Validity and reliability of head posture measurement using Microsoft Kinect

被引:13
|
作者
Oh, Baek-Lok [1 ]
Kim, Jongmin [2 ]
Kim, Jongshin [3 ]
Hwang, Jeong-Min [1 ]
Lee, Jehee [2 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Coll Med, Dept Ophthalmol, Seognam 463707, Gyeonggi Do, South Korea
[2] Seoul Natl Univ, Sch Comp Sci & Engn, Seoul 151742, South Korea
[3] Korea Adv Inst Sci & Technol, Grad Sch Med Sci & Engn, Taejon 305701, South Korea
基金
新加坡国家研究基金会;
关键词
INFANTILE NYSTAGMUS SYNDROME; REHABILITATION; CHILDREN; CAMERA;
D O I
10.1136/bjophthalmol-2014-305095
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To investigate the validity and reliability of Microsoft Kinect-based head tracker (KHT) for measuring head posture. Methods Considering the cervical range of motion (CROM) as a reference, one-dimensional and three-dimensional (1D and 3D) head postures of 12 normal subjects (28-58 years of age; 6 women and 6 men) were obtained using the KHT. The KHT was validated by Pearson's correlation coefficient and intraclass correlation (ICC) coefficient. Test-retest reliability of the KHT was determined by its 95% limit of agreement (LoA) with the Bland-Altman plot. Face recognition success rate was evaluated for each head posture. Results Measurements of 1D and 3D head posture performed using the KHT were very close to those of the CROM with correlation coefficients of 0.99 and 0.97 (p<0.05), respectively, as well as with an ICC of >0.99 and 0.98, respectively. The reliability tests of the KHT in terms of 1D and 3D head postures had 95% LoA angles of approximately +/- 2.5 degrees and +/- 6.5 degrees, respectively. Conclusions The KHT showed good agreement with the CROM and relatively favourable test-retest reliability. Considering its high performance, convenience and low cost, KHT could be clinically used as a head posture-measuring system.
引用
收藏
页码:1560 / 1564
页数:5
相关论文
共 50 条
  • [1] Reliability and validity of the Microsoft Kinect for evaluating static foot posture
    Benjamin F Mentiplay
    Ross A Clark
    Alexandra Mullins
    Adam L Bryant
    Simon Bartold
    Kade Paterson
    [J]. Journal of Foot and Ankle Research, 6
  • [2] Reliability and validity of the Microsoft Kinect for evaluating static foot posture
    Mentiplay, Benjamin F.
    Clark, Ross A.
    Mullins, Alexandra
    Bryant, Adam L.
    Bartold, Simon
    Paterson, Kade
    [J]. JOURNAL OF FOOT AND ANKLE RESEARCH, 2013, 6
  • [3] Reliability and validity of an innovative method of ROM measurement using Microsoft Kinect V2
    Kosesoy, Irfan
    Oz, Cemil
    Aslan, Fatih
    Koroglu, Fahri
    Yigilitas, Mustafa
    [J]. PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2018, 24 (05): : 915 - 920
  • [4] Validity of the Microsoft Kinect for measurement of neck angle: comparison with electrogoniometry
    Allahyari, Teimour
    Samani, Ali Sahraneshin
    Khalkhali, Hamid-Reza
    [J]. INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS, 2017, 23 (04) : 524 - 532
  • [5] PostureCheck: Posture Modeling for Exercise Assessment Using the Microsoft Kinect
    Saraee, Elham
    Singh, Saurabh
    Joshi, Ajjen
    Betke, Margrit
    [J]. 2017 INTERNATIONAL CONFERENCE ON VIRTUAL REHABILITATION (ICVR), 2017,
  • [6] The concurrent validity and intrarater reliability of the Microsoft Kinect to measure thoracic kyphosis
    Quek, June
    Brauer, Sandra G.
    Treleaven, Julia
    Clark, Ross A.
    [J]. INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2017, 40 (03) : 279 - 284
  • [7] The Validity and Reliability of the Microsoft Kinect for Measuring Trunk Compensation during Reaching
    Foreman, Matthew H.
    Engsberg, Jack R.
    [J]. SENSORS, 2020, 20 (24) : 1 - 15
  • [8] A Brief Review on the Validity and Reliability of Microsoft Kinect Sensors for Functional Assessment Applications
    Rodrigo Diaz-Monterrosas, Pablo
    Posada-Gomez, Ruben
    Martinez-Sibaja, Albino
    Alfonso Aguilar-Lasserre, Alberto
    Juarez-Martinez, Ulises
    Carlos Trujillo-Caballero, Juan
    [J]. ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2018, 18 (01) : 131 - 136
  • [9] Validity and Reliability of Upper Limb Functional Assessment Using the Microsoft Kinect V2 Sensor
    Cai, Laisi
    Ma, Ye
    Xiong, Shuping
    Zhang, Yanxin
    [J]. APPLIED BIONICS AND BIOMECHANICS, 2019, 2019
  • [10] Clinical measurement of craniovertebral angle by electronic head posture instrument: A test of reliability and validity
    Lau, Herman Mun Cheung
    Chiu, Thomas Tai Wing
    Lam, Tai-Hing
    [J]. MANUAL THERAPY, 2009, 14 (04) : 363 - 368