Transmittance optimization for high sensitivity ozone concentration measurement

被引:3
|
作者
Marcus, Tay Ching En [1 ]
Ibrahim, Mohd Haniff [1 ]
Ngajikin, Nor Hafizah [1 ]
Azmi, Asrul Izam [1 ]
机构
[1] Univ Teknol Malaysia, Fac Elect Engn, Dept Commun Engn, Skudai 81310, Johor, Malaysia
来源
关键词
Beer-Lambert law; Optimization; Ozone sensor; Sensitivity; Transmittance; Wavelength; ABSORPTION CROSS-SECTION; BEER-LAMBERT LAW; ULTRA-VIOLET;
D O I
10.1016/j.snb.2016.02.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In ultraviolet absorption spectroscopy, sensitivity of ozone concentration measurement is low when transmittance is too high or too low. This is because transmittance of light influences sensitivity of measurement. Here, we derive a new equation based on Beer-Lambert law to determine sensitivity of sensor. The proposed equation is applied to optimize transmittance for high sensitivity ozone concentration measurement. The proposed equation is validated by comparison to Twyman-Lothian equation, theoretical calculation, spectralcalc.com simulation and experiment. Simulation and experimental results show high sensitivity of measurement when ozone is sampled at optimum transmittance. (c) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:528 / 533
页数:6
相关论文
共 50 条
  • [1] Optical path length and absorption cross section optimization for high sensitivity ozone concentration measurement
    Marcus, Tay Ching En
    Ibrahim, Mohd Haniff
    Ngajikin, Nor Hafizah
    Azmi, Asrul Izam
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 570 - 575
  • [2] MEASUREMENT OF OZONE CONCENTRATION
    THELAMON, C
    [J]. POLYMER TESTING, 1982, 3 (02) : 143 - 150
  • [3] A concentration and measurement of atmospheric ozone
    Paneth, FA
    Edgar, JL
    [J]. NATURE, 1938, 142 : 571 - 571
  • [4] A concentration and measurement of atmospheric ozone
    Reynolds, WC
    [J]. NATURE, 1938, 142 : 571 - 571
  • [5] AUTOMATED MEASUREMENT OF AQUEOUS OZONE CONCENTRATION
    DARBY, JL
    CHANG, DPY
    COGGIN, PS
    CHUNG, HK
    DASGUPTA, PK
    [J]. PROCESS CONTROL AND QUALITY, 1995, 6 (04): : 229 - 243
  • [6] UNCERTAINTY EVALUATION THAT AFFECTS THE MEASUREMENT OF A CONCENTRATION FROM TRANSMITTANCE VALUE
    LUNA, MF
    BORZANI, W
    [J]. ARQUIVOS DE BIOLOGIA E TECNOLOGIA, 1991, 34 (01): : 83 - 93
  • [7] AUTOMATIC-MEASUREMENT OF OZONE CONCENTRATION IN WATER
    ARDZHANOV, IV
    GRITSENKO, VS
    DOMOSTROEVA, NG
    KONOPLEVA, GP
    SHAGINYAN, LB
    [J]. MEASUREMENT TECHNIQUES, 1976, 19 (05) : 743 - 745
  • [8] The measurement of ozone concentration by kazan radar observations
    Karpov, A
    Konnov, A
    [J]. PROCEEDINGS OF THE METEOROIDS 2001 CONFERENCE, 2001, 495 : 377 - 379
  • [9] Guideline for measurement of ozone concentration in the process gas from an ozone generator
    Rakness, K
    Gordon, G
    Langlais, B
    Masschelein, W
    Matsumoto, N
    Richard, Y
    Robson, CM
    Somiya, I
    [J]. OZONE-SCIENCE & ENGINEERING, 1996, 18 (03) : 209 - 229
  • [10] Radon concentration measurement with a high-sensitivity radon detector at the Yemilab
    Seo, Kyung Min
    Kim, Hyunsoo
    Kim, Yeong Duk
    Lee, Hye Young
    Lee, Jaison
    Lee, Moo Hyun
    So, Jungho
    Yoon, Sang Cheol
    Yoon, Young Soo
    [J]. JOURNAL OF INSTRUMENTATION, 2024, 19 (05):