2-dimensional shear wave elastography: Interobserver agreement and factors related to interobserver discrepancy

被引:12
|
作者
Yoon, Kibo [1 ]
Jeong, Woo Kyoung [2 ,3 ]
Kim, Yongsoo [1 ]
Kim, Min Yeong [2 ,3 ]
Kim, Tae Yeob [4 ]
Sohn, Joo Hyun [4 ]
机构
[1] Hanyang Univ, Hanyang Univ Gun Hosp, Dept Radiol, Guri, Gyeonggi, South Korea
[2] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Dept Radiol, Seoul, South Korea
[3] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Ctr Imaging Sci, Seoul, South Korea
[4] Hanyang Univ, Hanyang Univ Gun Hosp, Coll Med, Dept Internal Med, Guri, Gyeonggi, South Korea
来源
PLOS ONE | 2017年 / 12卷 / 04期
关键词
LIVER FIBROSIS; TRANSIENT ELASTOGRAPHY; RHEUMATOID-ARTHRITIS; HEPATITIS-C; STIFFNESS; RELIABILITY; REPRODUCIBILITY; ELASTICITY; ACCURACY; ARFI;
D O I
10.1371/journal.pone.0175747
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To evaluate the interobserver reproducibility of two-dimensional shear wave elastography (2D-SWE) in measuring liver stiffness (LS) and to investigate factors related to liver 2D-SWE. Materials and methods A prospective study was conducted between August 2011 and August 2012 in rheumatoid arthritis patients who had been treated with methotrexate. Interobserver reproducibility of 2D-SWE was evaluated, and the relationship between interobserver difference in LS and related factors was analyzed using linear regression analyses. We considered age, sex, alanine transaminase, cholesterol, body mass index (BMI), and waist circumference as clinical factors, and the mean value of standard deviation (SDM), its difference between two examiners, mean diameter of the regions of interest (ROIM), and its difference in the elasticity map as investigation factors. The cut-off value for significant factors to predict interobserver discrepancies in LS-based fibrosis stage was also inspected. Results In total, 176 patients were enrolled. The intraclass correlation coefficient between the two examiners was 0.784. In the univariate analysis, SDM and ROIM were independently associated with interobserver differences in LS as well as BMI, waist circumference, and the difference of ROI, but SDM and ROIM were the only ones significantly related in multivariate analysis (p<0.001 and p = 0.021, respectively). The best cut-off value for SDM in predicting interobserver discrepancy in LS-based fibrosis stage was 1.4. Conclusions Interobserver reproducibility of 2D-SWE for measuring LS was good and SDM was the most significantly associated factor with interobserver differences in LS and interobserver discordance in LS-based fibrosis stage.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Two-Dimensional Shear Wave Elastography of Normal Soft Tissue Organs in Adult Beagle Dogs; Interobserver Agreement and Sources of Variability
    Jung, Jin-Woo
    Je, Hyejin
    Lee, Sang-Kwon
    Jang, Youjung
    Choi, Jihye
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8
  • [2] Interobserver discrepancy in liver fibrosis using transient elastography
    Roca, B.
    Resino, E.
    Torres, V.
    Herrero, E.
    Penades, M.
    JOURNAL OF VIRAL HEPATITIS, 2012, 19 (10) : 711 - 715
  • [3] Intra- and Interobserver Variability of Shear Wave Elastography in Rectal Cancer
    Loft, Martina Kastrup
    Pedersen, Malene Roland Vils
    Grimm, Peter
    Lauritzen, Andreas Hoffmann
    Dam, Claus
    Rafaelsen, Soren Rafael
    CANCERS, 2022, 14 (11)
  • [4] Reliability Indicators for 2-Dimensional Shear Wave Elastography
    O'Hara, Sandra
    Zelesco, Marilyn
    Rocke, Karen
    Stevenson, Gil
    Sun, Zhonghua
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (11) : 3065 - 3071
  • [5] Interobserver Agreement and Intraobserver Reproducibility in Thyroid Ultrasound Elastography
    Lim, Dong-Jun
    Luo, Si
    Kim, Min-Hee
    Ko, Sun-Hee
    Kim, Yongmin
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (04) : 896 - 901
  • [6] Interobserver Agreement for Thyroid Elastography Value of the Quality Factor
    Cepero Calvete, Angela
    Manuel Rodriguez, J.
    de Dios Berna-Mestre, Juan
    Rios, Antonio
    Abellan-Rivero, Delores
    Reus, Manuel
    JOURNAL OF ULTRASOUND IN MEDICINE, 2013, 32 (03) : 495 - 504
  • [7] Intra- and Interobserver Reliability of Shear Wave Elastography in Breast Cancer Diagnosis
    Togawa, Riku
    Pfob, Andre
    Buesch, Christopher
    Fastner, Sarah
    Gomez, Christina
    Goncalo, Manuela
    Hennigs, Andre
    Killinger, Kristina
    Nees, Juliane
    Riedel, Fabian
    Schaefgen, Benedikt
    Stieber, Anne
    Tozaki, Mitsuhiro
    Heil, Joerg
    Barr, Richard
    Golatta, Michael
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (01) : 109 - 114
  • [8] Reproducibility of 2-Dimensional Shear Wave Elastography Assessment of the Liver
    Fang, Cheng
    Konstantatou, Eleni
    Romanos, Odyssefs
    Yusuf, Gibran T.
    Quinlan, Daniel J.
    Sidhu, Paul S.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (08) : 1563 - 1569
  • [9] Interobserver agreement of EUS elastography in the evaluation of solid pancreatic lesions
    Soares, Joao-Bruno
    Iglesias-Garcia, Julio
    Goncalves, Bruno
    Lindkvist, Bjorn
    Larino-Noia, Jose
    Bastos, Pedro
    Caetano, Ana Celia
    Ferreira, Anibal
    Pimentel-Nunes, Pedro
    Lopes, Luis
    Moutinho-Ribeiro, Pedro
    Enrique Dominguez-Munoz, J.
    ENDOSCOPIC ULTRASOUND, 2015, 4 (03) : 244 - 249
  • [10] Agreement Between 2-Dimensional Shear Wave and Transient Elastography Values for Diagnosis of Advanced Chronic Liver Disease
    Cassinotto, Christophe
    Guiu, Boris
    des Grottes, Hortense Marraud
    Piron, Lauranne
    Merrouche, Wassil
    Irles-Depe, Marie
    Molinari, Nicolas
    Lapuyade, Bruno
    Ledinghen, Victor De
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2020, 18 (13) : 2971 - +