Animal experimental studies using small intestine endoscope

被引:1
|
作者
Liu, Jin-Hua [1 ]
Liu, Dan-Yang [2 ]
Wang, Li [1 ]
Han, Li-Ping [3 ]
Qi, Zhe-Yu [1 ]
Ren, Hai-Jun [1 ]
Feng, Yan [1 ]
Luan, Feng-Ming [1 ]
Mi, Liang-Tian [1 ]
Shan, Shu-Mei [4 ]
机构
[1] Dalian Med Univ, Affiliated Dalian Municipal Friendship Hosp, Dept Gen Surg, Dalian 116001, Liaoning Provin, Peoples R China
[2] Dalian Med Univ, Affiliated Dalian Municipal Friendship Hosp, Dept Endocrinol, 8 Sanba Sq, Dalian 116001, Liaoning Provin, Peoples R China
[3] Dalian Med Univ, Affiliated Dalian Municipal Friendship Hosp, Dept Anesthesiol, Dalian 116001, Liaoning Provin, Peoples R China
[4] Dalian Ming Sheng Technol Dev Co Ltd, Dalian 116001, Liaoning Provin, Peoples R China
关键词
Small intestine endoscope; Endoscope; Animal experiment; Endoscopic examination; Negative-pressure suction; DOUBLE-BALLOON ENDOSCOPY; LONG-TERM OUTCOMES; CAPSULE ENDOSCOPY; MULTICENTER; ENTEROSCOPY; METAANALYSIS; DISEASE; JAPAN;
D O I
10.3748/wjg.v23.i20.3684
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM To assess the feasibility and safety of a novel enteroscope, negative-pressure suction endoscope in examining the small intestine of a porcine model. METHODS In vitro experiments in small intestinal loops from 20 pigs and in vivo experiments in 20 living pigs were conducted. RESULTS In in vitro experiments, a negative pressure of > 0.06 MPa was necessary for optimal visualization of the intestine, and this pressure did not cause gross or histological damage to the mucosa. For satisfactory examination of the small intestine in vivo, higher negative pressure (> 1.00 MPa) was required. Despite this higher pressure, the small intestine did not show any gross or microscopic damage in the suctioned areas. The average time of examination in the living animals was 60 +/- 7.67 min. The animals did not experience any apparent ill effects from the procedure. CONCLUSION Small intestine endoscope was safely performed within a reasonable time period and enabled complete visualization of the intestine in most cases.
引用
收藏
页码:3684 / 3689
页数:6
相关论文
共 50 条
  • [1] Animal experimental studies using small intestine endoscope
    Jin-Hua Liu
    Dan-Yang Liu
    Li Wang
    Li-Ping Han
    Zhe-Yu Qi
    Hai-Jun Ren
    Yan Feng
    Feng-Ming Luan
    Liang-Tian Mi
    Shu-Mei Shan
    World Journal of Gastroenterology, 2017, (20) : 3684 - 3689
  • [2] An experimental study of resistant properties of the small intestine for an active capsule endoscope
    Wang, X.
    Meng, M. Q-H
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H1) : 107 - 118
  • [3] DUMPING AND SMALL-INTESTINE - EXPERIMENTAL STUDIES
    AMDRUP, E
    AMDRUP, BM
    BIOLOGIE ET GASTRO-ENTEROLOGIE, 1972, 5 (02): : C510 - &
  • [4] Measurement of gastric and small intestine transit time using the video capsule endoscope
    Balba, NH
    Chutkan, RK
    GASTROINTESTINAL ENDOSCOPY, 2002, 55 (05) : AB136 - AB136
  • [5] Suction Parameters for the Development of a Robotic Endoscope for Traversing the Small Intestine
    Montane, Roberto
    Kowalczyk, Lukasz M.
    Gupte, Anand
    Crane, Carl D.
    Wagh, Mihir S.
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) : AB107 - AB107
  • [6] ANALYSIS OF PROPULSIVE MOVEMENTS OF SMALL-INTESTINE - CINERADIOGRAPHIC AND EXPERIMENTAL STUDIES
    LENZ, H
    BLOMER, A
    DUX, A
    AMERICAN JOURNAL OF DIGESTIVE DISEASES, 1971, 16 (12): : 1107 - +
  • [7] Effects of an Inserted Endoscope on Chyme Movement in Small Intestine - A Theoretical Model
    Srivastava, V. P.
    APPLICATIONS AND APPLIED MATHEMATICS-AN INTERNATIONAL JOURNAL, 2007, 2 (02): : 79 - 91
  • [8] DEEP TRANSFORMERS FOR FAST SMALL INTESTINE GROUNDING IN CAPSULE ENDOSCOPE VIDEO
    Zhao, Xinkai
    Fang, Chaowei
    Gao, Feng
    Fan, De-Jun
    Lin, Xutao
    Li, Guanbin
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 150 - 154
  • [9] Epidermal Cell Sheet Transplantation on an Anastomotic Site of the Small Intestine in an Experimental Animal Model
    Bamba, Yoshiko
    Kanai, Nobuo
    Kobayashi, Shinichiro
    Shindo, Hironari
    Kameoka, Shingo
    Yamamoto, Masakazu
    INTERNATIONAL SURGERY, 2018, 103 (11-12) : 552 - 560
  • [10] Study of frictional properties of the small intestine for design of active capsule endoscope
    Wang, Xiaona
    Meng, Max Q. -H.
    2006 1ST IEEE RAS-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS, VOLS 1-3, 2006, : 983 - +