Stability of lyophilized pooled sera as quality control materials for tumor marker assays in external quality assessment

被引:2
|
作者
Ahn, Sunyoung [1 ]
Park, Jungyong [1 ]
Kim, Young Ran [1 ]
Kim, Jeong-Ho [1 ]
Kim, Hyon-Suk [1 ]
机构
[1] Yonsei Univ, Coll Med, Severance Hosp, Dept Lab Med, Seoul, South Korea
关键词
Lyophilization; Tumor marker; Stability; Quality control; External quality assessment;
D O I
10.1016/j.cca.2017.05.035
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: External quality assessment(EQA) requires stable quality control (QC) materials. We evaluated the stability of QC materials made of lyophilized and liquid pooled sera for the tumor markers a-fetoprotein, carcinoembryonic antigen, carbohydrate antigen 125, and carbohydrate antigen 19-9. Methods: Specimens of the 4 tumor markers were collected from the sera of patients and stored at -20 degrees C. After sera collection and pooling, liquid or lyophilized samples were stored at -20 degrees C, 5 degrees C, or room temperature. Tumor markers were quantified on days 0, 1, 4, 7, 14, 30, and 90 of storage. Internal QC results were analyzed, and the effects of heat inactivation and sucrose addition were assessed. Results: Heat inactivation lowered tumor marker levels in lyophilized pooled sera, whereas sucrose addition had no effect. The coefficients of variation of the internal QC results were stable, whereas those of lyophilized samples were higher than those of liquid samples. Tumor marker levels were significantly lower in lyophilized samples (p < 0.05) and did not significantly differ according to storage temperature. A declining trend over time was observed for all tumor markers. Conclusions: Lyophilized QC materials are insufficiently
引用
收藏
页码:233 / 242
页数:10
相关论文
共 50 条
  • [1] STABILITY OF GLUCOSE IN LYOPHILIZED QUALITY-CONTROL SERA
    MCSWEENEY, FM
    [J]. ANNALES DE BIOLOGIE CLINIQUE, 1978, 36 (03) : 301 - 302
  • [2] Overview:: Quality control of tumor marker assays
    Kruse, R
    Geilenkeuser, MJ
    Röhle, G
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 1998, 13 (04): : 238 - 240
  • [3] BEHAVIOR OF FROZEN SERUM POOLS AND LYOPHILIZED SERA IN AN EXTERNAL QUALITY-ASSESSMENT SCHEME
    FERRERO, CA
    CAROBENE, A
    CERIOTTI, F
    MODENESE, A
    ARCELLONI, C
    [J]. CLINICAL CHEMISTRY, 1995, 41 (04) : 575 - 580
  • [4] TESTING THE ACCURACY OF TOTAL CHOLESTEROL ASSAYS IN AN EXTERNAL QUALITY-CONTROL PROGRAM - EFFECT OF ADDING SUCROSE TO LYOPHILIZED CONTROL SERA COMPARED WITH USE OF FRESH OR FROZEN SERA
    BAADENHUIJSEN, H
    DEMACKER, PNM
    HESSELS, M
    BOERMA, GJM
    PENDERS, TJ
    WEYKAMP, C
    WILLEMS, HL
    [J]. CLINICAL CHEMISTRY, 1995, 41 (05) : 724 - 730
  • [5] STANDARDIZATION AND QUALITY-CONTROL OF TUMOR-MARKER ASSAYS
    WARD, AM
    [J]. DISEASE MARKERS, 1991, 9 (3-4) : 127 - 132
  • [6] THE EXTERNAL QUALITY ASSESSMENT OF HORMONE ASSAYS
    SETH, J
    [J]. JOURNAL OF CLINICAL BIOCHEMISTRY AND NUTRITION, 1987, 2 (02) : 111 - 139
  • [7] Homogeneity and Stability Evaluation of External Quality Assessment Control Materials for Four Coagulation Tests
    Yuan, Huimin
    Gao, Zhiqi
    Zhang, Jianping
    Yue, Yuhong
    Zhang, Shunli
    Zhang, Rui
    [J]. CLINICAL LABORATORY, 2021, 67 (05) : 1221 - 1227
  • [8] EXTERNAL QUALITY ASSESSMENT OF SERUM ALPHAFETOPROTEIN ASSAYS
    POLANSKA, AI
    ORR, H
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1982, 19 (JUL) : 252 - 252
  • [9] EXTERNAL QUALITY ASSESSMENT OF ASSAYS OF LEAD IN BLOOD
    BULLOCK, DG
    SMITH, NJ
    WHITEHEAD, TP
    [J]. CLINICAL CHEMISTRY, 1986, 32 (10) : 1884 - 1889
  • [10] BACTERIOLOGIC SURVEY OF LYOPHILIZED CHEMICAL QUALITY CONTROL MATERIALS
    BEELER, MF
    SAMUELS, MS
    CARRERA, AE
    HOOD, MW
    DICKINSON, CS
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1971, 56 (06) : 676 - +