Automated catheter tip repositioning for intra-cardiac echocardiography

被引:3
|
作者
Kim, Young-Ho [1 ]
Collins, Jarrod [1 ]
Li, Zhongyu [2 ]
Chinnadurai, Ponraj [3 ]
Kapoor, Ankur [1 ]
Lin, C. Huie [2 ,4 ]
Mansi, Tommaso [1 ]
机构
[1] Siemens Healthineers, Digital Technol & Innovat, Princeton, NJ 08540 USA
[2] Houston Methodist Res Inst, Houston, TX USA
[3] Siemens Med Solut Inc, Adv Therapies, Malvern, PA USA
[4] Houston Methodist DeBakey Heart & Vasc Ctr, Houston, TX USA
关键词
Automated view recovery; Path planning; Intra-cardiac echocardiography (ICE); Catheter; Tendon-driven manipulator; Cardiac imaging; ATRIAL; ABLATION; GUIDANCE;
D O I
10.1007/s11548-022-02631-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Intra-Cardiac Echocardiography (ICE) is a powerful imaging modality for guiding cardiac electrophysiology and structural heart interventions. ICE provides real-time observation of anatomy and devices, while enabling direct monitoring of potential complications. In single operator settings, the physician needs to switch back-and-forth between the ICE catheter and therapy device, making continuous ICE support impossible. Two operator setups are sometimes implemented, but increase procedural costs and room occupation. Methods ICE catheter robotic control system is developed with automated catheter tip repositioning (i.e., view recovery) method, which can reproduce important views previously navigated to and saved by the user. The performance of the proposed method is demonstrated and evaluated in a combination of heart phantom and animal experiments. Results Automated ICE view recovery achieved catheter tip position accuracy of 2.09 +/- 0.90 mm and catheter image orientation accuracy of 3.93 +/- 2.07 degrees in animal studies, and 0.67 +/- 0.79 mm and 0.37 +/- 0.19 degrees in heart phantom studies, respectively. Our proposed method is also successfully used during transseptal puncture in animals without complications, showing the possibility for fluoro-less transseptal puncture with ICE catheter robot. Conclusion Robotic ICE imaging has the potential to provide precise and reproducible anatomical views, which can reduce overall execution time, labor burden of procedures, and X-ray usage for a range of cardiac procedures.
引用
收藏
页码:1409 / 1417
页数:9
相关论文
共 50 条
  • [1] Automated catheter tip repositioning for intra-cardiac echocardiography
    Young-Ho Kim
    Jarrod Collins
    Zhongyu Li
    Ponraj Chinnadurai
    Ankur Kapoor
    C. Huie Lin
    Tommaso Mansi
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1409 - 1417
  • [2] TRANSVENOUS INTRA-CARDIAC ECHOCARDIOGRAPHY
    GLASSMAN, E
    KRONZON, I
    [J]. CIRCULATION, 1979, 60 (04) : 203 - 203
  • [3] Validation Study of Intra-Cardiac Echocardiography in Trans-Catheter Closure of Patent Ductus Arteriosus
    Yoshimoto, Hironaga
    Suda, Kenji
    Maeda, Yasuto
    Kagiyama, Hiroyuki
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (13) : B759 - B759
  • [4] SENSITIVITY OF CONTRAST ECHOCARDIOGRAPHY IN DETECTING INTRA-CARDIAC SHUNTS
    PIERONI, DR
    VARGHESE, PJ
    FREEDOM, RM
    ROWE, RD
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1979, 5 (01): : 19 - 29
  • [5] Characterisation of intra-cardiac masses by myocardial contrast echocardiography
    Bhattacharyya, Sanjeev
    Khattar, Rajdeep
    Senior, Roxy
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 (01) : E11 - E13
  • [6] INTRA-CARDIAC PHONOCARDIOGRAPHY - INTRA-CARDIAC SOUND AND PRESSURE IN MAN
    WOOLEY, CF
    [J]. CIRCULATION, 1978, 57 (06) : 1039 - 1054
  • [7] CONTRIBUTION OF TM ECHOCARDIOGRAPHY IN INTRA-CARDIAC TUMOR-DETECTION
    TRICOT, R
    VALERE, PE
    HOUEIX, JM
    LAFAY, N
    LEHNER, MJP
    [J]. SEMAINE DES HOPITAUX, 1979, 55 (43-4): : 2065 - 2065
  • [8] Intra-cardiac echocardiography guided catheter ablation of a right posterior accessory pathway in a patient with Ebstein's anomaly
    Shimane, Akira
    Okajima, Katsunori
    Kiuchi, Kunihiko
    Kanda, Gaku
    Yokoi, Kiminobu
    Teranishi, Jin
    Aoki, Kousuke
    Chimura, Misato
    Yamada, Shinichiro
    Taniguchi, Yasuyo
    Kawai, Hiroya
    Yasaka, Yoshinori
    Yokoyama, Mitsuhiro
    [J]. JOURNAL OF ARRHYTHMIA, 2014, 30 (06) : 515 - 518
  • [9] HYDROTHORAX - COMPLICATION OF INTRA-CARDIAC PLACEMENT OF UMBILICAL VENOUS CATHETER
    KULKARNI, PB
    DORAND, RD
    [J]. JOURNAL OF PEDIATRICS, 1979, 94 (05): : 813 - 815
  • [10] INTRA-CARDIAC ELECTROCARDIOGRAPHY
    SEIPEL, L
    [J]. ZEITSCHRIFT FUR KARDIOLOGIE, 1978, 67 (03): : 187 - 187