Characterization of compression behaviors of Acupoint Catgut-embedding monofilaments for the human body: A test method of monofilaments by the three-point bending model

被引:2
|
作者
Fu, Shao-ju [1 ,2 ]
Zhang, Pei-hua [1 ,2 ]
机构
[1] Donghua Univ, Coll Text, Shanghai, Peoples R China
[2] Minist Educ, Key Lab Text Sci & Technol, Beijing, Peoples R China
关键词
acupoint Catgut-embedding therapy; compression behaviors; three-point bending model; winding laps; compression platens; FIBERS; RISK;
D O I
10.1177/0040517517708540
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
Acupoint Catgut-embedding therapy (ACET) is considered an advanced method for the treatment of juvenile pseudomyopia. However, the existing test methods of ACE monofilaments cannot meet the desire for accurate measurement and convenient operation. This paper presents a study of the compression behaviors of ACE monofilaments developed for the human body. To investigate a convenient and accurate test method for monofilaments, different materials, including polypropylene (PP), polylactic acid (PLA) and polyglycolide acid (PGA), were designed to a curved rod shape based on the three-point bending model used in this work. Variables, including the number of winding laps, the diameter of the compression platens and the compression rate of specimens, were discussed by the platform compression method. Properties such as radial force, the compression modulus and recovery ratio were also tested and analyzed. The results revealed that the winding lap of 25r was selected as the most suitable number according to the principles of stability and accuracy. The diameter of the compression platen should be larger than the outer diameter of the specimens, due to which the diameter of 5mm was less than expected in this work. Meanwhile, the average value of the maximum radial force (F) was PP (98.35 cN)>PLA-1 (84.67 cN)>PGA (63.68 cN)>PLA-2 (39.24 cN)>PLA-3 (20.15 cN). The compression rate of 50% should be selected as the optimum parameter. In conclusion, this test method of monofilaments was successfully developed and has a potential application for the characterization of compression behaviors of ACE monofilaments for the human body.
引用
收藏
页码:1755 / 1765
页数:11
相关论文
共 3 条
  • [1] Surface modification of polylactic acid (PLA) and polyglycolic acid (PGA) monofilaments via the cold plasma method for acupoint catgut-embedding therapy applications
    Fu, Shaoju
    Zhang, Peihua
    TEXTILE RESEARCH JOURNAL, 2019, 89 (18) : 3839 - 3849
  • [2] Importance of asymmetry and anisotropy in predicting cortical bone response and fracture using human body model femur in three-point bending and axial rotation
    Khor, F.
    Cronin, D. S.
    Watson, B.
    Gierczycka, D.
    Malcolm, S.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 87 : 213 - 229
  • [3] Verification of Numerical Model for Trabecular Tissue using Compression Test and Time-Lapse X-Ray Radiography based on Material Model Determined from Three-Point Bending Test of Single Trabecula
    Zlamal, Petr
    Doktor, Tomas
    Jirousek, Ondrej
    Jandejsek, Ivan
    LOCAL MECHANICAL PROPERTIES IX, 2014, 586 : 265 - +