Motion compensation in extremity cone-beam computed tomography

被引:14
|
作者
Sisniega, Alejandro [1 ]
Thawait, Gaurav K. [1 ,2 ]
Shakoor, Delaram [2 ]
Siewerdsen, Jeffrey H. [1 ,2 ]
Demehri, Shadpour [2 ]
Zbijewski, Wojciech [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Russel H Morgan Dept Radiol, Baltimore, MD 21278 USA
关键词
Motion compensation; Extremity cone-beam CT; Visual grading characteristic; Weight-bearing; IMAGE QUALITY; WEIGHT-BEARING; SOFT-TISSUE; CT; EXPERIENCE; FOOT;
D O I
10.1007/s00256-019-03241-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives To evaluate the improvement in extremity cone-beam computed tomography (CBCT) image quality in datasets with motion artifact using a motion compensation method based on maximizing image sharpness. Methods Following IRB approval, retrospective analysis of 308 CBCT scans of lower extremities was performed by a fellowship-trained musculoskeletal radiologist to identify images with moderate to severe motion artifact. Twenty-four scans of 22 patients (18 male, four female; mean, 32 years old, range, 21-74 years old) were chosen for inclusion. Sharp (bone) and smooth (soft tissue) reconstructions were processed using the motion compensation algorithm. Two experts rated visualization of trabecular bone, cortical bone, joint spaces, and tendon on a nine-level Likert scale with and without motion compensation (a total of 96 datasets). Visual grading characteristics (VGC) was used to quantitatively determine the difference in image quality following motion compensation. Intra-class correlation coefficient (ICC) was obtained to assess inter-observer agreement. Results Motion-compensated images exhibited appreciable reduction in artifacts. The observer study demonstrated the associated improvement in diagnostic quality. The fraction of cases receiving scores better than "Fair" increased from less than 10% without compensation to 40-70% following compensation, depending on the task. The area under the VGC curve was 0.75 (tendon) to 0.85 (cortical bone), confirming preference for motion compensated images. ICC values showed excellent agreement between readers before (ICC range, 0.8-0.91) and after motion compensation (ICC range, 0.92-0.97). Conclusions The motion compensation algorithm significantly improved the visualization of bone and soft tissue structures in extremity CBCT for cases exhibiting patient motion.
引用
收藏
页码:1999 / 2007
页数:9
相关论文
共 50 条
  • [1] Motion compensation in extremity cone-beam computed tomography
    Alejandro Sisniega
    Gaurav K. Thawait
    Delaram Shakoor
    Jeffrey H. Siewerdsen
    Shadpour Demehri
    Wojciech Zbijewski
    [J]. Skeletal Radiology, 2019, 48 : 1999 - 2007
  • [2] AUTOMATIC MOTION CORRECTION IN CONE-BEAM COMPUTED TOMOGRAPHY
    Ens, S.
    Ulrici, J.
    Hell, E.
    Buzug, T. M.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3248 - 3251
  • [3] Motion Correction Algorithm for Cone-Beam Computed Tomography
    Lee, Jiyoung
    Kim, Jinwoo
    Cho, Minkook
    [J]. MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [4] Comparison of Cone-Beam Computed Tomography and Multislice Computed Tomography in the Assessment of Extremity Fractures
    Dubreuil, Thibaut
    Mouly, Jerome
    Ltaief-Boudrigua, Aicha
    Martinon, Amanda
    Tilhet-Coartet, Stephane
    Tazarourte, Karim
    Pialat, Jean-Baptiste
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 372 - 378
  • [5] AUTOMATIC DETECTION OF PATIENT MOTION IN CONE-BEAM COMPUTED TOMOGRAPHY
    Ens, S.
    Ulrici, J.
    Hell, E.
    Buzug, T. M.
    [J]. 2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1257 - 1260
  • [6] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    [J]. JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [7] Joint Motion Estimation and Compensation for Four-Dimensional Cone-Beam Computed Tomography Image Reconstruction
    Mo, Ying
    Liu, Jia
    Li, Qian
    Yu, Jiahong
    Zhang, Kunpeng
    Gao, Yang
    Zhang, Hua
    [J]. IEEE ACCESS, 2021, 9 : 147559 - 147569
  • [8] 4D cone-beam computed tomography combining total variation regularization and motion compensation
    Mory, C.
    Rit, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S68 - S69
  • [9] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    [J]. DENTISTRY JOURNAL, 2019, 7 (03)
  • [10] Detecting Patient Motion in Projection Space for Cone-beam Computed Tomography
    Wein, Wolfgang
    Ladikos, Alexander
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 516 - 523