Tracking errors in a prototype real-time tumour tracking system

被引:30
|
作者
Sharp, GC [1 ]
Jiang, SB
Shimizu, S
Shirato, H
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Hokkaido Univ, Sch Med, Dept Radiat Med, Sapporo, Hokkaido 060, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 23期
关键词
D O I
10.1088/0031-9155/49/23/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In motion-compensated radiation therapy, radio-opaque markers can be implanted in or near a tumour and tracked in real-time using fluoroscopic imaging. Tracking these implanted markers gives highly accurate position information, except when tracking fails due to poor or ambiguous imaging conditions. This study investigates methods for automatic detection of tracking errors, and assesses the frequency and impact of tracking errors on treatments using the prototype real-time tumour tracking system. We investigated four indicators for automatic detection of tracking errors. and found that the, distance between corresponding rays was most effective. We also found that tracking errors cause a loss of gating efficiency of between 7.6 and 10.2%. The incidence of treatment beam delivery during tracking errors was estimated at between 0.8% and 1.25%.
引用
收藏
页码:5347 / 5356
页数:10
相关论文
共 50 条
  • [1] Tracking errors in a prototype real-time tumor tracking system
    Sharp, G
    Jiang, S
    Shimizu, S
    Shirato, H
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1760 - 1760
  • [2] REAL-TIME RESPIRATORY TUMOUR TRACKING BY A ROBOTIC SYSTEM
    Hoogeman, M.
    Nuyttens, J.
    Van Zyp, N. van der Voort
    Levendag, P.
    Heijmen, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S82 - S82
  • [3] PRE-PROTOTYPE REAL-TIME VIDEO TRACKING SYSTEM
    BLACK, RJ
    WHITNEY, JT
    GILBERT, AL
    [J]. IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1976, 12 (03) : 416 - 417
  • [4] Real-time tumour-tracking radiotherapy
    Shirato, H
    Shimizu, S
    Shimizu, T
    Nishioka, T
    Miyasaka, K
    [J]. LANCET, 1999, 353 (9161): : 1331 - 1332
  • [5] A Real-Time Eye Tracking System for Predicting and Preventing Postcompletion Errors
    Ratwani, Raj M.
    Trafton, J. Gregory
    [J]. HUMAN-COMPUTER INTERACTION, 2011, 26 (03): : 205 - 245
  • [6] Real-Time MR Tumour Tracking and Dose Adaptation
    Yun, J.
    Robinson, D.
    MacKenzie, M.
    Rathee, S.
    Murray, B.
    Fallone, B.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [7] Real-Time MR Tumour Tracking and Dose Adaptation
    Yun, J.
    Robinson, D.
    MacKenzie, M.
    Rathee, S.
    Murray, B.
    Fallone, B. G.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4301 - 4301
  • [8] Real-time tracking of tumour positions for precision irradiation
    Kirsch, S
    Boksberger, HU
    Greuter, U
    Schilling, C
    Seiler, PG
    [J]. ADVANCES IN HADRONTHERAPY, 1997, 1144 : 269 - 274
  • [9] REAL-TIME VIDEO TRACKING SYSTEM
    GILBERT, AL
    GILES, MK
    FLACHS, GM
    ROGERS, RB
    U, YH
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1980, 2 (01) : 47 - 56
  • [10] REAL-TIME VIDEO TRACKING SYSTEM
    GILBERT, AL
    GILES, MK
    FLACHS, GM
    ROGERS, RB
    U, YH