Quantification of ethanol in plasma by electrochemical detection with an unmodified screen printed carbon electrode

被引:8
|
作者
Tian, Gang [1 ]
Zhang, Xiao-Qing [1 ]
Zhu, Ming-Song [1 ]
Zhang, Zhong [2 ]
Shi, Zheng-Hu [1 ]
Ding, Min [1 ]
机构
[1] Chongqing Med Univ, Coll Lab Med, Minist Educ China, Key Lab Clin Lab Diagnost, Chongqing 400016, Peoples R China
[2] Chongqing Police Bur, Ctr Evidence Identificat, Chongqing, Peoples R China
来源
SCIENTIFIC REPORTS | 2016年 / 6卷
关键词
MASS SPECTROMETRY METHOD; GAS-CHROMATOGRAPHY; ALCOHOL; BLOOD; NANOBIOCOMPOSITE; ACETALDEHYDE; FABRICATION; SERUM; NADH;
D O I
10.1038/srep23569
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Simple, rapid and accurate detection of ethanol concentration in blood is very crucial in the diagnosis and management of potential acute ethanol intoxication patients. A novel electrochemical detection method was developed for the quantification of ethanol in human plasma with disposable unmodified screen-printed carbon electrode (SPCE) without sample preparation procedure. Ethanol was detected indirectly by the reaction product of ethanol dehydrogenase (ADH) and cofactor nicotinamide adenine dinucleotide (NAD(+)). Method validation indicated good quantitation precisions with intra-day and inter-day relative standard deviations of <= 9.4% and 8.0%, respectively. Ethanol concentration in plasma is linear ranging from 0.10 to 3.20 mg/mL, and the detection limit is 40.0 mu g/mL (S/N > 3). The method shows satisfactory correlation with the reference method of headspace gas chromatography in twenty human plasma samples (correlation coefficient 0.9311). The proposed method could be applied to diagnose acute ethanol toxicity or ethanol-related death.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Quantification of ethanol in plasma by electrochemical detection with an unmodified screen printed carbon electrode
    Gang Tian
    Xiao-Qing Zhang
    Ming-Song Zhu
    Zhong Zhang
    Zheng-Hu Shi
    Min Ding
    [J]. Scientific Reports, 6
  • [2] Quantification of Myoinositol in Serum by Electrochemical Detection with an Unmodified Screen-Printed Carbon Electrode
    Jin, Xinrui
    Zhao, Yuanqing
    Gu, Xiujuan
    Zhong, Min
    Kong, Xin
    Li, Guangrong
    Tian, Gang
    Liu, Jinbo
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2022, 2022
  • [3] Screen-printed carbon electrode for the electrochemical detection of conjugated bilirubin
    Resmi, P. E.
    Raveendran, Jeethu
    Suneesh, P. V.
    Ramanchandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    [J]. MATERIALS LETTERS, 2021, 304
  • [4] Trans-resveratrol electrochemical detection using portable device based on unmodified screen-printed electrode
    Klein, Rosecler Scacchetti
    Taniguchi, Maiara Mitiko
    dos Santos, Patricia Daniele
    Bonafe, Elton Guntendorfer
    Martins, Alessandro Francisco
    Monteiro, Johny Paulo
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 207
  • [5] Development of an unmodified screen-printed graphene electrode for nonenzymatic histamine detection
    Nakthong, Prangthip
    Kondo, Takeshi
    Chailapakul, Orawon
    Siangproh, Weena
    [J]. ANALYTICAL METHODS, 2020, 12 (44) : 5407 - 5414
  • [6] Unmodified screen-printed silver electrode for facile detection of organophosphorus pesticide
    Tang, Wenzhi
    Fan, Kai
    Zhou, Jiazheng
    Wu, Jian
    Ji, Feng
    [J]. IONICS, 2015, 21 (02) : 587 - 592
  • [7] An Electrochemical Detection of Vanillin Based on Carbon Black Nanoparticles Modified Screen Printed Carbon Electrode
    Kutty, Muthu
    Settu, Ramki
    Chen, Shen-Ming
    Chen, Tse-Wei
    Tseng, Tien-Wen
    Hatamleh, Ashraf A.
    Yu, Jaysan
    Yu, Richard
    Huang, Chih-Ching
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (07): : 5972 - 5983
  • [8] Unmodified screen-printed silver electrode for facile detection of organophosphorus pesticide
    Wenzhi Tang
    Kai Fan
    Jiazheng Zhou
    Jian Wu
    Feng Ji
    [J]. Ionics, 2015, 21 : 587 - 592
  • [9] Electrochemical determination of riboflavin in pharmaceuticals using unmodified screen printed carbon electrodes
    Skender Radoniqi
    Qëndresa Spahiu
    Eda Mehmeti
    Kurt Kalcher
    Shpend Dragusha
    [J]. Analytical Sciences, 2024, 40 : 681 - 689
  • [10] Electrochemical determination of riboflavin in pharmaceuticals using unmodified screen printed carbon electrodes
    Radoniqi, Skender
    Spahiu, Qendresa
    Mehmeti, Eda
    Kalcher, Kurt
    Dragusha, Shpend
    [J]. ANALYTICAL SCIENCES, 2024, 40 (04) : 681 - 689