Radiation Dose Reduction by Using CT with Iterative Model Reconstruction in Patients with Pulmonary Invasive Fungal Infection

被引:25
|
作者
Yan, Chenggong [1 ]
Xu, Jun [2 ]
Liang, Chunyi [1 ]
Wei, Qi [2 ]
Wu, Yuankui [1 ]
Xiong, Wei [1 ]
Zheng, Huan [1 ]
Xu, Yikai [1 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Dept Med Imaging Ctr, 1838 Guangzhou Ave North, Guangzhou 510515, Guangdong, Peoples R China
[2] Southern Med Univ, Nanfang Hosp, Dept Hematol, 1838 Guangzhou Ave North, Guangzhou 510515, Guangdong, Peoples R China
关键词
INTERSTITIAL LUNG-DISEASE; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; THORACIC CT; BODY CT; CHEST; DIAGNOSIS; DETECTABILITY; PERFORMANCE; ALGORITHMS;
D O I
10.1148/radiol.2018172107
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the diagnostic quality of reduced radiation dose computed tomography (CT) with iterative model reconstruction (IMR) versus that of conventional low-dose CT in patients with pulmonary invasive fungal infection. Materials and Methods: This prospective observational study included 48 patients (mean age +/- standard deviation, 39.9 years +/- 11.3) known to have or suspected of having pulmonary invasive fungal infection between October 2016 and July 2017. Patients underwent CT with IMR (at 80 kV with 20 mA) immediately after low-dose CT (at 80 kV with automatic exposure control). Images were reconstructed by using a hybrid iterative reconstruction (HIR) algorithm and IMR. Two radiologists independently assessed subjective image quality, noise, and visibility of normal and abnormal findings by using a five-point scale. Objective measurements, including image noise, contrast-to-noise ratio (CNR), and corresponding figure of merit (FOM), were compared by using repeated-measures analysis of variance with Bonferroni post hoc tests for multiple comparisons. Results: The mean effective dose was 0.3 mSv +/- 0.3 for CT with IMR and 0.7 mSv +/- 0.2 for low-dose CT (P<.01). When the image noise and CNR were normalized to the effective dose, CT images obtained with IMR had significantly higher FOM than did other image series (P<.0001). Subjectively, visibility of CT features of invasive fungal infection on CT scans reconstructed with IMR was rated as noninferior to that on low-dose CT scans reconstructed with HIR, except for the halo sign. Conclusion: CT with IMR had approximately 60% dose reduction compared with conventional low-dose CT, with reduced noise and improved depiction of abnormal findings, in patients with pulmonary invasive fungal infection. (c) RSNA, 2018
引用
收藏
页码:285 / 292
页数:8
相关论文
共 50 条
  • [1] Radiation Dose Reduction in Paranasal Sinus CT Using Model-Based Iterative Reconstruction
    Hoxworth, J. M.
    Lal, D.
    Fletcher, G. P.
    Patel, A. C.
    He, M.
    Paden, R. G.
    Hara, A. K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (04) : 644 - 649
  • [2] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Niesten, Joris M.
    van der Schaaf, Irene C.
    Riordan, Alan J.
    de Jong, Hugo W. A. M.
    Horsch, Alexander D.
    Eijspaart, Daniel
    Smit, Ewoud J.
    Mali, Willem P. T. M.
    Velthuis, Birgitta K.
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 484 - 493
  • [3] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Joris M. Niesten
    Irene C. van der Schaaf
    Alan J. Riordan
    Hugo W. A. M. de Jong
    Alexander D. Horsch
    Daniel Eijspaart
    Ewoud J. Smit
    Willem P. T. M. Mali
    Birgitta K. Velthuis
    European Radiology, 2014, 24 : 484 - 493
  • [4] Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Shenoy-Bhangle, Anuradha S.
    Saini, Aashna
    Gervais, Debra A.
    Westra, Sjirk J.
    Thrall, James H.
    RADIOLOGY, 2012, 263 (02) : 537 - 546
  • [5] Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction
    Yasaka, Koichiro
    Katsura, Masaki
    Akahane, Masaaki
    Sato, Jiro
    Matsuda, Izuru
    Ohtomo, Kuni
    SPRINGERPLUS, 2013, 2 : 1 - 9
  • [6] Investigation of Renal CT Dose Reduction by Using Model Based Iterative Reconstruction
    Page, L.
    Kundra, V.
    Rong, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] CT radiation dose reduction in patients with total hip arthroplasties using model-based iterative reconstruction and orthopaedic metal artefact reduction
    Ruud H. H. Wellenberg
    Jochen A. C. van Osch
    Henk J. Boelhouwers
    Mireille A. Edens
    Geert J. Streekstra
    Harmen B. Ettema
    Martijn F. Boomsma
    Skeletal Radiology, 2019, 48 : 1775 - 1785
  • [8] CT radiation dose reduction in patients with total hip arthroplasties using model-based iterative reconstruction and orthopaedic metal artefact reduction
    Wellenberg, Ruud H. H.
    van Osch, Jochen A. C.
    Boelhouwers, Henk J.
    Edens, Mireille A.
    Streekstra, Geert J.
    Ettema, Harmen B.
    Boomsma, Martijn F.
    SKELETAL RADIOLOGY, 2019, 48 (11) : 1775 - 1785
  • [9] Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms
    Weir, V.
    Zhang, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3368 - 3368
  • [10] Radiation Dose Reduction in Temporal Bone CT with Iterative Reconstruction Technique
    Niu, Y. T.
    Mehta, D.
    Zhang, Z. R.
    Zhang, Y. X.
    Liu, Y. F.
    Kang, T. L.
    Xian, J. F.
    Wang, Z. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1020 - 1026