixeira, Claudia M. L. L.
    Eberlin, Marcos N.
    Sarpal, Amarijt S.
    ANALYTICAL CHEMISTRY, 2019, 91 (14) : 9266 - 9276
  • [6] Thermogravimetry and mass spectrometry study on pyrolysis of biomass
    Stolarek, Pawel
    Ledakowicz, Stanislaw
    PRZEMYSL CHEMICZNY, 2006, 85 (8-9): : 1154 - 1156
  • [7] Developments in ion mobility spectrometry–mass spectrometry
    D. Collins
    M. Lee
    Analytical and Bioanalytical Chemistry, 2002, 372 : 66 - 73
  • [8] Coupling trapped ion mobility spectrometry to mass spectrometry: trapped ion mobility spectrometry-time-of-flight mass spectrometry versus trapped ion mobility spectrometry-Fourier transform ion cyclotron resonance mass spectrometry
    Tose, Lilian V.
    Benigni, Paolo
    Leyva, Dennys
    Sundberg, Abigail
    Ramirez, Cesar E.
    Ridgeway, Mark E.
    Park, Melvin A.
    Romao, Wanderson
    Jaffe, Rudolf
    Fernandez-Lima, Francisco
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (15) : 1287 - 1295
  • [9] ION MOBILITY SPECTROMETRY AND ION MOBILITY SPECTROMETRY MASS-SPECTROMETRIC CHARACTERIZATION OF DIMENHYDRINATE
    LAWRENCE, AH
    NANJII, AA
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12): : 345 - 347
  • [10] Ion mobility-mass spectrometry
    Kanu, Abu B.
    Dwivedi, Prabha
    Tam, Maggie
    Matz, Laura
    Hill, Herbert H., Jr.
    JOURNAL OF MASS SPECTROMETRY, 2008, 43 (01): : 1 - 22