Quantifying Effect of Onabotulinum Toxin A on Passive Muscle Stiffness in Children with Cerebral Palsy Using Ultrasound Shear Wave Elastography

被引:31
|
作者
Brandenburg, Joline E. [1 ,2 ,3 ]
Eby, Sarah F. [4 ]
Song, Pengfei [5 ]
Bamlet, William R. [6 ]
Sieck, Gary C. [7 ]
An, Kai-Nan [7 ,8 ]
机构
[1] Mayo Clin, Dept Phys Med & Rehabil, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Neurol, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Pediat & Adolescent Med, Rochester, MN 55905 USA
[4] Mayo Clin, Mayo Grad Sch, Med Scientist Training Program, Coll Med, Rochester, MN 55905 USA
[5] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[6] Mayo Clin, Dept Hlth Sci Res, Rochester, MN 55905 USA
[7] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
[8] Mayo Clin, Div Orthoped Res, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
Cerebral Palsy; Ultrasound Imaging; Elastography; Muscles; NEUROMUSCULAR BLOCKADE; SKELETAL-MUSCLE; ASHWORTH SCALE; TARDIEU SCALE; RELIABILITY; SPASTICITY; CONTRACTURES; MANAGEMENT;
D O I
10.1097/PHM.0000000000000907
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective A pilot study was conducted to longitudinally quantify effect of onabotulinum toxin A (BoNT-A) on passive muscle properties in children with cerebral palsy using ultrasound shear wave elastography. Design This was a prospective longitudinal cohort study. Results Between 1 and 3 mos post-BoNT-A, a significant improvement in the shear modulus of the lateral gastrocnemius was found at 10-degrees plantar flexion (PF) (-7.57 [-10.98, -5.07], P = 0.02) and 0-degrees PF (-14.74 [-18.21, -9.38], P = 0.03). There was a notable, but nonsignificant, difference in shear modulus at 20-degrees PF, 10-degrees PF, and 0-degrees PF between pre-BoNT-A and 1 mo post-BoNT-A. Pre-BoNT-A shear modulus was not significantly different from 3 mos post-BoNT-A at all foot positions. No significant differences in ankle passive range of motion or spasticity were found. Conclusion Despite no significant change in ankle range of motion or spasticity, shear wave elastography was able to detect a difference in lateral gastrocnemius passive muscle properties in children with cerebral palsy after BoNT-A injections. The difference in passive muscle properties resolved by 3 mos post-BoNT-A.
引用
收藏
页码:500 / 506
页数:7
相关论文
共 50 条
  • [1] Quantifying passive muscle stiffness in children with and without cerebral palsy using ultrasound shear wave elastography
    Brandenburg, Joline E.
    Eby, Sarah F.
    Song, Pengfei
    Kingsley-Berg, Shirley
    Bamlet, William
    Sieck, Gary C.
    An, Kai-Nan
    [J]. DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2016, 58 (12): : 1288 - 1294
  • [2] Feasibility and Reliability of Quantifying Passive Muscle Stiffness in Young Children by Using Shear Wave Ultrasound Elastography
    Brandenburg, Joline E.
    Eby, Sarah F.
    Song, Pengfei
    Zhao, Heng
    Landry, Bradford W.
    Kingsley-Berg, Shirley
    Bamlet, William R.
    Chen, Shigao
    Sieck, Gary C.
    An, Kai-Nan
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (04) : 663 - 670
  • [3] Use of Shear Wave Elastography for Quantitative Assessment of Muscle Stiffness After Botulinum Toxin Injection in Children With Cerebral Palsy
    Bertan, Huseyin
    Oncu, Julide
    Vanli, Ersin
    Alptekin, Kerem
    Sahillioglu, Ali
    Kuran, Banu
    Yilmaz, Figen
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (12) : 2327 - 2337
  • [4] Use of ultrasound shear wave to measure muscle stiffness in children with cerebral palsy
    Vola E.A.
    Albano M.
    Di Luise C.
    Servodidio V.
    Sansone M.
    Russo S.
    Corrado B.
    Servodio Iammarrone C.
    Caprio M.G.
    Vallone G.
    [J]. Journal of Ultrasound, 2018, 21 (3) : 241 - 247
  • [5] The utility of shear wave elastography in the evaluation of muscle stiffness in patients with cerebral palsy after botulinum toxin A injection
    Nurullah Dağ
    Mahi Nur Cerit
    Halit Nahit Şendur
    Murat Zinnuroğlu
    Bilge Nur Muşmal
    Emetullah Cindil
    Suna Özhan Oktar
    [J]. Journal of Medical Ultrasonics, 2020, 47 : 609 - 615
  • [6] The utility of shear wave elastography in the evaluation of muscle stiffness in patients with cerebral palsy after botulinum toxin A injection
    Dag, Nurullah
    Cerit, Mahi Nur
    Sendur, Halit Nahit
    Zinnuroglu, Murat
    Musmal, Bilge Nur
    Cindil, Emetullah
    Oktar, Suna ozhan
    [J]. JOURNAL OF MEDICAL ULTRASONICS, 2020, 47 (04) : 609 - 615
  • [7] Quantifying cervical and axioscapular muscle stiffness using shear wave elastography
    Xie, Yanfei
    Thomas, Lucy
    Hug, Francois
    Johnston, Venerina
    Coombes, Brooke K.
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2019, 48 : 94 - 102
  • [8] Use of shear wave ultrasound elastography to quantify muscle properties in cerebral palsy
    Lee, Sabrina S. M.
    Gaebler-Spira, Deborah
    Zhang, Li-Qun
    Rymer, William Z.
    Steele, Katherine M.
    [J]. CLINICAL BIOMECHANICS, 2016, 31 : 20 - 28
  • [9] Stiffness of individual quadriceps muscle assessed using ultrasound shear wave elastography during passive stretching
    Xu, Jingfei
    Hug, Francois
    Fu, Siu Ngor
    [J]. JOURNAL OF SPORT AND HEALTH SCIENCE, 2018, 7 (02) : 245 - 249
  • [10] Stiffness of individual quadriceps muscle assessed using ultrasound shear wave elastography during passive stretching
    Jingfei Xu
    Fran?ois Hug
    Siu Ngor Fu
    [J]. Journal of Sport and Health Science, 2018, 7 (02) : 245 - 249