ESTIMATE OF BIRTH WEIGHT USING TWO- AND THREE-DIMENSIONAL ULTRASONOGRAPHY

被引:9
|
作者
Machado Nardozza, Luciano Marcondes [1 ]
Araujo Junior, Edward [1 ]
Vieira, Marcio Fragoso [1 ]
Rolo, Liliam Cristine [1 ]
Moron, Antonio Fernandes [1 ]
机构
[1] Univ Fed Sao Paulo, Escola Paulista Med, Dept Obstet, UNIFESP EPM, Sao Paulo, Brazil
来源
关键词
Fetal weight; Imaging; Three-Dimensional; Ultrasonography; PREDICTING FETAL WEIGHT; LIMB VOLUME; ULTRASOUND; GROWTH; ABDOMEN; THIGH; BODY; HEAD;
D O I
10.1590/S0104-42302010000200020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ESTIMATE OF BIRTH WEIGHT USING TWO- AND THREE-DIMENSIONAL ULTRASONOGRAPHY OBJECTIVE. Assess and compare accuracy of birth weight prediction using a combination of two-dimensional (abdominal circumference - AC and femur length - FL) and three-dimensional parameters (fetal arm -VolArm and thigh -VolTh volumes). METHODS. A cross sectional study was carried out involving 78 singleton, live, euploid fetuses without structural malformations born within 48 hours after ultrasonography. VolArm and VolTh were obtained by three-dimensional ultrasound using the multiplanar mode at 5 mm intervals. AC and FL were measured by two-dimensional ultrasound. Linear and polynomial regressions were calculated to determine the best formula to predict birth weight using VolArm, VolTh, CA and FL. ANOVA was used to compare errors in birth weight prediction using this formula and those obtained using the Shepard and Hadlock formulae. RESULTS. The best formula for prediction of birth weight was a simple linear regression (Weight = -1486.1 + 60.5AC + 140.57FL + 16.6 VolArm + 4.8VolTh), R2= 0.932. The error (E), absolute error (AE), percent error (PE) and absolute percent error (APE) for this new formula were 0 g, 0.2%, 112.2 g and 3.7%. This new formula had smaller E, AE, PE and APE than the Shepard formula and smaller AE and APE than Hadlock 's formula. CONCLUSION. A formula using VolArm, VolTh, AC and FL was more accurate for prediction of birth weight than formulae using only two-dimensional parameters. [Rev Assoc Med Bras 2010; 56(2): 204-8]
引用
收藏
页码:204 / 208
页数:5
相关论文
共 50 条
  • [1] Birth-weight prediction by two- and three-dimensional ultrasound imaging
    Bennini, J. R.
    Marussi, E. F.
    Barini, R.
    Faro, C.
    Peralta, C. F. A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 35 (04) : 426 - 433
  • [2] Prenatal diagnosis of posterior mediastinal lymphangioma by two- and three-dimensional ultrasonography
    Ruano, R.
    Takashi, E.
    Schultz, R.
    Zugaib, M.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (06) : 697 - 700
  • [3] The Role of Two- and Three-Dimensional Dynamic Ultrasonography in Pelvic Organ Prolapse
    Dietz, Hans Peter
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2010, 17 (03) : 282 - 294
  • [4] Two- or three-dimensional ultrasonography: which is the best predictor of pulmonary hypoplasia?
    Vergani, Patrizia
    Andreani, Marianna
    Greco, Massimiliano
    Farina, Giuliano
    Fedeli, Tiziana
    Cuttin, Serena
    PRENATAL DIAGNOSIS, 2010, 30 (09) : 834 - 838
  • [5] Two- and three-dimensional transvaginal ultrasonography for diagnosis of adenomyosis of the inner myometrium
    Rasmussen, Christina K.
    Hansen, Estrid S.
    Ernst, Erik
    Dueholm, Margit
    REPRODUCTIVE BIOMEDICINE ONLINE, 2019, 38 (05) : 750 - 760
  • [6] Birth weight prediction by three-dimensional ultrasonography - Fractional limb volume
    Lee, W
    Deter, RL
    Ebersole, JD
    Huang, R
    Blanckaert, K
    Romero, R
    JOURNAL OF ULTRASOUND IN MEDICINE, 2001, 20 (12) : 1283 - 1292
  • [7] Two- and three-dimensional surfaces
    Hauck, J
    Mika, K
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2002, 216 (11): : 1281 - 1293
  • [8] Prediction of birth weight in twin pregnancies using fractional limb volumes by three-dimensional ultrasonography
    Correa, Vivian Melo
    Araujo Junior, Edward
    Braga, Antonio
    Elito Junior, Julio
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2020, 33 (21): : 3652 - 3657
  • [9] Comparison of two- and three-dimensional ultrasonography in lung volume measurement of normal fetuses
    Araujo, Edward, Jr.
    Machado Nardozza, Luciano Marcondes
    Pires, Claudio Rodrigues
    Guimaraes Filho, Helio Antonio
    Moron, Antonio Fernandes
    JOURNAL OF PERINATAL MEDICINE, 2007, 35 (05) : 415 - 421
  • [10] Two- and three-dimensional image rotation using the FFT
    Cox, RW
    Tong, RQ
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 1999, 8 (09) : 1297 - 1299